510(k) Report

510(k) · Cleared

Cleared

Mini-Tong

K101101510(k) TraditionalCleared Jul 23, 201094-day reviewClass II21 CFR 876.1500

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Mini Lap Technologies, Inc. · OCW Endoscopic Tissue Approximation Device

Cleared on Jul 23, 2010 as substantially equivalent to K070686 (Mini Lap Technologies, Inc., 2007) and 3 other predicates after a 94-day review. Its family tree reaches back 2 generations to 1994.

Decided
Jul 23, 2010
Review
94 days
Class
Class II
Product code
OCW
Recalls
None
Predicates
4

Its longest line of descent runs back 2 generations to K944129 (1994). 6 ancestors in all, the oldest K900948 (1990). No later device cites it as a predicate yet.

Other ancestors, by year cleared 2007: 1 other ancestor1990: 2 other ancestors1999: 1 other ancestorK944129 · Imagyn Laparoscopic Instruments · Imagyn Medical, Inc. · 1994K960748 · Modified Hand Instrument Devices · United States Surgical, A Division of Tyco Healthc · 199619901995200020052010
Other ancestors, by generation 1 generation back: 3 other ancestors2 generations back: 1 other ancestor K960748 · Modified Hand Instrument Devices · United States Surgical, A Division of Tyco Healthc · 1996K944129 · Imagyn Laparoscopic Instruments · Imagyn Medical, Inc. · 19940
  1. Root · 2 generations backK944129 Imagyn Laparoscopic InstrumentsImagyn Medical, Inc. · 1994
  2. 1 generation backK960748 Modified Hand Instrument DevicesUnited States Surgical, A Division of Tyco Healthc · 1996
  3. This deviceK101101 Mini-TongMini Lap Technologies, Inc. · 2010
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K944129Imagyn Laparoscopic InstrumentsImagyn Medical, Inc.1994—
−1K960748Modified Hand Instrument DevicesUnited States Surgical, A Division of Tyco Healthc1996—
0 (this device)K101101Mini-TongMini Lap Technologies, Inc.2010—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199020
199910
200710
FIG. 1 — Lineage of K101101, 1994–2010Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in OCW? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new OCW device

  1. #1 K252400 Endomina EZFuse systemscore 12.0 · 5 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (4)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K070686Mini Lap Instruments
Summary page 5
…Endoscope Accessories o - KOA, 21 CFR 876.4730 Manual Surgical Instruments o FBQ, 21 CFR 878.5090 Trocar Predicate Device {21 CFR 807.92(a)(3)] o Mini Lap Instruments — K070686 - o U.S. Surgical — Modified Hand Instrument Devices — K960748 o Solos Endoscopy — 10mm Atraumatic Grasping Forcep and Smm Grasp…
Mini Lap Technologies, Inc.2007—
*K960748Modified Hand Instrument Devices
Summary page 5
…Instruments o FBQ, 21 CFR 878.5090 Trocar Predicate Device {21 CFR 807.92(a)(3)] o Mini Lap Instruments — K070686 - o U.S. Surgical — Modified Hand Instrument Devices — K960748 o Solos Endoscopy — 10mm Atraumatic Grasping Forcep and Smm Grasping Forcep — K900948 / K900958 Description of the Device {21 C…
United States Surgical, A Division of Tyco Healthc1996—
*K900948GS-1002 Grasping Forcep, 5MM with Ratchet
Summary page 5
…i Lap Instruments — K070686 - o U.S. Surgical — Modified Hand Instrument Devices — K960748 o Solos Endoscopy — 10mm Atraumatic Grasping Forcep and Smm Grasping Forcep — K900948 / K900958 Description of the Device {21 CFR 807.92(a)(4)] The MINI-TONG instruments are minimally invasive devices. Prior to in…
Solos Endoscopy, Inc.1990—
*K900958GS-1300 Atraumatic Grasping Forcep, Curved, 10MM
Summary page 5
…ruments — K070686 - o U.S. Surgical — Modified Hand Instrument Devices — K960748 o Solos Endoscopy — 10mm Atraumatic Grasping Forcep and Smm Grasping Forcep — K900948 / K900958 Description of the Device {21 CFR 807.92(a)(4)] The MINI-TONG instruments are minimally invasive devices. Prior to insertion, t…
Solos Endoscopy, Inc.1990—

Also cleared against K070686: 5 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 16 years and passes through 3 companies; a new generation was cleared every 14.3 years on median.
  • None of the 6 ancestors has a recall.
  • 5 other devices also cite its predicate K070686.

How does its category compare?

All OCW devices

OCW Endoscopic Tissue Approximation Device: FDA decisions, review times, recalls and adverse event reports over 20 years. 2010, this device’s year, is highlighted.

FDA decisions per year · OCW

1in 2025

2007: 52008: 42009: 32010: 42011: 12012: 12013: 22016: 22017: 22018: 22019: 12020: 12021: 32023: 32025: 12026 (partial year): 2
2007high 5 (2007) · low 0 (2014)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · OCW

133in 2023

2007: 58 days median2008: 70 days median2009: 30 days median2010: 91 days median2021: 221 days median2023: 133 days median
2007high 221 (2021) · low 30 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · OCW

3so far in 2026, the most since 2007

2023: 12026 (partial year): 3
2007high 3 (2026) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · OCW

326in 2025

2007: 92008: 472009: 302010: 102011: 162012: 282013: 22014: 282015: 592016: 742017: 4202018: 4132019: 2912020: 1832021: 1982022: 2352023: 2272024: 2112025: 326
2007high 420 (2017) · low 2 (2013)2025

MAUDE reports naming product code OCW, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200755809
2008470047
2009330030
2010491010
20111—016
20121—028
20132—02
20140—028
20150—059
20162—074
20172—0420
20182—0413
20191—0291
20201—0183
202132210198
20220—0235
202331331227
20240—0211
20251—0326
20262—3—

What is it indicated for?

The devices are used for temporary grasping and clamping of soft tissue and small tubular structures during minimally invasive procedures.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K101101: Mini-Tong.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K101101

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026