510(k) · Cleared
ClearedProphecy Inbone Pre-Operative Navigation Alignment Guides
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Wrightmedicaltechnologyinc · HSN Prosthesis, Ankle, Semi-Constrained, Cemented, Metal/Polymer
Cleared on Dec 16, 2011 as substantially equivalent to K051023 (Topez Orthopedics, Inc., 2005) after a 311-day review. Its family tree reaches back 3 generations to 1992. 19 later devices descend from it.
- Decided
- Dec 16, 2011
- Review
- 311 days
- Class
- Class II
- Product code
- HSN
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 3 generations to K920802 (1992). 19 later devices descend from it, 4 citing it directly.
- Root · 3 generations backK920802 Alvine Total AnkleDepuy, Inc. · 1992
- 2 generations backK020541 Agility Ankle Revision ProsthesisDepuy, Inc. · 2002
- 1 generation backK051023 Topez Total Ankle ReplacementTopez Orthopedics, Inc. · 2005 · Recalled
- This deviceK110360 Prophecy Inbone Pre-Operative Navigation Alignment GuidesWrightmedicaltechnologyinc · 2011
- Descendant · cites it directly · 18 of its ownK131283 Prophecy Infinity Preoperative Navigation Alignment GuidesWrightmedicaltechnologyinc · 2013
- Descendant · cites it directly · 17 of its ownK162795 PROPHECY INVISION Preoperative Navigation Alignment SystemWrightmedicaltechnologyinc · 2017
- Descendant · cites it directly · 16 of its ownK170968 PROPHECY INVISION Pre-operative Navigation SystemWrightmedicaltechnologyinc · 2017
- Descendant · 2 generations on · 6 of its ownK193432 Vantage PSI System3D Systems · 2020
- Descendant · cites it directly · 3 of its ownK202815 PROPHECY Preoperative Navigation Alignment SystemWrightmedicaltechnologyinc · 2021
Showing 5 of 19 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 19 · See all- K131283Prophecy Infinity Preoperative Navigation Alignment GuidesWrightmedicaltechnologyinc · 2013 · cites it directly18descendants
- K162795PROPHECY INVISION Preoperative Navigation Alignment SystemWrightmedicaltechnologyinc · 2017 · cites it directly17descendants
- K170968PROPHECY INVISION Pre-operative Navigation SystemWrightmedicaltechnologyinc · 2017 · cites it directly16descendants
- K193432Vantage PSI System3D Systems · 2020 · 2 generations on6descendants
- K202815PROPHECY Preoperative Navigation Alignment SystemWrightmedicaltechnologyinc · 2021 · cites it directly3descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −3 | K920802 | Alvine Total Ankle | Depuy, Inc. | 1992 | — |
| −2 | K020541 | Agility Ankle Revision Prosthesis | Depuy, Inc. | 2002 | — |
| −1 | K051023 | Topez Total Ankle Replacement | Topez Orthopedics, Inc. | 2005 | 4 |
| 0 (this device) | K110360 | Prophecy Inbone Pre-Operative Navigation Alignment Guides | Wrightmedicaltechnologyinc | 2011 | — |
| +1 | K131283 | Prophecy Infinity Preoperative Navigation Alignment Guides | Wrightmedicaltechnologyinc | 2013 | — |
| +1 | K162795 | PROPHECY INVISION Preoperative Navigation Alignment System | Wrightmedicaltechnologyinc | 2017 | — |
| +1 | K170968 | PROPHECY INVISION Pre-operative Navigation System | Wrightmedicaltechnologyinc | 2017 | — |
| +2 | K193432 | Vantage PSI System | 3D Systems | 2020 | — |
| +1 | K202815 | PROPHECY Preoperative Navigation Alignment System | Wrightmedicaltechnologyinc | 2021 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2013 | 1 | 0 |
| 2017 | 2 | 0 |
| 2020 | 1 | 0 |
| 2021 | 3 | 0 |
| 2022 | 1 | 0 |
| 2023 | 4 | 0 |
| 2024 | 6 | 0 |
| 2026 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in HSN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new HSN device
- #1 K192994 Paragon 28 APEX 3D Total Ankle Replacement…score 16.7 · 8 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K051023 | Topez Total Ankle Replacement | 2005 |
What descends from it? (19)
See all 194 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 19 years and passes through 3 companies; a new generation was cleared every 6.1 years on median.
- 1 of the 3 ancestors has a recall of any class.
- Of its descendants, K131283 (Wrightmedicaltechnologyinc, 2013) has gone furthest, with 18 descendants of its own.
- 8 other devices also cite its predicate K051023.
How does its category compare?
All HSN devicesHSN Prosthesis, Ankle, Semi-Constrained, Cemented, Metal/Polymer: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.
FDA decisions per year · HSN
3in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · HSN
58in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · HSN
1in 2023
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · HSN
1,645in 2025
MAUDE reports naming product code HSN, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 50 |
| 2008 | 0 | — | 0 | 66 |
| 2009 | 1 | — | 0 | 66 |
| 2010 | 2 | — | 0 | 120 |
| 2011 | 1 | — | 0 | 139 |
| 2012 | 2 | — | 0 | 100 |
| 2013 | 4 | 89 | 3 | 106 |
| 2014 | 2 | — | 0 | 65 |
| 2015 | 3 | 233 | 0 | 73 |
| 2016 | 3 | 216 | 1 | 111 |
| 2017 | 4 | 148 | 2 | 96 |
| 2018 | 4 | 89 | 0 | 187 |
| 2019 | 2 | — | 1 | 277 |
| 2020 | 6 | 234 | 0 | 281 |
| 2021 | 4 | 109 | 3 | 237 |
| 2022 | 1 | — | 2 | 453 |
| 2023 | 6 | 112 | 1 | 796 |
| 2024 | 7 | 115 | 0 | 1,095 |
| 2025 | 3 | 58 | 0 | 1,645 |
| 2026 | 2 | — | 0 | — |
What is it indicated for?
Wright's PROPHECY® INBONE® Pre-Operative Navigation Alignment Guides are intended to be used as patient-specific surgical instrumentation to assist in the positioning of total ankle replacement components intra-operatively and in guiding the marking of bone before cutting. The PROPHECY® INBONE® Pre-Operative Navigation Alignment Guides are intended for use with Wright's INBONE® Total Ankle Systems and their cleared indications for use, provided that anatomic landmarks necessary for alignment and positioning of the implant are identifiable on patient imaging scans. The PROPHECY® INBONE® Pre-Operative Navigation Alignment Guides are intended for single use only.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K110360 · printed Nov 6, 2026
Cite this page
510(k) Report. “K110360: Prophecy Inbone Pre-Operative Navigation Alignment Guides.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K110360
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026