2.4MM VA-LCP Dorsal Distal Radius Plates

K102694510(k) TraditionalCleared Dec 9, 201080-day reviewClass II21 CFR 888.3030Recalls 3

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Synthes (Usa) · HRS Plate, Fixation, Bone

Cleared on Dec 9, 2010 as substantially equivalent to K012114 (Synthes (Usa), 2001) and 3 other predicates after an 80-day review. Its family tree reaches back 2 generations to 1996. 50 later devices descend from it. It has been recalled 3 times.

Decided
Dec 9, 2010
Review
80 days
Class
Class II
Product code
HRS
Recalls
3
Predicates
4

Its longest line of descent runs back 2 generations to K962616 (1996). 6 ancestors in all. 50 later devices descend from it, 13 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2007: 1 other ancestor2003: 1 other ancestor2001: 1 other ancestor1996: 1 other ancestor2014: 2 descendants cleared2024: 9 descendants cleared2018: 5 descendants cleared2011: 1 descendant cleared2016: 1 descendant cleared2019: 4 descendants cleared2017: 6 descendants cleared2013: 1 descendant cleared2022: 2 descendants cleared2026: 8 descendants cleared2020: 2 descendants cleared2025: 4 descendants cleared2021: 4 descendants cleared2023: 1 descendant clearedK962616 · Synthes Dorsal Distal Radius Plate (DDRP) System · Synthes (Usa) · 1996K982732 · Synthes (Usa) Distal Radius Plate System (DRPS) · Synthes · 19981995200020052010201520202025
Other ancestors, by generationDescendants, by generation 1 generation back: 3 other ancestors2 generations back: 1 other ancestor 1 generation forward: 13 descendants2 generations forward: 20 descendants3 generations forward: 11 descendants4 generations forward: 3 descendants5 generations forward: 2 descendants6 generations forward: 1 descendant K982732 · Synthes (Usa) Distal Radius Plate System (DRPS) · Synthes · 1998K962616 · Synthes Dorsal Distal Radius Plate (DDRP) System · Synthes (Usa) · 19960+5
  1. Root · 2 generations backK962616 Synthes Dorsal Distal Radius Plate (DDRP) SystemSynthes (Usa) · 1996
  2. 1 generation backK982732 Synthes (Usa) Distal Radius Plate System (DRPS)Synthes · 1998
  3. This deviceK102694 2.4MM VA-LCP Dorsal Distal Radius PlatesSynthes (Usa) · 2010
  4. Descendant · cites it directly · 14 of its ownK163361 ANTHEM™ Fracture SystemGlobus Medical, Inc. · 2017
  5. Descendant · 2 generations on · 11 of its ownK173166 ANTHEM Fracture SystemGlobus Medical, Inc. · 2017
  6. Descendant · 2 generations on · 10 of its ownK180554 ANTHEM Fracture SystemGlobus Medical, Inc. · 2018
  7. Descendant · 2 generations on · 8 of its ownK202496 ANTHEM Fracture SystemGlobus Medical, Inc. · 2020
  8. Descendant · cites it directly · 8 of its ownK142419 Mini and Micro Fragments Reconstruction System-NEOFIXNeoortho Productos Orthopedicos S/A · 2014

Showing 5 of 50 descendants. See all descendants

Descendants cleared per year

2011: 12013: 12014: 22016: 12017: 62018: 52019: 42020: 22021: 42022: 22023: 12024: 92025: 42026: 8
2011high 9 (2024) · low 0 (2012)2026

Most influential descendants

Showing 5 of 50 · See all
  • K163361ANTHEM™ Fracture SystemGlobus Medical, Inc. · 2017 · cites it directly14descendants
  • K173166ANTHEM Fracture SystemGlobus Medical, Inc. · 2017 · 2 generations on11descendants
  • K180554ANTHEM Fracture SystemGlobus Medical, Inc. · 2018 · 2 generations on10descendants
  • K202496ANTHEM Fracture SystemGlobus Medical, Inc. · 2020 · 2 generations on8descendants
  • K142419Mini and Micro Fragments Reconstruction System-NEOFIXNeoortho Productos Orthopedicos S/A · 2014 · cites it directly8descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K962616Synthes Dorsal Distal Radius Plate (DDRP) SystemSynthes (Usa)1996—
−1K982732Synthes (Usa) Distal Radius Plate System (DRPS)Synthes1998—
0 (this device)K1026942.4MM VA-LCP Dorsal Distal Radius PlatesSynthes (Usa)2010—
+1K163361ANTHEM™ Fracture SystemGlobus Medical, Inc.2017—
+2K173166ANTHEM Fracture SystemGlobus Medical, Inc.2017—
+2K180554ANTHEM Fracture SystemGlobus Medical, Inc.2018—
+2K202496ANTHEM Fracture SystemGlobus Medical, Inc.2020—
+1K142419Mini and Micro Fragments Reconstruction System-NEOFIXNeoortho Productos Orthopedicos S/A2014—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199610
200110
200310
200710

