510(k) · Cleared
ClearedMedtronic Contour 3D Annuloplasty Ring, Model 690R
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Medtronic, Inc. · KRH Ring, Annuloplasty
Cleared on Aug 7, 2010 as substantially equivalent to K020864 (Edwards Lifesciences, LLC, 2002) after a 99-day review. Its family tree reaches back 2 generations to 1993.
- Decided
- Aug 7, 2010
- Review
- 99 days
- Class
- Class II
- Product code
- KRH
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 2 generations to K923367 (1993). No later device cites it as a predicate yet.
- Root · 2 generations backK923367 Cosgrove Edwards Annuloplasty System, Model 4600Baxter Healthcare Corp · 1993
- 1 generation backK020864 Edwards MC Tricuspid Annuloplasty System, Model 4900Edwards Lifesciences, LLC · 2002
- This deviceK101212 Medtronic Contour 3D Annuloplasty Ring, Model 690RMedtronic, Inc. · 2010
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −2 | K923367 | Cosgrove Edwards Annuloplasty System, Model 4600 | Baxter Healthcare Corp | 1993 | — |
| −1 | K020864 | Edwards MC Tricuspid Annuloplasty System, Model 4900 | Edwards Lifesciences, LLC | 2002 | — |
| 0 (this device) | K101212 | Medtronic Contour 3D Annuloplasty Ring, Model 690R | Medtronic, Inc. | 2010 | — |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in KRH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new KRH device
- #1 K261707 MEMO 4D Curve™ Semirigid mitral annuloplasty…score 12.7 · 5 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K020864 | Edwards MC Tricuspid Annuloplasty System, Model 4900Summary page 1…74) KRH III. IDENTIFICATION OF PREDICATE DEVICE Trade/Proprietary Name: MG3 Tricuspid Annuloplasty System 510(k) Number: K020864 5 10(k) Clearance Date: April 17, 2002 IV. DEVICE DESCRIPTION The Contour 3DTM Annuloplasty… | 2002 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 17 years and passes through 3 companies; a new generation was cleared every 9.3 years on median.
- None of the 2 ancestors has a recall.
- 3 other devices also cite its predicate K020864.
How does its category compare?
All KRH devicesKRH Ring, Annuloplasty: FDA decisions, review times, recalls and adverse event reports over 20 years. 2010, this device’s year, is highlighted.
FDA decisions per year · KRH
4in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · KRH
98in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · KRH
No recall names KRH since 2007.
Adverse event reports per year · KRH
420in 2025
MAUDE reports naming product code KRH, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 4 | 90 | 0 | 261 |
| 2008 | 2 | — | 0 | 1,288 |
| 2009 | 8 | 68 | 0 | 973 |
| 2010 | 2 | — | 0 | 630 |
| 2011 | 2 | — | 0 | 321 |
| 2012 | 0 | — | 0 | 90 |
| 2013 | 0 | — | 0 | 97 |
| 2014 | 1 | — | 0 | 73 |
| 2015 | 0 | — | 0 | 145 |
| 2016 | 1 | — | 0 | 347 |
| 2017 | 0 | — | 0 | 379 |
| 2018 | 2 | — | 0 | 378 |
| 2019 | 2 | — | 0 | 349 |
| 2020 | 2 | — | 0 | 340 |
| 2021 | 0 | — | 0 | 423 |
| 2022 | 0 | — | 0 | 372 |
| 2023 | 2 | — | 0 | 324 |
| 2024 | 1 | — | 0 | 407 |
| 2025 | 4 | 98 | 0 | 420 |
| 2026 | 2 | — | 0 | — |
What is it indicated for?
The Contour 3D Ring is indicated for the reconstruction and/or remodeling of pathological tricuspid valves.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K101212 · printed Nov 6, 2026
Cite this page
510(k) Report. “K101212: Medtronic Contour 3D Annuloplasty Ring, Model 690R.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K101212
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026