510(k) Report

510(k) · Cleared

Cleared

Clearjet

K101094510(k) TraditionalCleared May 17, 201027-day reviewClass II21 CFR 876.1500

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Easyglide, Ltd. · ODC Endoscope Channel Accessory

Cleared on May 17, 2010 as substantially equivalent to K091305 (Easyglide, Ltd., 2009) and 1 other predicate after a 27-day review. Its family tree reaches back 6 generations to 1992.

Decided
May 17, 2010
Review
27 days
Class
Class II
Product code
ODC
Recalls
None
Predicates
2

Its longest line of descent runs back 6 generations to K921244 (1992). 27 ancestors in all, the oldest K822846 (1982). No later device cites it as a predicate yet.

Other ancestors, by year cleared 2007: 1 other ancestor2003: 1 other ancestor2000: 2 other ancestors2002: 1 other ancestor1999: 1 other ancestor1997: 1 other ancestor1996: 5 other ancestors1995: 1 other ancestor1988: 1 other ancestor1994: 3 other ancestors1993: 2 other ancestors1982: 1 other ancestor1992: 1 other ancestorK921244 · Disposable Protective Sheath · Vision-Sciences, Inc. · 1992K961591 · Disposable Endosheath for E-F100 Flexible Nasopharyngoscope · Vision-Sciences, Inc. · 1996K963795 · Vision-Sciences Model B-F100 Bronchoscope with Model BS-F21 Disposable Endosheath · Vision-Sciences, Inc. · 1996K021344 · B-F200 Bronchoscope with BSS-F21 Endosheath System · Vision-Sciences, Inc. · 2002K032688 · Colonosight Model 510B · Sightline Technologies, Ltd. · 2004K091305 · Clearpath · Easyglide, Ltd. · 20091980198519901995200020052010
  1. Root · 6 generations backK921244 Disposable Protective SheathVision-Sciences, Inc. · 1992
  2. 5 generations backK961591 Disposable Endosheath for E-F100 Flexible NasopharyngoscopeVision-Sciences, Inc. · 1996
  3. 4 generations backK963795 Vision-Sciences Model B-F100 Bronchoscope with Model BS-F21…Vision-Sciences, Inc. · 1996
  4. 3 generations backK021344 B-F200 Bronchoscope with BSS-F21 Endosheath SystemVision-Sciences, Inc. · 2002
  5. 2 generations backK032688 Colonosight Model 510BSightline Technologies, Ltd. · 2004
  6. 1 generation backK091305 ClearpathEasyglide, Ltd. · 2009
  7. This deviceK101094 ClearjetEasyglide, Ltd. · 2010
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−6K921244Disposable Protective SheathVision-Sciences, Inc.1992—
−5K961591Disposable Endosheath for E-F100 Flexible NasopharyngoscopeVision-Sciences, Inc.1996—
−4K963795Vision-Sciences Model B-F100 Bronchoscope with Model BS-F21 Disposable…Vision-Sciences, Inc.1996—
−3K021344B-F200 Bronchoscope with BSS-F21 Endosheath SystemVision-Sciences, Inc.2002—
−2K032688Colonosight Model 510BSightline Technologies, Ltd.2004—
−1K091305ClearpathEasyglide, Ltd.2009—
0 (this device)K101094ClearjetEasyglide, Ltd.2010—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198210
198810
199210
199320
199430
199510
199650
199710
199910
200020
200210
200310
200710
FIG. 1 — Lineage of K101094, 1992–2010Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in ODC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new ODC device

  1. #1 K232329 Defendo Fujifilm 700 Single Use Biopsy Valve…score 14.0 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K091305Clearpath
Summary page 1
…KOG - endoscope and/or accessories CFR 876.1500 Device: ClearJet Predicate Devices: K09 1305 - Easy Glide - ClearPath K0070420 - US Endoscope BioShield Device Description: The proposed C…
Easyglide, Ltd.2009—
*K070420Bioshield-Ercp Biopsy Valve, Model 00711138
Summary page 2
…e predicate device, ClearPath K09 1305 or have been tested per ISO 10993. Environment of Use - *Identical to predicates - K09 1305 - EasyGlide ClearPath and K070420 - US Endoscopy Rio-Shield Pa…
United States Endoscopy Group, Inc.20071

Also cleared against K091305: 3 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 18 years and passes through 3 companies; a new generation was cleared every 3.7 years on median.
  • 5 of the 27 ancestors have a recall of any class.
  • 3 other devices also cite its predicate K091305.

How does its category compare?

All ODC devices

ODC Endoscope Channel Accessory: FDA decisions, review times, recalls and adverse event reports over 20 years. 2010, this device’s year, is highlighted.

FDA decisions per year · ODC

6in 2025

2008: 32009: 12010: 42011: 42012: 22015: 22016: 12017: 12018: 22019: 42020: 42021: 62022: 82023: 72024: 82025: 62026 (partial year): 1
2007high 8 (2022) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · ODC

106in 2025

2008: 83 days median2010: 67 days median2011: 143 days median2019: 55 days median2020: 128 days median2021: 181 days median2022: 118 days median2023: 126 days median2024: 95 days median2025: 106 days median
2007high 181 (2021) · low 55 (2019)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · ODC

1so far in 2026, the most since 2007

2026 (partial year): 1
2007high 1 (2026) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · ODC

91in 2025

2012: 12013: 12014: 22015: 32016: 82017: 122018: 172019: 402020: 542021: 522022: 372023: 432024: 1002025: 91
2007high 100 (2024) · low 0 (2007)2025

MAUDE reports naming product code ODC, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
200838300
20091—00
201046700
2011414300
20122—01
20130—01
20140—02
20152—03
20161—08
20171—012
20182—017
2019455040
20204128054
20216181052
20228118037
20237126043
20248950100
20256106091
20261—1—

What is it indicated for?

The ClearJet is an irrigation /biopsy adapter set used to cover the opening to the biopsy/ suction / irrigation channel of Pentax, Olympus and Fuijinon endoscopes. It provides access for endoscopic device passage and exchange, helps maintain sufflation, minimizes leakage of biomaterial from the biopsy port throughout the endoscopic procedure, and provides access, for irrigation.

It is for use only by trained medical personnel located in hospitals, clinics, and doctors' offices.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K101094: Clearjet.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K101094

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026