510(k) Report

510(k) · Cleared

Cleared

Multifit Total Hip System

K101472510(k) AbbreviatedCleared Jan 5, 2011223-day reviewClass II21 CFR 888.3353

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Otis Biotech Co., Ltd. · LZO Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented

Cleared on Jan 5, 2011 as substantially equivalent to K011489 (DePuy Orthopaedics, Inc., 2001) and 9 other predicates after a 223-day review. Its family tree reaches back 6 generations to 1994.

Decided
Jan 5, 2011
Review
223 days
Class
Class II
Product code
LZO
Recalls
None
Predicates
10

Its longest line of descent runs back 6 generations to K935452 (1994). 37 ancestors in all, the oldest K812672 (1981). No later device cites it as a predicate yet.

Other ancestors, by year cleared 2005: 1 other ancestor2002: 1 other ancestor2000: 2 other ancestors1999: 2 other ancestors1998: 3 other ancestors1997: 3 other ancestors1994: 5 other ancestors1991: 2 other ancestors1981: 1 other ancestor1983: 1 other ancestor1996: 3 other ancestors1995: 1 other ancestor1984: 1 other ancestor1993: 1 other ancestor1985: 1 other ancestor1992: 2 other ancestorsK935452 · P.F.C. 2 Total Hip System Porous Coated Modular Femoral Component · Johnson & Johnson Orthopaedics, Inc. · 1994K945518 · P.F.C. 2 Total Hip System Porous Coated Modular Femoral Component · Johnson & Johnson Professionals, Inc. · 1996K961939 · S-Rom Femoral Hip Stem (Sizes 12 X 06 X 115 and 12 X 07 X 115) · Johnson & Johnson Professionals, Inc. · 1996K974331 · Uni-Rom Total Hip System Femoral Stem · Johnson & Johnson Professionals, Inc. · 1998K001991 · Titan Porocoat Hip Prosthesis · DePuy Orthopaedics, Inc. · 2000K011489 · Summit Duofix Hip Prosthesis · DePuy Orthopaedics, Inc. · 20011980198519901995200020052010
  1. Root · 6 generations backK935452 P.F.C. 2 Total Hip System Porous Coated Modular Femoral ComponentJohnson & Johnson Orthopaedics, Inc. · 1994
  2. 5 generations backK945518 P.F.C. 2 Total Hip System Porous Coated Modular Femoral ComponentJohnson & Johnson Professionals, Inc. · 1996
  3. 4 generations backK961939 S-Rom Femoral Hip Stem (Sizes 12 X 06 X 115 and 12 X 07 X 115)Johnson & Johnson Professionals, Inc. · 1996
  4. 3 generations backK974331 Uni-Rom Total Hip System Femoral StemJohnson & Johnson Professionals, Inc. · 1998
  5. 2 generations backK001991 Titan Porocoat Hip ProsthesisDePuy Orthopaedics, Inc. · 2000
  6. 1 generation backK011489 Summit Duofix Hip ProsthesisDePuy Orthopaedics, Inc. · 2001
  7. This deviceK101472 Multifit Total Hip SystemOtis Biotech Co., Ltd. · 2011
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−6K935452P.F.C. 2 Total Hip System Porous Coated Modular Femoral ComponentJohnson & Johnson Orthopaedics, Inc.1994—
−5K945518P.F.C. 2 Total Hip System Porous Coated Modular Femoral ComponentJohnson & Johnson Professionals, Inc.1996—
−4K961939S-Rom Femoral Hip Stem (Sizes 12 X 06 X 115 and 12 X 07 X 115)Johnson & Johnson Professionals, Inc.1996—
−3K974331Uni-Rom Total Hip System Femoral StemJohnson & Johnson Professionals, Inc.1998—
−2K001991Titan Porocoat Hip ProsthesisDePuy Orthopaedics, Inc.2000—
−1K011489Summit Duofix Hip ProsthesisDePuy Orthopaedics, Inc.2001—
0 (this device)K101472Multifit Total Hip SystemOtis Biotech Co., Ltd.2011—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198110
198310
198410
198510
199120
199220
199310
199450
199510
199630
199730
199830
199920
200020
200210
200510
FIG. 1 — Lineage of K101472, 1994–2011Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LZO? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LZO device

