510(k) Report

510(k) · Cleared

Cleared

Resusci Flow; Resusci Flow 104

K102542510(k) TraditionalCleared Apr 6, 2011215-day reviewClass II21 CFR 868.5925

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Atom Medical Corporation · BTL Ventilator, Emergency, Powered (Resuscitator)

Cleared on Apr 6, 2011 as substantially equivalent to K892885 (Fisher & Paykel Electronics, Ltd., 1989) and 1 other predicate after a 215-day review. Its family tree reaches back 3 generations to 1976. 1 of the 9 devices in its family, counting itself, has a Class I recall.

Decided
Apr 6, 2011
Review
215 days
Class
Class II
Product code
BTL
Recalls
None
Predicates
2

Its longest line of descent runs back 3 generations to K760102 (1976). 8 ancestors in all. No later device cites it as a predicate yet. 1 of the 9 devices in this family, counting this one, has a Class I recall.

Other ancestors, by year cleared 1989: 1 other ancestor2000: 2 other ancestors1988: 1 other ancestor1985: 1 other ancestorK760102 · Flowmeter, P.C., Redesigned Version · Ohio Medical Products · 1976K971243 · Ohmeda Infant Resuscitation System · Ohmeda Medical · 1997K070210 · Giraffe and Panda T- Piece Resuscitation System · Ohmeda Medical · 2007 · Class I recall1980199020002010
Other ancestors, by generation 1 generation back: 1 other ancestor2 generations back: 2 other ancestors3 generations back: 2 other ancestors K070210 · Giraffe and Panda T- Piece Resuscitation System · Ohmeda Medical · 2007 · Class I recallK971243 · Ohmeda Infant Resuscitation System · Ohmeda Medical · 1997K760102 · Flowmeter, P.C., Redesigned Version · Ohio Medical Products · 19760
  1. Root · 3 generations backK760102 Flowmeter, P.C., Redesigned VersionOhio Medical Products · 1976
  2. 2 generations backK971243 Ohmeda Infant Resuscitation SystemOhmeda Medical · 1997
  3. 1 generation backK070210 Giraffe and Panda T- Piece Resuscitation SystemOhmeda Medical · 2007 · Recalled (Class I)
  4. This deviceK102542 Resusci Flow; Resusci Flow 104Atom Medical Corporation · 2011

Class I recalls in this family

View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K760102Flowmeter, P.C., Redesigned VersionOhio Medical Products1976—
−2K971243Ohmeda Infant Resuscitation SystemOhmeda Medical1997—
−1K070210Giraffe and Panda T- Piece Resuscitation SystemOhmeda Medical2007Class I
0 (this device)K102542Resusci Flow; Resusci Flow 104Atom Medical Corporation2011—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198510
198810
198910
200020
FIG. 1 — Lineage of K102542, 1976–2011Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new BTL device

  1. #1 K242769 VentStar Resus heated (N) (MP17030); VentStar…score 11.2 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K892885Resubmitted RD1000 Neopuff Infant Resuscitator
Summary page 1
…Resusci Flow 104 PV Predicate Devices: GE - Giraffe and Panda - K0702 10 Fisher & Paykel - NeoPuff - K892885 Device Description: There are four (4) models of the Resusci Flow resuscitator. * Resusci Flow * Resusci Flow with blender…
Fisher & Paykel Electronics, Ltd.1989—
*K070210Giraffe and Panda T- Piece Resuscitation System
Summary page 1
…w and blender Resusci Flow 104 EV Resusci Flow 104 PV Predicate Devices: GE - Giraffe and Panda - K0702 10 Fisher & Paykel - NeoPuff - K892885 Device Description: There are four (4) models of the Resusci F…
Ohmeda Medical2007Class I

Also cleared against K892885: 11 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (1 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K070210Giraffe and Panda T- Piece Resuscitation SystemOhmeda Medical · 2007 · Direct predicate · ◆ on the line of descent in FIG. 13 Class I recalls

What does this lineage say?

  • The line of descent spans 35 years and passes through 3 companies; a new generation was cleared every 9.4 years on median.
  • 2 of the 8 ancestors have a recall of any class; 1 has a Class I recall.
  • 11 other devices also cite its predicate K892885.

How does its category compare?

All BTL devices

BTL Ventilator, Emergency, Powered (Resuscitator): FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.

FDA decisions per year · BTL

1in 2025

2007: 52008: 42009: 52010: 32011: 22013: 12014: 72015: 12017: 22018: 12019: 12020: 12021: 12023: 12025: 1
2007high 7 (2014) · low 0 (2012)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · BTL

203in 2014

2007: 122 days median2008: 198 days median2009: 173 days median2010: 140 days median2014: 203 days median
2007high 203 (2014) · low 122 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · BTL

2in 2024

2007: 12011: 12012: 2, 2 Class I2013: 3, 1 Class I2015: 3, 2 Class I2019: 3, 3 Class I2021: 12024: 2, 2 Class I
2007high 3 (2013) · low 0 (2008)2026

Class I (10 since 2007) Class II/III not classified

Adverse event reports per year · BTL

165in 2025

2007: 52008: 372009: 692010: 962011: 752012: 1152013: 1032014: 702015: 792016: 802017: 1012018: 1972019: 3412020: 4542021: 5062022: 7552023: 7312024: 6672025: 165
2007high 755 (2022) · low 5 (2007)2025

MAUDE reports naming product code BTL, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007512215
20084198037
20095173069
20103140096
20112—175
20120—2 (2)115
20131—3 (1)103
20147203070
20151—3 (2)79
20160—080
20172—0101
20181—0197
20191—3 (3)341
20201—0454
20211—1506
20220—0755
20231—0731
20240—2 (2)667
20251—0165
20260—0—

What is it indicated for?

The Resusci Flow series (Resusci Flow and Resusci Flow with blender) is a manually operated ventilator intended to assist a doctor in resuscitating an infant who has spontaneous breathing by providing the positive end-expiratory pressure (PEEP) and the peak inspiratory pressure (PIP).

The Resusci Flow series (Resusci Flow 104 PV and Resusci Flow 104EV) is intended for resuscitation of neonates in a delivery room and a NICU. It is used to remove secretions from the neonatal mouth and nostrils or to ventilate or assist in ventilating neonates suffering from apnea or other respiratory failure.

All are intended for neonates and infants (< 10kg or 22 Ibs) in a delivery room and a NICU.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K102542: Resusci Flow; Resusci Flow 104.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K102542

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026