510(k) Report

510(k) · Cleared

Cleared

Wireless/Wired FDR D-Evo Flat Panel Detector

K103596510(k) SpecialCleared Mar 29, 2011111-day reviewClass II21 CFR 892.1680

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Fujifilm Medical Systems U.S.A, Inc. · MQB Solid State X-Ray Imager (Flat Panel/Digital Imager)

Cleared on Mar 29, 2011 as substantially equivalent to K100762 (Fujifilm Medical Systems U.S.A, Inc., 2010) and 1 other predicate after a 111-day review. Its family tree reaches back 7 generations to 1998. 54 later devices descend from it.

Decided
Mar 29, 2011
Review
111 days
Class
Class II
Product code
MQB
Recalls
None
Predicates
2

Its longest line of descent runs back 7 generations to K981556 (1998). 14 ancestors in all. 54 later devices descend from it, 4 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2010: 1 other ancestor2009: 1 other ancestor2004: 1 other ancestor2002: 2 other ancestors2008: 1 other ancestor2003: 1 other ancestor2011: 2 descendants cleared2013: 1 descendant cleared2012: 1 descendant cleared2014: 2 descendants cleared2022: 4 descendants cleared2016: 5 descendants cleared2017: 6 descendants cleared2019: 4 descendants cleared2020: 4 descendants cleared2015: 1 descendant cleared2024: 6 descendants cleared2025: 3 descendants cleared2018: 9 descendants cleared2021: 3 descendants cleared2026: 2 descendants cleared2023: 1 descendant clearedK981556 · Canon X-Ray Digital Camera Cxdi-11 · Canon USA, Inc. · 1998K992547 · Canon X-Ray Digital Camera, Model Cxdi-22 · Canon USA, Inc. · 1999K023750 · Cannon Digital Radiography Model Cxdi-40G · Canon USA, Inc. · 2002K031447 · Canon, Digital Radiography, Model Cxdi-50G · Canon, Inc. · 2003K060433 · Digital Radiography Cxdi-50C · Canon, Inc. · 2006K091545 · Digital Radiography Cxdi-60C · Canon, Inc. · 2009K102012 · Digital Radiography · Canon Inc. -Medical Equipment Group · 2010 · recalled1995200020052010201520202025
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor2 generations back: 3 other ancestors3 generations back: 2 other ancestors4 generations back: 1 other ancestor 1 generation forward: 4 descendants2 generations forward: 3 descendants3 generations forward: 13 descendants4 generations forward: 10 descendants5 generations forward: 4 descendants6 generations forward: 8 descendants7 generations forward: 3 descendants8 generations forward: 3 descendants9 generations forward: 3 descendants10 generations forward: 3 descendants K102012 · Digital Radiography · Canon Inc. -Medical Equipment Group · 2010 · recalledK091545 · Digital Radiography Cxdi-60C · Canon, Inc. · 2009K060433 · Digital Radiography Cxdi-50C · Canon, Inc. · 2006K031447 · Canon, Digital Radiography, Model Cxdi-50G · Canon, Inc. · 2003K023750 · Cannon Digital Radiography Model Cxdi-40G · Canon USA, Inc. · 2002K992547 · Canon X-Ray Digital Camera, Model Cxdi-22 · Canon USA, Inc. · 1999K981556 · Canon X-Ray Digital Camera Cxdi-11 · Canon USA, Inc. · 1998−50+5+10
  1. Root · 7 generations backK981556 Canon X-Ray Digital Camera Cxdi-11Canon USA, Inc. · 1998
  2. 6 generations backK992547 Canon X-Ray Digital Camera, Model Cxdi-22Canon USA, Inc. · 1999
  3. 5 generations backK023750 Cannon Digital Radiography Model Cxdi-40GCanon USA, Inc. · 2002
  4. 4 generations backK031447 Canon, Digital Radiography, Model Cxdi-50GCanon, Inc. · 2003
  5. 3 generations backK060433 Digital Radiography Cxdi-50CCanon, Inc. · 2006
  6. 2 generations backK091545 Digital Radiography Cxdi-60CCanon, Inc. · 2009
  7. 1 generation backK102012 Digital RadiographyCanon Inc. -Medical Equipment Group · 2010 · Recalled
  8. This deviceK103596 Wireless/Wired FDR D-Evo Flat Panel DetectorFujifilm Medical Systems U.S.A, Inc. · 2011
  9. Descendant · cites it directly · 52 of its ownK111548 Wireless/Wired FDR D-Evo Flat Pancel Detector System Model DR-ID600…Fujifilm Medical System U.S.A., Inc. · 2011
  10. Descendant · cites it directly · 50 of its ownK132509 FDR D-Evo Flat Panel Detector SystemFujifilm Medical Systems U.S.A, Inc. · 2013
  11. Descendant · 2 generations on · 32 of its ownK141765 FDR D-Evo Flat Panel Detector SystemFujifilm Medical Systems U.S.A, Inc. · 2014
  12. Descendant · 3 generations on · 26 of its ownK160997 GC85ASamsung Electronics Co., Ltd. · 2016
  13. Descendant · 4 generations on · 23 of its ownK163115 GC70Samsung Electronics Co., Ltd. · 2016

