Kalare Diagnostic X-Ray Table System

K110785510(k) TraditionalCleared May 27, 201167-day reviewClass II21 CFR 892.1650Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Toshiba Medical Systems Coporation, Japan · JAA System, X-Ray, Fluoroscopic, Image-Intensified

Cleared on May 27, 2011 as substantially equivalent to K081091 (GE Healthcare, 2008) after a 67-day review. Its family tree reaches back 3 generations to 1986. 2 later devices descend from it. It has been recalled once.

Decided
May 27, 2011
Review
67 days
Class
Class II
Product code
JAA
Recalls
1
Predicates
1

Its longest line of descent runs back 3 generations to K862120 (1986). 5 ancestors in all. 2 later devices descend from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 1997: 1 other ancestor1996: 1 other ancestor2014: 1 descendant cleared2015: 1 descendant clearedK862120 · SCX System · General Electric Co. · 1986 · recalledK011624 · Expedio 500D R&F X-Ray System · GE Medical Systems · 2001 · recalledK081091 · Precision 500D R&F X-Ray System · GE Healthcare · 2008 · recalled1990200020102020
Other ancestors, by generationDescendants, by generation 3 generations back: 2 other ancestors 1 generation forward: 1 descendant2 generations forward: 1 descendant K081091 · Precision 500D R&F X-Ray System · GE Healthcare · 2008 · recalledK011624 · Expedio 500D R&F X-Ray System · GE Medical Systems · 2001 · recalledK862120 · SCX System · General Electric Co. · 1986 · recalled0
  1. Root · 3 generations backK862120 SCX SystemGeneral Electric Co. · 1986 · Recalled
  2. 2 generations backK011624 Expedio 500D R&F X-Ray SystemGE Medical Systems · 2001 · Recalled
  3. 1 generation backK081091 Precision 500D R&F X-Ray SystemGE Healthcare · 2008 · Recalled
  4. This deviceK110785 Kalare Diagnostic X-Ray Table SystemToshiba Medical Systems Coporation, Japan · 2011
  5. Descendant · cites it directly · 1 of its ownK133553 KalareToshiba America Medical Systems, In.C · 2014 · Recalled
  6. Descendant · 2 generations on · 0 of its ownK143281 Ultimax-iToshibamedical Systems Corporation · 2015

Most influential descendants

Showing 2 of 2 · See all
  • K133553KalareToshiba America Medical Systems, In.C · 2014 · cites it directly1descendant
  • K143281Ultimax-iToshibamedical Systems Corporation · 2015 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K862120SCX SystemGeneral Electric Co.19863
−2K011624Expedio 500D R&F X-Ray SystemGE Medical Systems200111
−1K081091Precision 500D R&F X-Ray SystemGE Healthcare20089
0 (this device)K110785Kalare Diagnostic X-Ray Table SystemToshiba Medical Systems Coporation, Japan2011—
+1K133553KalareToshiba America Medical Systems, In.C20143
+2K143281Ultimax-iToshibamedical Systems Corporation2015—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199610
199710

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201410
201510
FIG. 1 — Lineage of K110785, 1986–2015Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JAA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JAA device

  1. #1 K253103 Nexus DRF Digital X-ray Imaging Systemscore 13.2 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K081091Precision 500D R&F X-Ray System
Summary page 2
…KALARE (DREX-KLSO) 11. SUBSTANTIAL EQUIVALENCE: The KALARE (OREX-KL8O) is of comparable type and is substantially equivalent to the GE Precision 500D R&F X-ray (K081091). 12. SAFETY: The device is designed and manufactured under the Quality System Regulations as outlined in 21 CFR § 820 a…
GE Healthcare20089

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K133553KalareToshiba America Medical Systems, In.C20141

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Apr 3, 2013Class IIZ-1598-2013Component design/selectionFirm initiated recall because when radiographic conditions with the small focus are set and the radiography ready switch is held down, the large focus is also heated after a few seconds or more. This occurs when the Automatic Exposure…

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 25 years and passes through 4 companies; a new generation was cleared every 7.0 years on median.
  • 4 of the 5 ancestors have a recall of any class.
  • Of its descendants, K133553 (Toshiba America Medical Systems, In.C, 2014) has gone furthest, with 1 descendant of its own.

How does its category compare?

All JAA devices

JAA System, X-Ray, Fluoroscopic, Image-Intensified: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.

FDA decisions per year · JAA

2in 2025

2007: 12008: 62010: 12011: 42012: 12013: 62014: 62015: 32016: 22017: 12018: 32019: 62020: 42021: 62022: 12023: 22024: 32025: 22026 (partial year): 1
2007high 6 (2008) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JAA

89in 2024

2008: 18 days median2011: 48 days median2013: 129 days median2014: 276 days median2015: 197 days median2018: 30 days median2019: 49 days median2020: 39 days median2021: 104 days median2024: 89 days median
2007high 276 (2014) · low 18 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JAA

4in 2025

2007: 352008: 212009: 182010: 62011: 72012: 22013: 32014: 12015: 12016: 72017: 32018: 12019: 22020: 22021: 22022: 52023: 92024: 22025: 4
2007high 35 (2007) · low 1 (2014)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JAA

33in 2025

2007: 9,5172008: 9,4842009: 12,0402010: 5,8032011: 14,0002012: 11,6842013: 13,7062014: 10,2652015: 2,9222016: 352017: 562018: 362019: 492020: 392021: 352022: 342023: 412024: 252025: 33
2007high 14,000 (2011) · low 25 (2024)2025

MAUDE reports naming product code JAA, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—359,517
2008618219,484
20090—1812,040
20101—65,803
2011448714,000
20121—211,684
20136129313,706
20146276110,265
2015319712,922
20162—735
20171—356
2018330136
2019649249
2020439239
20216104235
20221—534
20232—941
2024389225
20252—433
20261—0—

What is it indicated for?

1. Intended to be used as a universal diagnostic imaging system for radiographic and fluoroscopic examinations, including general R&F and pediatric examinations.

2. Intended for use by a qualified/trained doctor or technologist on both adult and pediatric subjects taking diagnostic radiographic and fluoroscopic exposures of the whole body. skull, spinal column, chest, abdomen, extremities-and other body parts. Applications can be performed with the patient sitting, standing or lying in the prone or supine position.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K110785: Kalare Diagnostic X-Ray Table System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K110785

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026