510(k) · Cleared
ClearedMD2000B Vital Sign Monitor, Model MD2000B
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Beijing Choice Electronic Technololgy Co., Ltd. · MWI Monitor, Physiological, Patient (Without Arrhythmia Detection Or Alarms)
Cleared on Jul 9, 2010 as substantially equivalent to K063055 (Shenzhen Mindray Bio-Medical Electronics Co., Ltd., 2006) after a 115-day review. Its family tree reaches back 8 generations to 1994. 2 later devices descend from it.
- Decided
- Jul 9, 2010
- Review
- 115 days
- Class
- Class II
- Product code
- MWI
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 8 generations to K933143 (1994). 41 ancestors in all, the oldest K842616 (1984). 2 later devices descend from it, 2 citing it directly.
- Root · 8 generations backK933143 Model Eli 300 ElectrocardiographMortara Instrument, Inc. · 1994
- 7 generations backK962970 Spacelabs Medical 12-Lead Diagnostic Ecg Analysis OptionSpacelabs Medical, Inc. · 1997
- 6 generations backK972502 Spacelabs Medical Integrated Multiparameter Module 90496Spacelabs Medical, Inc. · 1998 · Recalled
- 5 generations backK993531 Passport 2 Vital Signs Monitor, Model 0998-00-0170-XXDatascope Corp. · 2000 · Recalled
- 4 generations backK032733 PM-8000 Patient Monitor, Model 8000Shenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2004
- 3 generations backK043348 Modification to PM-8000 Patient MonitorShenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2005
- 2 generations backK060281 VS-800 Vital Signs MonitorShenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2006
- 1 generation backK063055 VS-800 Vital Signs MonitorShenzhen Mindray Bio-Medical Electronics Co., Ltd. · 2006
- This deviceK100740 MD2000B Vital Sign Monitor, Model MD2000BBeijing Choice Electronic Technololgy Co., Ltd. · 2010
- Descendant · cites it directly · 0 of its ownK211754 Vital Signs MonitorBeijing Choice Electronic Technology Co., Ltd. · 2021
- Descendant · cites it directly · 0 of its ownK130056 Patient MonitorLd Technology, LLC · 2013
Most influential descendants
Showing 2 of 2 · See allView FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −8 | K933143 | Model Eli 300 Electrocardiograph | Mortara Instrument, Inc. | 1994 | — |
| −7 | K962970 | Spacelabs Medical 12-Lead Diagnostic Ecg Analysis Option | Spacelabs Medical, Inc. | 1997 | — |
| −6 | K972502 | Spacelabs Medical Integrated Multiparameter Module 90496 | Spacelabs Medical, Inc. | 1998 | 3 |
| −5 | K993531 | Passport 2 Vital Signs Monitor, Model 0998-00-0170-XX | Datascope Corp. | 2000 | 1 |
| −4 | K032733 | PM-8000 Patient Monitor, Model 8000 | Shenzhen Mindray Bio-Medical Electronics Co., Ltd. | 2004 | — |
| −3 | K043348 | Modification to PM-8000 Patient Monitor | Shenzhen Mindray Bio-Medical Electronics Co., Ltd. | 2005 | — |
| −2 | K060281 | VS-800 Vital Signs Monitor | Shenzhen Mindray Bio-Medical Electronics Co., Ltd. | 2006 | — |
| −1 | K063055 | VS-800 Vital Signs Monitor | Shenzhen Mindray Bio-Medical Electronics Co., Ltd. | 2006 | — |
| 0 (this device) | K100740 | MD2000B Vital Sign Monitor, Model MD2000B | Beijing Choice Electronic Technololgy Co., Ltd. | 2010 | — |
| +1 | K211754 | Vital Signs Monitor | Beijing Choice Electronic Technology Co., Ltd. | 2021 | — |
| +1 | K130056 | Patient Monitor | Ld Technology, LLC | 2013 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1984 | 1 | 0 |
| 1989 | 2 | 0 |
| 1990 | 3 | 0 |
| 1991 | 5 | 0 |
| 1992 | 1 | 0 |
| 1993 | 1 | 0 |
| 1994 | 4 | 0 |
| 1995 | 5 | 0 |
| 1996 | 4 | 0 |
| 1997 | 4 | 0 |
| 1998 | 1 | 0 |
| 1999 | 1 | 0 |
| 2000 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2013 | 1 | 0 |
| 2021 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in MWI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new MWI device
- #1 K230457 Empatica Health Monitoring Platform…score 28.0 · 39 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K063055 | VS-800 Vital Signs MonitorSummary page 2…patients. Predicate Device: VS-800 Vital Signs Monitor K Number: K063055 Device Description: The proposed device, MD2000B Vital Signs Monitor,… | 2006 |
What descends from it? (2)
2 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 16 years and passes through 5 companies; a new generation was cleared every 1.6 years on median.
- 6 of the 41 ancestors have a recall of any class.
- Of its descendants, K211754 (Beijing Choice Electronic Technology Co., Ltd., 2021) has gone furthest, with 0 descendants of its own.
- 3 other devices also cite its predicate K063055.
How does its category compare?
All MWI devicesMWI Monitor, Physiological, Patient (Without Arrhythmia Detection Or Alarms): FDA decisions, review times, recalls and adverse event reports over 20 years. 2010, this device’s year, is highlighted.
FDA decisions per year · MWI
4in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · MWI
247in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · MWI
9so far in 2026, the most since 2007
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · MWI
182in 2025
MAUDE reports naming product code MWI, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 9 | 42 | 1 | 3 |
| 2008 | 9 | 49 | 1 | 3 |
| 2009 | 6 | 112 | 2 | 20 |
| 2010 | 17 | 58 | 2 | 17 |
| 2011 | 11 | 78 | 3 | 16 |
| 2012 | 13 | 104 | 5 | 31 |
| 2013 | 20 | 85 | 3 | 42 |
| 2014 | 16 | 148 | 6 | 30 |
| 2015 | 19 | 127 | 1 | 31 |
| 2016 | 12 | 165 | 0 | 51 |
| 2017 | 13 | 205 | 2 | 85 |
| 2018 | 11 | 217 | 0 | 158 |
| 2019 | 14 | 255 | 4 | 169 |
| 2020 | 8 | 138 | 0 | 110 |
| 2021 | 9 | 161 | 0 | 188 |
| 2022 | 5 | 231 | 2 | 168 |
| 2023 | 8 | 250 | 0 | 179 |
| 2024 | 10 | 202 | 5 | 120 |
| 2025 | 4 | 247 | 0 | 182 |
| 2026 | 6 | 239 | 9 | — |
What is it indicated for?
The vital signs monitor is a portable device indicated for use in non-invasively measuring and displaying functional oxygen saturation of arterial haemoglobin (SpO2), pulse rate(PR), Non-invasive measurement of blood pressure(NIBP) of adult and pediatric patients in hospitals, medical facilities, and sub-acute environments. The vital signs monitor is intended for spot-checking and/or continuous monitoring of patients.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K100740 · printed Nov 3, 2026
Cite this page
510(k) Report. “K100740: MD2000B Vital Sign Monitor, Model MD2000B.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K100740
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026