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201110
201310
201420
201610
201760
201850
201940
202020
202140
202220
202310
202490
202540
202680
FIG. 1 — Lineage of K102694, 1996–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in HRS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new HRS device

  1. #1 K222465 Tyber Medical Anatomical Plating Systemscore 27.5 · 16 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (4)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K012114Synthes Locking Distal Radius Plating System
Summary page 1
…Distal Radius System) into interstate commerce ahd to expand the indications of existing plate systems (K09 1644, K083694, K092556, K0121 14, K071 184 and K03 1725) to include "skeletally mature adolescenits and the following adolescent…
Synthes (Usa)20013
*K982732Synthes (Usa) Distal Radius Plate System (DRPS)
Summary page 1
…ener Predicate Device: Synthes Locking Distal Radius Plating System - (1(012114) Synthes Distal Radius Plate System - (K(982732) Synthes Small Titanium Wrist Fusion Plate - (1(023879) Synthes…
Synthes1998—
*K023879Small Titanium Wrist Fusion Plate
Summary page 1
…(012114) Synthes Distal Radius Plate System - (K(982732) Synthes Small Titanium Wrist Fusion Plate - (1(023879) Synthes Variable Angle Locking Compression Plate - (K(071184) Device Description:…
Synthes (Usa)2003—
*K071184Synthes (Usa) Variable Angle-Locking Compression Plate (VA-LCP) Distal Radius System
Summary page 1
…Radius System) into interstate commerce ahd to expand the indications of existing plate systems (K09 1644, K083694, K092556, K0121 14, K071 184 and K03 1725) to include "skeletally mature adolescenits and the following adolescent…
Synthes (Usa)20071

Also cleared against K012114: 15 other devices →

What descends from it? (50)

See all 50

13 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K163361ANTHEM™ Fracture SystemGlobus Medical, Inc.201714
K142419Mini and Micro Fragments Reconstruction System-NEOFIXNeoortho Productos Orthopedicos S/A20148
K163046DePuy Synthes 2.4/2.7mm VA LCP Two-Column Volar Distal Radius Plate, Extra-LongDePuy Synthes20175
K130774Universal Distal Radius SystemNewclip Technics20135
K1101252.4 MM VA-LCP Volar Rim Distal Radius SystemSynthes USA20115
K171320ARMAR / ARTIS Small Fragment and Calcaneal Plates & MBOSS / FIXION Screws, ARMAR/ ARTIS…Meril Healthcare Pvt., Ltd.20182
K170705ARIX Wrist SystemJeil Medical Corporation20172
K243308Bonebridge Osteosynthesis Plating System (SALGINA 2.5mm Distal Radius System, CASCELLA…Bonebridge AG20241
K190391TDM Plate and Screw SystemsTdm Co., Ltd.20191
K182650Arzzt Distal Radius and Ulna SystemTruemed Group, LLC20191

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jun 28, 2016Class IIZ-2389-2016Nonconforming Material/ComponentIt was reported that the specified lots of the 2.4mm Titanium Locking Screw Self-Tapping with Stardrive Recess 12mm can break between the head and the shaft. This resulted from the neck feature being too close to the StarDrive feature…
Nov 2, 2015Class IIZ-0323-2016Process controlIt was discovered that the above part number and lot of 2.4mm Locking Screws may contain the incorrect package insert (GP2613, VA-LCP Distal Radius System). The correct package insert for the above part is GP2615 (Modular Mini Fragment…
Jan 11, 2013Class IIZ-0956-2013Labeling mix-upsIt was discovered that one of the VA-LCP Dorsal Distal Radius Plates was incorrectly etched as Part Number 02.115.431 (110 degree) instead of the correct Part Number 02.115.231 (90 degree).

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 14 years and passes through 2 companies; a new generation was cleared every 12.2 years on median.
  • 2 of the 6 ancestors have a recall of any class.
  • Of its descendants, K163361 (Globus Medical, Inc., 2017) has gone furthest, with 14 descendants of its own.
  • 15 other devices also cite its predicate K012114.

How does its category compare?

All HRS devices

HRS Plate, Fixation, Bone: FDA decisions, review times, recalls and adverse event reports over 20 years. 2010, this device’s year, is highlighted.

