510(k) · Cleared
ClearedGC70
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Samsung Electronics Co., Ltd. · KPR System, X-Ray, Stationary
Cleared on Dec 7, 2016 as substantially equivalent to K160997 (Samsung Electronics Co., Ltd., 2016) after a 30-day review. Its family tree reaches back 12 generations to 1998. 23 later devices descend from it.
- Decided
- Dec 7, 2016
- Review
- 30 days
- Class
- Class II
- Product code
- KPR
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 12 generations to K981556 (1998). 30 ancestors in all, the oldest K862120 (1986). 23 later devices descend from it, 2 citing it directly.
- Root · 12 generations backK981556 Canon X-Ray Digital Camera Cxdi-11Canon USA, Inc. · 1998
- 8 generations between
- 3 generations backK132509 FDR D-Evo Flat Panel Detector SystemFujifilm Medical Systems U.S.A, Inc. · 2013
- 2 generations backK141765 FDR D-Evo Flat Panel Detector SystemFujifilm Medical Systems U.S.A, Inc. · 2014
- 1 generation backK160997 GC85ASamsung Electronics Co., Ltd. · 2016
- This deviceK163115 GC70Samsung Electronics Co., Ltd. · 2016
- Descendant · cites it directly · 22 of its ownK171119 GM85Samsung Electronics Co., Ltd. · 2017 · Recalled
- Descendant · 2 generations on · 19 of its ownK173828 GU60A & GU60A-65Samsung Electronics Co., Ltd. · 2018
- Descendant · cites it directly · 18 of its ownK180543 GC70, GU60A&GU60A-65, GF50, GF50A, GR40CW, and GM85Samsung Electronics Co., Ltd. · 2018
- Descendant · 2 generations on · 10 of its ownK181626 Digital Diagnostic Mobile X-ray SystemSamsung Electronics Co., Ltd. · 2018
- Descendant · 2 generations on · 5 of its ownK181629 GC85ASamsung Electronics Co., Ltd. · 2018
Show all 12 generations
- Root · 12 generations backK981556 Canon X-Ray Digital Camera Cxdi-11Canon USA, Inc. · 1998
- 11 generations backK992547 Canon X-Ray Digital Camera, Model Cxdi-22Canon USA, Inc. · 1999
- 10 generations backK023750 Cannon Digital Radiography Model Cxdi-40GCanon USA, Inc. · 2002
- 9 generations backK031447 Canon, Digital Radiography, Model Cxdi-50GCanon, Inc. · 2003
- 8 generations backK060433 Digital Radiography Cxdi-50CCanon, Inc. · 2006
- 7 generations backK091545 Digital Radiography Cxdi-60CCanon, Inc. · 2009
- 6 generations backK102012 Digital RadiographyCanon Inc. -Medical Equipment Group · 2010 · Recalled
- 5 generations backK103596 Wireless/Wired FDR D-Evo Flat Panel DetectorFujifilm Medical Systems U.S.A, Inc. · 2011
- 4 generations backK111548 Wireless/Wired FDR D-Evo Flat Pancel Detector System Model DR-ID600…Fujifilm Medical System U.S.A., Inc. · 2011
- 3 generations backK132509 FDR D-Evo Flat Panel Detector SystemFujifilm Medical Systems U.S.A, Inc. · 2013
- 2 generations backK141765 FDR D-Evo Flat Panel Detector SystemFujifilm Medical Systems U.S.A, Inc. · 2014
- 1 generation backK160997 GC85ASamsung Electronics Co., Ltd. · 2016
- This deviceK163115 GC70Samsung Electronics Co., Ltd. · 2016
Showing 5 of 23 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 23 · See all- K171119GM85Samsung Electronics Co., Ltd. · 2017 · cites it directly22descendants
- K173828GU60A & GU60A-65Samsung Electronics Co., Ltd. · 2018 · 2 generations on19descendants
- K180543GC70, GU60A&GU60A-65, GF50, GF50A, GR40CW, and GM85Samsung Electronics Co., Ltd. · 2018 · cites it directly18descendants
- K181626Digital Diagnostic Mobile X-ray SystemSamsung Electronics Co., Ltd. · 2018 · 2 generations on10descendants
- K181629GC85ASamsung Electronics Co., Ltd. · 2018 · 2 generations on5descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −12 | K981556 | Canon X-Ray Digital Camera Cxdi-11 | Canon USA, Inc. | 1998 | — |
| −11 | K992547 | Canon X-Ray Digital Camera, Model Cxdi-22 | Canon USA, Inc. | 1999 | — |
| −10 | K023750 | Cannon Digital Radiography Model Cxdi-40G | Canon USA, Inc. | 2002 | — |
| −9 | K031447 | Canon, Digital Radiography, Model Cxdi-50G | Canon, Inc. | 2003 | — |
| −8 | K060433 | Digital Radiography Cxdi-50C | Canon, Inc. | 2006 | — |
| −7 | K091545 | Digital Radiography Cxdi-60C | Canon, Inc. | 2009 | — |
