510(k) · Cleared
ClearedSensilase Pad-IQ
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Vasamed, Inc. · DPW Flowmeter, Blood, Cardiovascular
Cleared on May 4, 2011 as substantially equivalent to K040654 (Optical Sensors, Inc., 2004) after a 78-day review. Its family tree reaches back 2 generations to 1995.
- Decided
- May 4, 2011
- Review
- 78 days
- Class
- Class II
- Product code
- DPW
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 2 generations to K951486 (1995). No later device cites it as a predicate yet.
View FIG. 1 as a table
Line of descent and top descendants
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in DPW? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new DPW device
- #1 K251114 FloPatch FP120score 13.7 · 5 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K040654 | Sensilase Pad 3000Summary page 1…1, Product Code: DPW Predicate IDev ice: 5 10(k) Number: K(040654 Mlarufhture: Vasamned Incorporated… | 2004 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 16 years and passes through 3 companies; a new generation was cleared every 8.9 years on median.
- None of the 2 ancestors has a recall.
How does its category compare?
All DPW devicesDPW Flowmeter, Blood, Cardiovascular: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.
FDA decisions per year · DPW
3in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · DPW
119in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · DPW
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · DPW
6in 2025
MAUDE reports naming product code DPW, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 1 | — | 4 | 0 |
| 2008 | 1 | — | 0 | 0 |
| 2009 | 0 | — | 0 | 1 |
| 2010 | 2 | — | 1 | 0 |
| 2011 | 4 | 89 | 0 | 1 |
| 2012 | 1 | — | 1 | 0 |
| 2013 | 2 | — | 0 | 3 |
| 2014 | 0 | — | 0 | 8 |
| 2015 | 3 | 275 | 0 | 12 |
| 2016 | 1 | — | 0 | 1 |
| 2017 | 0 | — | 1 | 2 |
| 2018 | 2 | — | 0 | 0 |
| 2019 | 3 | 169 | 0 | 3 |
| 2020 | 2 | — | 0 | 4 |
| 2021 | 2 | — | 0 | 6 |
| 2022 | 3 | 136 | 0 | 1 |
| 2023 | 1 | — | 0 | 2 |
| 2024 | 1 | — | 0 | 4 |
| 2025 | 3 | 119 | 1 | 6 |
| 2026 | 2 | — | 0 | — |
What is it indicated for?
The SensiLase® PAD-IQ provides a noninvasive measurement of Skin Perfusion Pressure (SPP) and Pulse Volume Recording (PVR) waveforms on extremities of patients.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K110438 · printed Nov 6, 2026
Cite this page
510(k) Report. “K110438: Sensilase Pad-IQ.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K110438
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026