FDA decisions per year · HRS

54in 2025

2007: 352008: 352009: 472010: 492011: 432012: 592013: 562014: 762015: 562016: 442017: 572018: 402019: 462020: 482021: 402022: 472023: 402024: 542025: 542026 (partial year): 51
2007high 76 (2014) · low 35 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HRS

90in 2025

2007: 63 days median2008: 87 days median2009: 85 days median2010: 100 days median2011: 88 days median2012: 106 days median2013: 89 days median2014: 57 days median2015: 97 days median2016: 109 days median2017: 122 days median2018: 116 days median2019: 89 days median2020: 88 days median2021: 87 days median2022: 144 days median2023: 120 days median2024: 96 days median2025: 90 days median2026 (partial year): 82 days median
2007high 144 (2022) · low 57 (2014)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · HRS

1in 2025

2007: 22008: 112009: 32010: 162011: 52012: 42013: 112015: 72016: 52017: 32018: 22019: 252020: 12021: 92022: 32023: 12025: 12026 (partial year): 3
2007high 25 (2019) · low 0 (2014)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · HRS

2,306in 2025

2007: 3392008: 3112009: 4352010: 4912011: 7732012: 1,6632013: 2,6432014: 2,4132015: 3,0952016: 2,2762017: 2,2202018: 2,6632019: 3,3592020: 2,7902021: 2,4422022: 1,7002023: 2,0492024: 1,8492025: 2,306
2007high 3,359 (2019) · low 311 (2008)2025

MAUDE reports naming product code HRS, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200735632339
2008358711311
200947853435
20104910016491
201143885773
20125910641,663
20135689112,643
2014765702,413
2015569773,095
20164410952,276
20175712232,220
20184011622,663
20194689253,359
2020488812,790
2021408792,442
20224714431,700
20234012012,049
2024549601,849
2025549012,306
202651823—

What is it indicated for?

The 2.4 mm Variable Angle LCP Distal Radius System is intended for fixation of complex intra- and extra-articular fractures and osteotomies of the distal radius and other small bones in adults, skeletally mature adolescents, and the following adolescent distal radius fractures: intra-articular fractures exiting the epiphysis, intra-articular fractures exiting the metaphysis, physeal crush injuries, and any injuries which cause growth arrest to the distal…

Read the full statement (454 words)

The 2.4 mm Variable Angle LCP Distal Radius System is intended for fixation of complex intra- and extra-articular fractures and osteotomies of the distal radius and other small bones in adults, skeletally mature adolescents, and the following adolescent distal radius fractures: intra-articular fractures exiting the epiphysis, intra-articular fractures exiting the metaphysis, physeal crush injuries, and any injuries which cause growth arrest to the distal radius.

The 2.4 mm LCP Volar Distal Radius Plates are intended for fixation of complex intra- and extra-articular fractures and osteotomies of the distal radius and other small bones in adults, skeletally mature adolescents, and the following adolescent distal radius fractures: intra-articular fractures exiting the epiphysis, intra-articular fractures exiting the metaphysis, physeal crush injuries, and any injuries which cause growth arrest to the distal radius.

The 2.4 mm Variable Angle LCP Two-Column Volar Distal Radius Plates are intended for fixation of complex intra- and extra-articular fractures and osteotomies of the distal radius and other small bones in adults, skeletally mature adolescents, and the following adolescent distal radius fractures: intra-articular fractures exiting the epiphysis, intra-articular fractures exiting the metaphysis, physeal crush injuries, and any injuries which cause growth arrest to the distal radius.

The 2.4mm Variable Angle LCP Two-Column Narrow Volar Distal Radius Plates are intended for fixation of complex intra- and extra-articular fractures and osteotomies of the distal radius and other small bones in adults, skeletally mature adolescents, and the following adolescent distal radius fractures: intra-articular fractures exiting the epiphysis, intra-articular fractures exiting the metaphysis, physeal crush injuries, and any injuries which cause growth arrest to the distal radius.

The Variable Angle LCP Distal Radius System is intended for fixation of complex intra- and extra-articular fractures and osteotomies of the distal radius and other small bones in adults, skeletally mature adolescents, and the following adolescent distal radius fractures: intra-articular fractures exiting the epiphysis, intra-articular fractures exiting the metaphysis, physeal crush injuries, and any injuries which cause growth arrest to the distal radius.

The Synthes Locking Distal Radius Plating System is intended for fixation of complex intra- and extra-articular fractures and osteotomies of the distal radius and other small bones in adults, skeletally mature adolescents, and the following adolescent distal radius fractures: intra-articular fractures exiting the epiphysis, intra-articular fractures exiting the metaphysis, physeal crush injuries, and any injuries which cause growth arrest to the distal radius.

The Ti-15Mo Locking Distal Radius Plating System Distal System is intended for fixation of complex intra- and extra-articular fractures and osteotomies of the distal radius and other small bones in adults, skeletally mature adolescents, and the following adolescent distal radius fractures: intra-articular fractures exiting the epiphysis, intra-articular fractures exiting the metaphysis, physeal crush injuries, and any injuries which cause growth arrest to the distal radius.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K102694: 2.4MM VA-LCP Dorsal Distal Radius Plates.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K102694

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026