Showing 5 of 54 descendants. See all descendants

Descendants cleared per year

2011: 22012: 12013: 12014: 22015: 12016: 52017: 62018: 92019: 42020: 42021: 32022: 42023: 12024: 62025: 32026: 2
2011high 9 (2018) · low 1 (2012)2026

Most influential descendants

Showing 5 of 54 · See all
  • K111548Wireless/Wired FDR D-Evo Flat Pancel Detector System Model DR-ID600 W/DR-ID611SEFujifilm Medical System U.S.A., Inc. · 2011 · cites it directly52descendants
  • K132509FDR D-Evo Flat Panel Detector SystemFujifilm Medical Systems U.S.A, Inc. · 2013 · cites it directly50descendants
  • K141765FDR D-Evo Flat Panel Detector SystemFujifilm Medical Systems U.S.A, Inc. · 2014 · 2 generations on32descendants
  • K160997GC85ASamsung Electronics Co., Ltd. · 2016 · 3 generations on26descendants
  • K163115GC70Samsung Electronics Co., Ltd. · 2016 · 4 generations on23descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−7K981556Canon X-Ray Digital Camera Cxdi-11Canon USA, Inc.1998—
−6K992547Canon X-Ray Digital Camera, Model Cxdi-22Canon USA, Inc.1999—
−5K023750Cannon Digital Radiography Model Cxdi-40GCanon USA, Inc.2002—
−4K031447Canon, Digital Radiography, Model Cxdi-50GCanon, Inc.2003—
−3K060433Digital Radiography Cxdi-50CCanon, Inc.2006—
−2K091545Digital Radiography Cxdi-60CCanon, Inc.2009—
−1K102012Digital RadiographyCanon Inc. -Medical Equipment Group20101
0 (this device)K103596Wireless/Wired FDR D-Evo Flat Panel DetectorFujifilm Medical Systems U.S.A, Inc.2011—
+1K111548Wireless/Wired FDR D-Evo Flat Pancel Detector System Model DR-ID600 W/DR-ID611SEFujifilm Medical System U.S.A., Inc.2011—
+1K132509FDR D-Evo Flat Panel Detector SystemFujifilm Medical Systems U.S.A, Inc.2013—
+2K141765FDR D-Evo Flat Panel Detector SystemFujifilm Medical Systems U.S.A, Inc.2014—
+3K160997GC85ASamsung Electronics Co., Ltd.2016—
+4K163115GC70Samsung Electronics Co., Ltd.2016—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200220
200310
200410
200810
200910
201010

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201120
201210
201310
201420
201510
201650
201760
201890
201940
202040
202130
202240
202310
202460
202530
202620
FIG. 1 — Lineage of K103596, 1998–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MQB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MQB device

