510(k) Report

510(k) · Cleared

Recalled · Class II · 2012

ABL837 Flex Analyzer

K100777510(k) AbbreviatedCleared Dec 10, 2010267-day reviewClass II21 CFR 862.1120Recalls 2

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Radiometer Medical Aps · CHL Electrode Measurement, Blood-Gases (Pco2, Po2) And Blood Ph

Cleared on Dec 10, 2010 as substantially equivalent to K050423 (Roche Diagnostics, 2005) after a 267-day review. Its family tree reaches back 2 generations to 1987. It has been recalled 2 times.

Decided
Dec 10, 2010
Review
267 days
Class
Class II
Product code
CHL
Recalls
2
Predicates
1

Its longest line of descent runs back 2 generations to K872888 (1987). 3 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 1990: 1 other ancestorK872888 · Ciba Corning 288 PH/Blood Gas System · Ciba Corning Diagnostics Corp. · 1987K050423 · Omni Modular, Omni C and Omni S Analyzer (PH Electrode) · Roche Diagnostics · 2005198519901995200020052010
  1. Root · 2 generations backK872888 Ciba Corning 288 PH/Blood Gas SystemCiba Corning Diagnostics Corp. · 1987
  2. 1 generation backK050423 Omni Modular, Omni C and Omni S Analyzer (PH Electrode)Roche Diagnostics · 2005
  3. This deviceK100777 ABL837 Flex AnalyzerRadiometer Medical Aps · 2010
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K872888Ciba Corning 288 PH/Blood Gas SystemCiba Corning Diagnostics Corp.1987—
−1K050423Omni Modular, Omni C and Omni S Analyzer (PH Electrode)Roche Diagnostics2005—
0 (this device)K100777ABL837 Flex AnalyzerRadiometer Medical Aps2010—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199010
FIG. 1 — Lineage of K100777, 1987–2010Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in CHL? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new CHL device

  1. #1 K252207 ABL90 FLEX PLUS System, safeCLINITUBESscore 14.2 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K050423Omni Modular, Omni C and Omni S Analyzer (PH Electrode)
Summary page 2
…e ABL837 FLEX analyzer with pleural Roche analyzer pH K050423 Indications for use New indication for measuring of pH in Same pleural fluids Blood Gas Me…
Roche Diagnostics2005—

Also cleared against K050423: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jul 5, 2012Class IIZ-2163-2012Software designA customer has reported an error on an ABL8xx configured to a Hospital Information System using the data transfer protocol HL7 version 2.5. If the instrument transmits results to a HIS system and the connection is broken the results are…
Jul 5, 2012Class IIZ-2162-2012Software designA customer has reported an error on an ABL8xx configured to a Hospital Information System using the data transfer protocol HL7 version 2.5. If the instrument transmits results to a HIS system and the connection is broken the results are…

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 23 years and passes through 3 companies; a new generation was cleared every 17.7 years on median.
  • None of the 3 ancestors has a recall.
  • 1 other device also cites its predicate K050423.

How does its category compare?

All CHL devices

CHL Electrode Measurement, Blood-Gases (Pco2, Po2) And Blood Ph: FDA decisions, review times, recalls and adverse event reports over 20 years. 2010, this device’s year, is highlighted.

FDA decisions per year · CHL

1in 2025

2007: 12008: 12010: 12011: 42012: 42013: 52014: 32015: 42016: 32017: 12018: 12020: 42021: 22023: 52024: 12025: 12026 (partial year): 1
2007high 5 (2013) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · CHL

267in 2023

2011: 108 days median2012: 65 days median2013: 152 days median2014: 68 days median2015: 155 days median2016: 306 days median2020: 100 days median2023: 267 days median
2007high 306 (2016) · low 65 (2012)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · CHL

13so far in 2026, the most since 2007

2007: 62008: 52009: 62010: 72011: 12012: 92013: 12014: 12015: 32016: 12017: 12018: 32020: 22023: 42024: 92026 (partial year): 13
2007high 13 (2026) · low 0 (2019)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · CHL

210in 2025

2007: 162008: 402009: 742010: 202011: 502012: 642013: 622014: 932015: 552016: 1182017: 2062018: 1742019: 1412020: 1172021: 1472022: 1382023: 1772024: 1962025: 210
2007high 210 (2025) · low 16 (2007)2025

MAUDE reports naming product code CHL, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—616
20081—540
20090—674
20101—720
20114108150
2012465964
20135152162
2014368193
20154155355
201633061118
20171—1206
20181—3174
20190—0141
202041002117
20212—0147
20220—0138
202352674177
20241—9196
20251—0210
20261—13—

What is it indicated for?

The ABL837 FLEX analyzer is intended for:

in vitro testing of pleural fluid samples for the pH parameter

The pH measurement of pleural fluid can be a clinically usefuil tool in the management of patients with parapneumonic effusions.

Critical values: pH >7.3 is measured in uncomplicated parapneumonic effusions. All pleural effusions with a PH of <7.3 are referred as complicated parapneumonic effusions; they are exudative in nature.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K100777: ABL837 Flex Analyzer.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K100777

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026