510(k) Report

510(k) · Cleared

Cleared

Zoll Rescuenetlink

K111296510(k) TraditionalCleared Oct 27, 2011171-day reviewClass II21 CFR 870.2300

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Zoll Medical Corporation, World Wide Headquarters · MSX System, Network And Communication, Physiological Monitors

Cleared on Oct 27, 2011 as substantially equivalent to K102757 (Physio-Control, Inc., 2010) after a 171-day review. Its family tree reaches back 5 generations to 1997. 5 later devices descend from it.

Decided
Oct 27, 2011
Review
171 days
Class
Class II
Product code
MSX
Recalls
None
Predicates
1

Its longest line of descent runs back 5 generations to K971723 (1997). 6 ancestors in all. 5 later devices descend from it, 2 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2000: 1 other ancestor2014: 3 descendants cleared2021: 1 descendant cleared2024: 1 descendant clearedK971723 · Fastak Suture Anchor (11.7MM)/(7.5MM) · Arthrex, Inc. · 1997K051219 · Pushlock · Arthrex, Inc. · 2005K073509 · Twinfix PK FP Suture Anchor · Smith & Nephew, Inc. · 2008K093925 · Lifenet System · Physio-Control, Inc. · 2010K102757 · Lifenet System · Physio-Control, Inc. · 20101995200020052010201520202025
Other ancestors, by generationDescendants, by generation 5 generations back: 1 other ancestor 1 generation forward: 2 descendants2 generations forward: 2 descendants3 generations forward: 1 descendant K102757 · Lifenet System · Physio-Control, Inc. · 2010K093925 · Lifenet System · Physio-Control, Inc. · 2010K073509 · Twinfix PK FP Suture Anchor · Smith & Nephew, Inc. · 2008K051219 · Pushlock · Arthrex, Inc. · 2005K971723 · Fastak Suture Anchor (11.7MM)/(7.5MM) · Arthrex, Inc. · 1997−50
  1. Root · 5 generations backK971723 Fastak Suture Anchor (11.7MM)/(7.5MM)Arthrex, Inc. · 1997
  2. 4 generations backK051219 PushlockArthrex, Inc. · 2005
  3. 3 generations backK073509 Twinfix PK FP Suture AnchorSmith & Nephew, Inc. · 2008
  4. 2 generations backK093925 Lifenet SystemPhysio-Control, Inc. · 2010
  5. 1 generation backK102757 Lifenet SystemPhysio-Control, Inc. · 2010
  6. This deviceK111296 Zoll RescuenetlinkZoll Medical Corporation, World Wide Headquarters · 2011
  7. Descendant · cites it directly · 2 of its ownK141774 Zoll X SeriesZOLL Medical Corporation · 2014
  8. Descendant · 2 generations on · 1 of its ownK202375 ZOLL Propaq MZOLL Medical Corporation · 2021
  9. Descendant · cites it directly · 1 of its ownK133484 Zoll X SeriesZoll Medical Corp · 2014
  10. Descendant · 3 generations on · 0 of its ownK233354 WVSM Pro (Series) (500-0030-XX)Athena Gtx, Inc. · 2024
  11. Descendant · 2 generations on · 0 of its ownK142915 ZOLL X SeriesZOLL Medical Corporation · 2014

Most influential descendants

Showing 5 of 5 · See all
  • K141774Zoll X SeriesZOLL Medical Corporation · 2014 · cites it directly2descendants
  • K202375ZOLL Propaq MZOLL Medical Corporation · 2021 · 2 generations on1descendant
  • K133484Zoll X SeriesZoll Medical Corp · 2014 · cites it directly1descendant
  • K233354WVSM Pro (Series) (500-0030-XX)Athena Gtx, Inc. · 2024 · 3 generations on0descendants
  • K142915ZOLL X SeriesZOLL Medical Corporation · 2014 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K971723Fastak Suture Anchor (11.7MM)/(7.5MM)Arthrex, Inc.1997—
−4K051219PushlockArthrex, Inc.2005—
−3K073509Twinfix PK FP Suture AnchorSmith & Nephew, Inc.2008—
−2K093925Lifenet SystemPhysio-Control, Inc.2010—
−1K102757Lifenet SystemPhysio-Control, Inc.2010—
0 (this device)K111296Zoll RescuenetlinkZoll Medical Corporation, World Wide Headquarters2011—
+1K141774Zoll X SeriesZOLL Medical Corporation2014—
+2K202375ZOLL Propaq MZOLL Medical Corporation2021—
+1K133484Zoll X SeriesZoll Medical Corp2014—
+3K233354WVSM Pro (Series) (500-0030-XX)Athena Gtx, Inc.2024—
+2K142915ZOLL X SeriesZOLL Medical Corporation2014—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200010

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201430
202110
202410
FIG. 1 — Lineage of K111296, 1997–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MSX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MSX device

  1. #1 K242750 Central Stationscore 21.5 · 31 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K102757Lifenet System
Summary page 7
…and functions of the proposed RescueNet Link are substantially equivalent to the corresponding features and functions of the Physio-Control LIFENET System (K1 02757, cleared for use on 11/5/2010). Comparison of Technological Characteristics RescueNet Link features and functions are simil…
Physio-Control, Inc.2010—

Also cleared against K102757: 1 other device →

What descends from it? (5)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K141774Zoll X SeriesZOLL Medical Corporation20142
K133484Zoll X SeriesZoll Medical Corp20141

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 14 years and passes through 4 companies; a new generation was cleared every 1.9 years on median.
  • None of the 6 ancestors has a recall.
  • Of its descendants, K141774 (ZOLL Medical Corporation, 2014) has gone furthest, with 2 descendants of its own.
  • 1 other device also cites its predicate K102757.

How does its category compare?

All MSX devices

MSX System, Network And Communication, Physiological Monitors: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.

FDA decisions per year · MSX

4in 2025

2007: 42008: 12009: 12010: 32011: 72012: 42013: 22014: 32015: 52016: 32017: 22018: 42019: 42020: 52021: 32022: 52023: 32024: 42025: 42026 (partial year): 5
2007high 7 (2011) · low 1 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MSX

295in 2025

2007: 58 days median2010: 43 days median2011: 72 days median2012: 145 days median2014: 165 days median2015: 138 days median2016: 174 days median2018: 111 days median2019: 92 days median2020: 193 days median2021: 227 days median2022: 177 days median2023: 244 days median2024: 212 days median2025: 295 days median2026 (partial year): 145 days median
2007high 295 (2025) · low 43 (2010)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MSX

1in 2025

2007: 12008: 12009: 22010: 12011: 12012: 22015: 22017: 22018: 12022: 12025: 12026 (partial year): 2
2007high 2 (2009) · low 0 (2013)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MSX

19in 2025

2007: 52008: 62009: 72010: 142011: 32012: 42013: 172014: 322015: 312016: 112017: 162018: 152019: 152020: 252021: 172022: 182023: 102024: 322025: 19
2007high 32 (2014) · low 3 (2011)2025

MAUDE reports naming product code MSX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200745815
20081—16
20091—27
2010343114
201177213
2012414524
20132—017
20143165032
20155138231
20163174011
20172—216
20184111115
2019492015
20205193025
20213227017
20225177118
20233244010
20244212032
20254295119
202651452—

What is it indicated for?

RescueNet Link is intended for use in the collection and display of data that is entered by a user (caregiver), or captured from specified medical devices or from a vehicle navigation system. RescueNet Link is indicated for use by health care providers whenever there is a need for collection and display of patient, care reporting and transport data.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K111296: Zoll Rescuenetlink.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K111296

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026