  1. #1 K201528 Yushan X-Ray Flat Panel Detector with DROCscore 21.5 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K100762Flat Panel Detector, Model FDR D-Evo
Summary page 1
…ess/Wired FDR D-EVO flat panel detector system, is a modified version of our currently-cleared predicate device, (wired) FDR D-EVO flat panel detector system (DR-ID600), K100762. The predicate device includes the flat panel sensor (DR-IDB00SE), which provides only a wired communication mode. The FDR D-EVO…
Fujifilm Medical Systems U.S.A, Inc.2010—
*K102012Digital Radiography
Summary page 2
…ate device, (wired) FDR D-EVO system (K100762). In addition, wireless communication specifications are substantially equivalent to the predicate Canon CXDI-70C Wireless (K102012). CONCLUSION— The Wireless/Wired FDR D-EVO flat panel detector system is substantially equivalent to the cleared predicate devic…
Canon Inc. -Medical Equipment Group20101

Also cleared against K100762: 1 other device →

What descends from it? (54)

See all 54

4 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K111548Wireless/Wired FDR D-Evo Flat Pancel Detector System Model DR-ID600 W/DR-ID611SEFujifilm Medical System U.S.A., Inc.201152
K132509FDR D-Evo Flat Panel Detector SystemFujifilm Medical Systems U.S.A, Inc.201350
K120629FDR GO FlexFujifilm Medical System U.S.A., Inc.20120
K111865Wired/ Wireless FDR D-Evo with X-Ray Detection FeatureFujifilm Medical System U.S.A., Inc.20110

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 13 years and passes through 4 companies; a new generation was cleared every 1.2 years on median.
  • 3 of the 14 ancestors have a recall of any class.
  • Of its descendants, K111548 (Fujifilm Medical System U.S.A., Inc., 2011) has gone furthest, with 52 descendants of its own.
  • 1 other device also cites its predicate K100762.

How does its category compare?

All MQB devices

MQB Solid State X-Ray Imager (Flat Panel/Digital Imager): FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.

FDA decisions per year · MQB

8in 2025

2007: 132008: 82009: 152010: 112011: 242012: 222013: 212014: 322015: 212016: 222017: 312018: 162019: 222020: 192021: 212022: 312023: 102024: 82025: 82026 (partial year): 3
2007high 32 (2014) · low 8 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MQB

127in 2025

2007: 22 days median2008: 15 days median2009: 57 days median2010: 116 days median2011: 102 days median2012: 80 days median2013: 105 days median2014: 102 days median2015: 81 days median2016: 92 days median2017: 30 days median2018: 30 days median2019: 30 days median2020: 28 days median2021: 48 days median2022: 48 days median2023: 30 days median2024: 187 days median2025: 127 days median2026 (partial year): 245 days median
2007high 245 (2026) · low 15 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MQB

1in 2025

2007: 152008: 362009: 192010: 142011: 102012: 82013: 62017: 12018: 42019: 12020: 42021: 12025: 12026 (partial year): 1
2007high 36 (2008) · low 0 (2014)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MQB

141in 2025

2007: 252008: 302009: 342010: 392011: 1012012: 2672013: 1592014: 292015: 212016: 262017: 202018: 842019: 452020: 92021: 262022: 132023: 512024: 912025: 141
2007high 267 (2012) · low 9 (2020)2025

MAUDE reports naming product code MQB, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200713221525
20088153630
200915571934
2010111161439
20112410210101
201222808267
2013211056159
201432102029
20152181021
20162292026
20173130120
20181630484
20192230145
2020192849
20212148126
20223148013
20231030051
20248187091
202581271141
202632451—

What is it indicated for?

The Wireless/Wired FDR D-EVO flat panel detector system is intended to capture for display radiographic images of human anatomy. It is intended for use in general projection radiographic applications wherever conventional film/screen or CR systems may be used. The FDR D-EVO is not intended for mammography, fluoroscopy, tomography, and angiography applications.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K103596: Wireless/Wired FDR D-Evo Flat Panel Detector.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K103596

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026