510(k) Report

510(k) · Cleared

Cleared

Apex Module Hip System Biolox Delta Femoral Head

K101451510(k) SpecialCleared Jun 22, 201028-day reviewClass II21 CFR 888.3353

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Omni Life Science, Inc. · LZO Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented

Cleared on Jun 22, 2010 as substantially equivalent to K012918 (Apex Surgical, LLC, 2001) and 2 other predicates after a 28-day review. Its family tree reaches back 7 generations to 1993. 4 later devices descend from it.

Decided
Jun 22, 2010
Review
28 days
Class
Class II
Product code
LZO
Recalls
None
Predicates
3

Its longest line of descent runs back 7 generations to K930712 (1993). 50 ancestors in all, the oldest K823727 (1983). 4 later devices descend from it, 2 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2001: 2 other ancestors2007: 1 other ancestor2006: 1 other ancestor2004: 1 other ancestor2000: 4 other ancestors1999: 1 other ancestor1998: 2 other ancestors2005: 1 other ancestor1997: 4 other ancestors1996: 3 other ancestors1994: 6 other ancestors1991: 2 other ancestors1995: 3 other ancestors1992: 1 other ancestor1993: 2 other ancestors1990: 1 other ancestor1988: 1 other ancestor1987: 2 other ancestors1986: 3 other ancestors1983: 2 other ancestors2021: 1 descendant cleared2017: 1 descendant cleared2024: 1 descendant cleared2026: 1 descendant clearedK930712 · P.F.C. Total Hip System Porous Coated Modular · Johnson & Johnson Orthopaedics, Inc. · 1993K983014 · Summit Acetabular System · Johnson & Johnson Professionals, Inc. · 1998×2: 2 generations cleared close together, K000306 (2000), K001534 (2000) K031110 · Apex Modular Acetabular Cup · Apex Surgical, LLC · 2003K073150 · Apex-LNK Poly Acetabular Cup Liners · Omni Life Science, Inc. · 2008K100555 · Apex-LNK Acetabular Insert, E, Apex-LNK Acetabular Insert, F, Apex-LNK · Omni Life Science, Inc. · 2010 · recalled19801990200020102020
  1. Root · 7 generations backK930712 P.F.C. Total Hip System Porous Coated ModularJohnson & Johnson Orthopaedics, Inc. · 1993
  2. 6 generations backK983014 Summit Acetabular SystemJohnson & Johnson Professionals, Inc. · 1998
  3. 5 generations backK000306 Pinnacle Acetabular SystemDePuy Orthopaedics, Inc. · 2000 · Recalled
  4. 4 generations backK001534 Pinnacle Acetabular SystemDePuy Orthopaedics, Inc. · 2000
  5. 3 generations backK031110 Apex Modular Acetabular CupApex Surgical, LLC · 2003
  6. 2 generations backK073150 Apex-LNK Poly Acetabular Cup LinersOmni Life Science, Inc. · 2008
  7. 1 generation backK100555 Apex-LNK Acetabular Insert, E, Apex-LNK Acetabular Insert, F, Apex-LNKOmni Life Science, Inc. · 2010 · Recalled
  8. This deviceK101451 Apex Module Hip System Biolox Delta Femoral HeadOmni Life Science, Inc. · 2010
  9. Descendant · cites it directly · 2 of its ownK201657 Corin Ltd. Hip Products: Trinity™ Acetabular System, Trinity™ PLUS…Corin, Ltd. · 2021
  10. Descendant · 2 generations on · 1 of its ownK241472 Icona Hip StemCorin U.S.A. Limited · 2024
  11. Descendant · 3 generations on · 0 of its ownK261576 Icona Hip StemCorin, Ltd. · 2026
  12. Descendant · cites it directly · 0 of its ownK171156 OMNI Anseris Hip StemOmnilife Science · 2017

Most influential descendants

Showing 4 of 4 · See all
  • K201657Corin Ltd. Hip Products: Trinity™ Acetabular System, Trinity™ PLUS Acetabular Shell…Corin, Ltd. · 2021 · cites it directly2descendants
  • K241472Icona Hip StemCorin U.S.A. Limited · 2024 · 2 generations on1descendant
  • K261576Icona Hip StemCorin, Ltd. · 2026 · 3 generations on0descendants
  • K171156OMNI Anseris Hip StemOmnilife Science · 2017 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−7K930712P.F.C. Total Hip System Porous Coated ModularJohnson & Johnson Orthopaedics, Inc.1993—
−6K983014Summit Acetabular SystemJohnson & Johnson Professionals, Inc.1998—
−5K000306Pinnacle Acetabular SystemDePuy Orthopaedics, Inc.20001
−4K001534Pinnacle Acetabular SystemDePuy Orthopaedics, Inc.2000—
−3K031110Apex Modular Acetabular CupApex Surgical, LLC2003—
−2K073150Apex-LNK Poly Acetabular Cup LinersOmni Life Science, Inc.2008—
−1K100555Apex-LNK Acetabular Insert, E, Apex-LNK Acetabular Insert, F, Apex-LNKOmni Life Science, Inc.20101
0 (this device)K101451Apex Module Hip System Biolox Delta Femoral HeadOmni Life Science, Inc.2010—
+1K201657Corin Ltd. Hip Products: Trinity™ Acetabular System, Trinity™ PLUS Acetabular…Corin, Ltd.2021—
+2K241472Icona Hip StemCorin U.S.A. Limited2024—
+3K261576Icona Hip StemCorin, Ltd.2026—
+1K171156OMNI Anseris Hip StemOmnilife Science2017—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198320
198630
198720
198810
199010
199120
199210
199320
199460
199530
199630
199740
199820
199910
200040
200120
200410
200510
200610
200710