  1. #1 K192827 Quadra-Pscore 19.3 · 10 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (10)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K011489Summit Duofix Hip Prosthesis
Summary page 2
…Code Number Cementless Tapered Stem i )Depuy Orthopaedicss, Inc. K01 1489 LPH SummitT~M DuoFixim Hip Prosthesis ii Osteonic…
DePuy Orthopaedics, Inc.2001—
*K982032Osteonics Omnifit HA Hip Stem Series, Osteonics Secur-Fit HA Hip Stem Series, Osteonics…
Summary page 2
…01 1489 LPH SummitT~M DuoFixim Hip Prosthesis ii Osteonics corporation. K982032 MEH Osteonics Imnifit HA Hip stem series Cement Collared Stem i )Wr…
Osteonics Corp.19981
*K972641Dual Offset Perfecta Imc Hip Stem
Summary page 2
…2032 MEH Osteonics Imnifit HA Hip stem series Cement Collared Stem i )Wright Medical Technology INC. K972641 JDI PERFECTAO IMC Hip System ii) Smith & Nephew,…
Wrightmedicaltechnologyinc1997—
*K990369Synergy Cemented Hip Stem
Summary page 2
…K972641 JDI PERFECTAO IMC Hip System ii) Smith & Nephew, Inc. K990369 LPH Synergy Cemented Hip stem Acetabular System i )Zimmer, Inc.…
Smith & Nephew, Inc.1999—
*K934765Trilogy Acetabular System
Summary page 2
…K990369 LPH Synergy Cemented Hip stem Acetabular System i )Zimmer, Inc. K934765 LPH Trilogy Acetahular System i i Smith & Nephew,…
Zimmer, Inc.199416
*K002747Reflection Cross-Linked Uhmwpe Acetabular Components
Summary page 2
…K934765 LPH Trilogy Acetahular System i i Smith & Nephew, Inc. K002747 LPH, Reflection Cross-lintked UHMWPE D…
Smith & Nephew, Inc.2000—
*K812672Self-Centering Hip
Summary page 2
…HMWPE D acetabular component Bipolar System i )Depuy, Inc. K812672 KWY Self-centering Hip prosthesis ii) Biomet, Inc…
Depuy, Inc.1981—
*K051569Ringloc BI-Polar Acetabular Component
Summary page 2
…K812672 KWY Self-centering Hip prosthesis ii) Biomet, Inc. K051569 JED Ringloc Si-polar acetabular component…
Biomet, Inc.20054
*K021673Total Hip Femoral Head - 12/14 Taper
Summary page 2
…Ringloc Si-polar acetabular component Femoral Ball Head i ) Smith & Nephew, Inc. K02 1673 LZO Total Hip Femoral Head - 12/14 Taper…
Smith & Nephew, Inc.20021
*K911684Biomet Cobalt-Chrome Femoral Components
Summary page 2
…Total Hip Femoral Head - 12/14 Taper ii) Biomet, Inc. K91 1684 JDI Biomet Cobalt-chrome femoral components…
Biomet, Inc.199112

Also cleared against K011489: 4 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 17 years and passes through 4 companies; a new generation was cleared every 1.5 years on median.
  • 8 of the 36 ancestors have a recall of any class.
  • 4 other devices also cite its predicate K011489.

How does its category compare?

All LZO devices

LZO Prosthesis, Hip, Semi-Constrained, Metal/Ceramic/Polymer, Cemented Or Non-Porous, Uncemented: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.

FDA decisions per year · LZO

14in 2025

2007: 92008: 112009: 72010: 152011: 132012: 142013: 262014: 132015: 122016: 102017: 162018: 182019: 282020: 182021: 122022: 112023: 102024: 112025: 142026 (partial year): 9
2007high 28 (2019) · low 7 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LZO

119in 2025

2007: 87 days median2008: 63 days median2009: 83 days median2010: 78 days median2011: 87 days median2012: 98 days median2013: 100 days median2014: 85 days median2015: 115 days median2016: 177 days median2017: 257 days median2018: 163 days median2019: 109 days median2020: 112 days median2021: 170 days median2022: 279 days median2023: 122 days median2024: 111 days median2025: 119 days median2026 (partial year): 102 days median
2007high 279 (2022) · low 63 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LZO

1in 2025

2007: 22008: 132009: 422011: 102012: 142014: 12015: 12016: 92017: 52018: 22019: 42020: 32022: 42023: 22024: 12025: 1
2007high 42 (2009) · low 0 (2010)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LZO

3,244in 2025

2007: 1382008: 1252009: 1892010: 3942011: 5442012: 9632013: 1,3702014: 1,4772015: 1,3482016: 1,7282017: 2,1652018: 3,1332019: 3,0662020: 1,9632021: 2,1992022: 1,9852023: 2,0662024: 2,5862025: 3,244
2007high 3,244 (2025) · low 125 (2008)2025

MAUDE reports naming product code LZO, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20079872138
2008116313125
200978342189
201015780394
2011138710544
2012149814963
20132610001,370
2014138511,477
20151211511,348
20161017791,728
20171625752,165
20181816323,133
20192810943,066
20201811231,963
20211217002,199
20221127941,985
20231012222,066
20241111112,586
20251411913,244
202691020—

What is it indicated for?

The hip system is intended to be cemented stem or un cemented stem use.

The MultiFit Total Hip System is to replace a defective hip joint in the following cases:

1) Patients suffering from severe hip pain and disability due to rheumatoid arthritis, osteoarthritis, traumatic arthritis, polyarthritis, collagen disorders, avascular necrosis of the femoral head and nonunion of previous fractures of the femur;

2) Patients with congenital hip dysplasia, protrusion acetabuli, or slipped capital femoral epiphysis;

3) Patients suffering from disability due to previous fusion and previously failed endo-prostheses;

4) Patients with acute femoral neck fractures.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K101472: Multifit Total Hip System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K101472

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026