510(k) Report

510(k) · Cleared

Cleared

Oxymag - Transport and Emergency Ventilator

K221634510(k) TraditionalCleared May 24, 2023352-day reviewClass II21 CFR 868.5925

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Magnamed Tecnologia Medica S/A · BTL Ventilator, Emergency, Powered (Resuscitator)

Cleared on May 24, 2023 as substantially equivalent to K141595 (O-Two Medical Technologies, Inc., 2015) after a 352-day review. Its family tree reaches back 7 generations to 1997. 2 of the 25 devices in its family, counting itself, have a Class I recall.

Decided
May 24, 2023
Review
352 days
Class
Class II
Product code
BTL
Recalls
None
Predicates
1

Its longest line of descent runs back 7 generations to K962603 (1997). 24 ancestors in all, the oldest K860555 (1986). No later device cites it as a predicate yet. 2 of the 25 devices in this family, counting this one, have a Class I recall.

  1. Root · 7 generations backK962603 Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & CablesMasimo Corp. · 1997
  2. 6 generations backK973887 Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and…Masimo Corp. · 1998
  3. 5 generations backK990966 Masimo Set 2000 Pulse Oximeter, Masimo Lnop -Adt-Adult/Pediatric…Masimo Corp. · 1999
  4. 4 generations backK021981 Ivent 201 Portable VentilatorVersamed, Ltd. · 2003
  5. 3 generations backK042468 Ivent 201 Portable VentilatorVersamed Medical Systems, Inc. · 2004
  6. 2 generations backK062267 Oxylog 3000Drager Medical B.V. · 2006 · Recalled (Class I)
  7. 1 generation backK141595 O-Two E700,O-Two E600,O-Two E500O-Two Medical Technologies, Inc. · 2015 · Recalled (Class I)
  8. This deviceK221634 Oxymag - Transport and Emergency VentilatorMagnamed Tecnologia Medica S/A · 2023

Class I recalls in this family

View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−7K962603Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & CablesMasimo Corp.1997—
−6K973887Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and CablesMasimo Corp.1998—
−5K990966Masimo Set 2000 Pulse Oximeter, Masimo Lnop -Adt-Adult/Pediatric Disposable…Masimo Corp.1999—
−4K021981Ivent 201 Portable VentilatorVersamed, Ltd.2003—
−3K042468Ivent 201 Portable VentilatorVersamed Medical Systems, Inc.2004—
−2K062267Oxylog 3000Drager Medical B.V.2006Class I
−1K141595O-Two E700,O-Two E600,O-Two E500O-Two Medical Technologies, Inc.2015Class I
0 (this device)K221634Oxymag - Transport and Emergency VentilatorMagnamed Tecnologia Medica S/A2023—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198610
199310
199520
199610
199840
199930
200010
200120
200410
200910
FIG. 1 — Lineage of K221634, 1997–2023Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

2 devices in this family have a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new BTL device

  1. #1 K242769 VentStar Resus heated (N) (MP17030); VentStar…score 11.2 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K141595O-Two E700,O-Two E600,O-Two E500
Summary page 4
…assification Name: Powered Emergency Ventilator (21 CFR 868.5925) Regulatory Class: Class II Product code: BTL III. PREDICATE DEVICE O-two e700, K141595 Manufactured by O-Two Medical Technologies Inc This predicate has not been subject to a design-related recall.…
O-Two Medical Technologies, Inc.2015Class I

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (2 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K141595O-Two E700,O-Two E600,O-Two E500O-Two Medical Technologies, Inc. · 2015 · Direct predicate · ◆ on the line of descent in FIG. 13 Class I recalls
  • K062267Oxylog 3000Drager Medical B.V. · 2006 · 2 generations back · ◆ on the line of descent in FIG. 13 Class I recalls

What does this lineage say?

  • The line of descent spans 26 years and passes through 6 companies; a new generation was cleared every 2.0 years on median.
  • 3 of the 24 ancestors have a recall of any class; 2 have a Class I recall.

How does its category compare?

All BTL devices

BTL Ventilator, Emergency, Powered (Resuscitator): FDA decisions, review times, recalls and adverse event reports over 20 years. 2023, this device’s year, is highlighted.

FDA decisions per year · BTL

1in 2025

2007: 52008: 42009: 52010: 32011: 22013: 12014: 72015: 12017: 22018: 12019: 12020: 12021: 12023: 12025: 1
2007high 7 (2014) · low 0 (2012)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · BTL

203in 2014

2007: 122 days median2008: 198 days median2009: 173 days median2010: 140 days median2014: 203 days median
2007high 203 (2014) · low 122 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · BTL

2in 2024

2007: 12011: 12012: 2, 2 Class I2013: 3, 1 Class I2015: 3, 2 Class I2019: 3, 3 Class I2021: 12024: 2, 2 Class I
2007high 3 (2013) · low 0 (2008)2026

Class I (10 since 2007) Class II/III not classified

Adverse event reports per year · BTL

165in 2025

2007: 52008: 372009: 692010: 962011: 752012: 1152013: 1032014: 702015: 792016: 802017: 1012018: 1972019: 3412020: 4542021: 5062022: 7552023: 7312024: 6672025: 165
2007high 755 (2022) · low 5 (2007)2025

MAUDE reports naming product code BTL, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007512215
20084198037
20095173069
20103140096
20112—175
20120—2 (2)115
20131—3 (1)103
20147203070
20151—3 (2)79
20160—080
20172—0101
20181—0197
20191—3 (3)341
20201—0454
20211—1506
20220—0755
20231—0731
20240—2 (2)667
20251—0165
20260—0—

What is it indicated for?

Oxymag is a controlled volume, pressure and time cycled emergency and transport ventilator. It is intended for use with infant, child, and adult patients with a tidal volume from 50 ml upwards who are in respiratory and/or cardiac arrest or respiratory distress and who require the ventilatory support.

It is intended for pre-hospital and hospital use including intra-hospital, inter-hospital and transport settings.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K221634: Oxymag - Transport and Emergency Ventilator.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K221634

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026