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201710
202110
202410
202610
FIG. 1 — Lineage of K101451, 1993–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LZO? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LZO device

  1. #1 K192827 Quadra-Pscore 19.3 · 10 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K012918Apex Modular Alumina Femoral Head
Summary page 2
…deice) (subjct (K012918, K 073150) (K(100555)…
Apex Surgical, LLC2001—
*K073150Apex-LNK Poly Acetabular Cup Liners
Summary page 2
…deice) (subjct (K012918, K 073150) (K(100555)…
Omni Life Science, Inc.2008—
*K100555Apex-LNK Acetabular Insert, E, Apex-LNK Acetabular Insert, F, Apex-LNK
Summary page 1
…1S0- ApeX-LNK Poly Acetabular Cup Liners- 36mm Alumina Femoral Heads, February 27, 2008 * 1(100555- ApeX-LNFK Poly Acetabular Liners and Apex Modular Head, March 29, 2010 Device Description The Apex Modular Hip…
Omni Life Science, Inc.20101

Also cleared against K012918: 2 other devices →

What descends from it? (4)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K201657Corin Ltd. Hip Products: Trinity™ Acetabular System, Trinity™ PLUS Acetabular Shell…Corin, Ltd.20212
K171156OMNI Anseris Hip StemOmnilife Science20170

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 17 years and passes through 5 companies; a new generation was cleared every 2.1 years on median.
  • 2 of the 50 ancestors have a recall of any class.
  • Of its descendants, K201657 (Corin, Ltd., 2021) has gone furthest, with 2 descendants of its own.
  • 2 other devices also cite its predicate K012918.

How does its category compare?

All LZO devices

LZO Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented: FDA decisions, review times, recalls and adverse event reports over 20 years. 2010, this device’s year, is highlighted.

FDA decisions per year · LZO

14in 2025

2007: 92008: 112009: 72010: 152011: 132012: 142013: 262014: 132015: 122016: 102017: 162018: 182019: 282020: 182021: 122022: 112023: 102024: 112025: 142026 (partial year): 9
2007high 28 (2019) · low 7 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LZO

119in 2025

2007: 87 days median2008: 63 days median2009: 83 days median2010: 78 days median2011: 87 days median2012: 98 days median2013: 100 days median2014: 85 days median2015: 115 days median2016: 177 days median2017: 257 days median2018: 163 days median2019: 109 days median2020: 112 days median2021: 170 days median2022: 279 days median2023: 122 days median2024: 111 days median2025: 119 days median2026 (partial year): 102 days median
2007high 279 (2022) · low 63 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LZO

1in 2025

2007: 22008: 132009: 422011: 102012: 142014: 12015: 12016: 92017: 52018: 22019: 42020: 32022: 42023: 22024: 12025: 1
2007high 42 (2009) · low 0 (2010)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LZO

3,244in 2025

2007: 1382008: 1252009: 1892010: 3942011: 5442012: 9632013: 1,3702014: 1,4772015: 1,3482016: 1,7282017: 2,1652018: 3,1332019: 3,0662020: 1,9632021: 2,1992022: 1,9852023: 2,0662024: 2,5862025: 3,244
2007high 3,244 (2025) · low 125 (2008)2025

MAUDE reports naming product code LZO, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20079872138
2008116313125
200978342189
201015780394
2011138710544
2012149814963
20132610001,370
2014138511,477
20151211511,348
20161017791,728
20171625752,165
20181816323,133
20192810943,066
20201811231,963
20211217002,199
20221127941,985
20231012222,066
20241111112,586
20251411913,244
202691020—

What is it indicated for?

The Apex Modular™ Ceramic Femoral Heads are intended for use in combination with the Apex Modular Hip Stem as the femoral component in total hip replacement procedures. This ceramic head is intended to articulate with a polyethylene or metal-backed polyethylene acetabular cup or bipolar component. This prosthesis is intended for single use implantation, and may be used for the following conditions, as appropriate: * Non-inflammatory degenerative joint…

Read the full statement (104 words)

The Apex Modular™ Ceramic Femoral Heads are intended for use in combination with the Apex Modular Hip Stem as the femoral component in total hip replacement procedures. This ceramic head is intended to articulate with a polyethylene or metal-backed polyethylene acetabular cup or bipolar component. This prosthesis is intended for single use implantation, and may be used for the following conditions, as appropriate:

* Non-inflammatory degenerative joint disease, including osteoiarthritis and avascular necrosis;

* Rheumatoid arthritis;

* Correction of functional deformity;

* Congenital dislocation;

* Revision procedures where other treatments or devices have failed

* Femoral neck and trochanteric fractures of the proximal femur.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K101451: Apex Module Hip System Biolox Delta Femoral Head.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K101451

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026