| −6 | K102012 | Digital Radiography | Canon Inc. -Medical Equipment Group | 2010 | 1 |
| −5 | K103596 | Wireless/Wired FDR D-Evo Flat Panel Detector | Fujifilm Medical Systems U.S.A, Inc. | 2011 | — |
| −4 | K111548 | Wireless/Wired FDR D-Evo Flat Pancel Detector System Model DR-ID600 W/DR-ID611SE | Fujifilm Medical System U.S.A., Inc. | 2011 | — |
| −3 | K132509 | FDR D-Evo Flat Panel Detector System | Fujifilm Medical Systems U.S.A, Inc. | 2013 | — |
| −2 | K141765 | FDR D-Evo Flat Panel Detector System | Fujifilm Medical Systems U.S.A, Inc. | 2014 | — |
| −1 | K160997 | GC85A | Samsung Electronics Co., Ltd. | 2016 | — |
| 0 (this device) | K163115 | GC70 | Samsung Electronics Co., Ltd. | 2016 | — |
| +1 | K171119 | GM85 | Samsung Electronics Co., Ltd. | 2017 | 1 |
| +2 | K173828 | GU60A & GU60A-65 | Samsung Electronics Co., Ltd. | 2018 | — |
| +1 | K180543 | GC70, GU60A&GU60A-65, GF50, GF50A, GR40CW, and GM85 | Samsung Electronics Co., Ltd. | 2018 | — |
| +2 | K181626 | Digital Diagnostic Mobile X-ray System | Samsung Electronics Co., Ltd. | 2018 | — |
| +2 | K181629 | GC85A | Samsung Electronics Co., Ltd. | 2018 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1986 | 1 | 0 |
| 1988 | 1 | 0 |
| 1998 | 1 | 0 |
| 1999 | 1 | 0 |
| 2001 | 1 | 0 |
| 2002 | 2 | 0 |
| 2003 | 1 | 0 |
| 2004 | 1 | 0 |
| 2005 | 1 | 0 |
| 2008 | 1 | 0 |
| 2009 | 2 | 0 |
| 2010 | 1 | 0 |
| 2013 | 1 | 0 |
| 2014 | 1 | 0 |
| 2015 | 2 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2017 | 1 | 0 |
| 2018 | 8 | 0 |
| 2019 | 1 | 0 |
| 2020 | 1 | 0 |
| 2021 | 2 | 0 |
| 2022 | 2 | 0 |
| 2023 | 1 | 0 |
| 2024 | 4 | 0 |
| 2025 | 1 | 0 |
| 2026 | 2 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in KPR? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new KPR device
- #1 K242119 Innovision-Exiiscore 17.0 · 9 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K160997 | GC85ASummary page 4…igital Diagnostic X-ray System D. Classification Name: Stationary x-ray system E. Product Code: KPR F. Regulation: 21 CFR 892.1680 G. 510(k): K160997 7. Device Description The GC70 digital X-ray imaging system is used to capture images by transmitting X-ray… | 2016 |
What descends from it? (23)
See all 232 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 18 years and passes through 6 companies; a new generation was cleared every 1.2 years on median.
- 9 of the 30 ancestors have a recall of any class.
- Of its descendants, K171119 (Samsung Electronics Co., Ltd., 2017) has gone furthest, with 22 descendants of its own.
- 2 other devices also cite its predicate K160997.
How does its category compare?
All KPR devicesKPR System, X-Ray, Stationary: FDA decisions, review times, recalls and adverse event reports over 20 years. 2016, this device’s year, is highlighted.
FDA decisions per year · KPR
8in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · KPR
155in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · KPR
7in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · KPR
39in 2025
MAUDE reports naming product code KPR, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 12 | 31 | 10 | 120 |
| 2008 | 15 | 48 | 10 | 95 |
| 2009 | 9 | 35 | 5 | 61 |
| 2010 | 9 | 126 | 3 | 82 |
| 2011 | 9 | 152 | 5 | 103 |
| 2012 | 11 | 58 | 1 | 74 |
| 2013 | 5 | 163 | 5 | 24 |
| 2014 | 10 | 108 | 8 | 34 |
| 2015 | 18 | 81 | 1 | 59 |
| 2016 | 11 | 84 | 4 | 18 |
| 2017 | 6 | 75 | 3 | 31 |
| 2018 | 15 | 30 | 4 | 36 |
| 2019 | 12 | 33 | 1 | 77 |
| 2020 | 16 | 39 | 1 | 41 |
| 2021 | 6 | 55 | 0 | 37 |
| 2022 | 8 | 43 | 2 | 27 |
| 2023 | 9 | 76 | 4 | 39 |
| 2024 | 11 | 162 | 1 | 34 |
| 2025 | 8 | 155 | 7 | 39 |
| 2026 | 6 | 197 | 0 | — |
What is it indicated for?
The GC70 Digital X-ray Imaging System is intended for use in generating radiographic images of human anatomy by a qualified/trained doctor or technician. This device is not intended for mammographic applications.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K163115 · printed Nov 6, 2026
Cite this page
510(k) Report. “K163115: GC70.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K163115
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026