510(k) Report

510(k) · Cleared

Cleared

QA-40M Defibrillator Tester

K963190510(k) TraditionalCleared Jul 1, 1997320-day reviewClass II21 CFR 870.5325

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Metron U.S., Inc. · DRL Tester, Defibrillator

Cleared on Jul 1, 1997 after a 320-day review. FDA’s file for it is a 510(k) statement, which names no predicate. 2 later devices descend from it.

Decided
Jul 1, 1997
Review
320 days
Class
Class II
Product code
DRL
Recalls
None
Predicates
0

2 later devices descend from it, 1 citing it directly.

Descendants, by year cleared 2011: 1 descendant cleared2019: 1 descendant cleared1995200020052010201520202025
  1. This deviceK963190 QA-40M Defibrillator TesterMetron U.S., Inc. · 1997
  2. Descendant · cites it directly · 1 of its ownK110192 Defibrillator Analyzer - DA-2006PBc Group International, Inc. · 2011 · Recalled
  3. Descendant · 2 generations on · 0 of its ownK190437 Delta 3300Netech Corporation · 2019

Most influential descendants

Showing 2 of 2 · See all
  • K110192Defibrillator Analyzer - DA-2006PBc Group International, Inc. · 2011 · cites it directly1descendant
  • K190437Delta 3300Netech Corporation · 2019 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K963190QA-40M Defibrillator TesterMetron U.S., Inc.1997—
+1K110192Defibrillator Analyzer - DA-2006PBc Group International, Inc.20111
+2K190437Delta 3300Netech Corporation2019—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201110
201910
FIG. 1 — Lineage of K963190, 1997–2019Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DRL? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K110192Defibrillator Analyzer - DA-2006PBc Group International, Inc.20111

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K110192 (Bc Group International, Inc., 2011) has gone furthest, with 1 descendant of its own.

How does its category compare?

All DRL devices

DRL Tester, Defibrillator: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · DRL

1in 2019

2007: 12008: 22011: 12015: 12018: 12019: 1
2007high 2 (2008) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DRL

Too few DRL 510(k)s in any year since 2007 to give a median.

Recalls per year · DRL

1in 2015

2015: 1
2007high 1 (2015) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DRL

2in 2013

2009: 12013: 2
2007high 2 (2013) · low 0 (2007)2025

MAUDE reports naming product code DRL, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—00
20082—00
20090—01
20100—00
20111—00
20120—00
20130—02
20140—00
20151—10
20160—00
20170—00
20181—00
20191—00
20200—00
20210—00
20220—00
20230—00
20240—00
20250—00
20260—0—

What is it indicated for?

The Metron U.S. Q4-40M Defibrillator Analyzer is a precision instrument for testing defibrillators, and for ensuring that defibrillators comply with the specified requirements. The QA4-40M tester is a device that is connected to the output of a defibrillator and is used to measure the energy delivered by the defibrillator into a standard resistive load and can also provide waveform information. The Q4-40M test for ANSI/AAMI DF39 standards. The QA4-40M…

Read the full statement (208 words)

The Metron U.S. Q4-40M Defibrillator Analyzer is a precision instrument for testing defibrillators, and for ensuring that defibrillators comply with the specified requirements.

The QA4-40M tester is a device that is connected to the output of a defibrillator and is used to measure the energy delivered by the defibrillator into a standard resistive load and can also provide waveform information. The Q4-40M test for ANSI/AAMI DF39 standards.

The QA4-40M Defibrillator Analyzer's main function is to measure the energy output of a defibrillator. The instrument has a built-in load resistance of 50 ohm, which roughly corresponds to the impedance of the human body. The defibrillator pads are placed on the QA-40M contact plates. Thus, the defibrillator is connected through load resistance. When the defibrillator is discharged, Q4-40M will calculate and display the energy delivered.

The QA-40M Defibrillator Analyzer performs the following tests and features (1) energy and cardioversion measurement, (2) peak voltage and current reading, (3) storage and playback of output waveform, (4) 12 lead ECG simulation. (§) ECG, performance and arrhythmia simulation, (6) transcutaneous cardiac pacemaker testing ( module is optional), (7) integrated pacemaker loads selectable from 50 ohm to 2500 ohm, (8) automatic defibrillator test procedures, (9) large graphic display and (10) RS-232C and Centronic printer interface.

Indications for use read by OCR from a scanned FDA 510(k) statement, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K963190: QA-40M Defibrillator Tester.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K963190

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026