ClearedBD Nexiva Diffusics Closed IV Catheter System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Becton, Dickinson and Company (BD) · FOZ Catheter, Intravascular, Therapeutic, Short-Term Less Than 30 Days
Cleared on Sep 30, 2011 as substantially equivalent to K102520 (Becton Dickinson Infusion Therapy Systems, Inc., 2011) and 2 other predicates after a 137-day review. Its family tree reaches back 2 generations to 2004. 13 later devices descend from it.
- Decided
- Sep 30, 2011
- Review
- 137 days
- Class
- Class II
- Product code
- FOZ
- Recalls
- None
- Predicates
- 3
Its longest line of descent runs back 2 generations to K032843 (2004). 3 ancestors in all, the oldest K950301 (1995). 13 later devices descend from it, 1 citing it directly.
- Root · 2 generations backK032843 Nexiva Closed IV Catheter SystemBecton Dickinson Infusion Therapy Systems, Inc. · 2004 · Recalled
- 1 generation backK102520 BD Nexiva Closed IV Catheter SystemBecton Dickinson Infusion Therapy Systems, Inc. · 2011
- This deviceK111366 BD Nexiva Diffusics Closed IV Catheter SystemBecton, Dickinson and Company (BD) · 2011
- Descendant · cites it directly · 12 of its ownK123734 BD Nexiva Diffusics Closed IV Catheter SystemBecton Dickinson Infusion Therapy Systems, Inc. · 2013
- Descendant · 2 generations on · 11 of its ownK161777 BD Nexiva and BD Nexiva Diffusics Closed IV Catheter SystemsBecton Dickinson Infusion Therapy Systems, Inc. · 2016 · Recalled
- Descendant · 3 generations on · 6 of its ownK170336 BD Nexiva Closed IV Catheter System (Single Port) with MaxZero…Becton, Dickinson and Company · 2017
- Descendant · 3 generations on · 5 of its ownK183399 BD Nexiva Closed IV Catheter SystemBecton Dickinson Infusion Therapy Systems, Inc. · 2019 · Recalled
- Descendant · 3 generations on · 3 of its ownK170283 BD Nexiva Diffusics Closed IV Catheter SystemBecton, Dickinson and Company · 2017
Showing 5 of 13 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 13 · See all- K123734BD Nexiva Diffusics Closed IV Catheter SystemBecton Dickinson Infusion Therapy Systems, Inc. · 2013 · cites it directly12descendants
- K161777BD Nexiva and BD Nexiva Diffusics Closed IV Catheter SystemsBecton Dickinson Infusion Therapy Systems, Inc. · 2016 · 2 generations on11descendants
- K170336BD Nexiva Closed IV Catheter System (Single Port) with MaxZero Needleless ConnectorBecton, Dickinson and Company · 2017 · 3 generations on6descendants
- K183399BD Nexiva Closed IV Catheter SystemBecton Dickinson Infusion Therapy Systems, Inc. · 2019 · 3 generations on5descendants
- K170283BD Nexiva Diffusics Closed IV Catheter SystemBecton, Dickinson and Company · 2017 · 3 generations on3descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −2 | K032843 | Nexiva Closed IV Catheter System | Becton Dickinson Infusion Therapy Systems, Inc. | 2004 | 17 |
| −1 | K102520 | BD Nexiva Closed IV Catheter System | Becton Dickinson Infusion Therapy Systems, Inc. | 2011 | — |
| 0 (this device) | K111366 | BD Nexiva Diffusics Closed IV Catheter System | Becton, Dickinson and Company (BD) | 2011 | — |
| +1 | K123734 | BD Nexiva Diffusics Closed IV Catheter System | Becton Dickinson Infusion Therapy Systems, Inc. | 2013 | — |
| +2 | K161777 | BD Nexiva and BD Nexiva Diffusics Closed IV Catheter Systems | Becton Dickinson Infusion Therapy Systems, Inc. | 2016 | 1 |
| +3 | K170336 | BD Nexiva Closed IV Catheter System (Single Port) with MaxZero Needleless… | Becton, Dickinson and Company | 2017 | — |
| +3 | K183399 | BD Nexiva Closed IV Catheter System | Becton Dickinson Infusion Therapy Systems, Inc. | 2019 | 3 |
| +3 | K170283 | BD Nexiva Diffusics Closed IV Catheter System | Becton, Dickinson and Company | 2017 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1995 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2013 | 1 | 0 |
| 2016 | 1 | 0 |
| 2017 | 3 | 0 |
| 2019 | 1 | 0 |
| 2021 | 1 | 0 |
| 2023 | 2 | 0 |
| 2024 | 1 | 0 |
| 2025 | 2 | 0 |
| 2026 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in FOZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new FOZ device
- #1 K243403 BD Nexiva™ Closed IV Catheter Systemscore 14.8 · 8 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (3)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K102520 | BD Nexiva Closed IV Catheter SystemSummary page 1…Reference: 21 CFR 880.5200 - Class 11 Classification Panel: General Hospital Premarket Notification: Special 510(k) K102520, Traditional 510(k) K032843 Trade Name: BD Angiocath IV Cat… | 2011 |
| * | K032843 | Nexiva Closed IV Catheter SystemSummary page 1…ification Panel: General Hospital Premarket Notification: Special 510(k) K102520, Traditional 510(k) K032843 Trade Name: BD Angiocath IV Catheter with Sideholes Common Name: Periphe… | 2004 |
| * | K950301 | Angiocath (R) Nonvalon (R) and Angio-Set (R) IV CathetersSummary page 1…travascular Catheter CFR Reference: 880.5200 Classification Panel: General Hospital Premarket Notifications: K950301 (was a preamendment device before clearance under this 51 0(k) for a revised… | 1995 |
What descends from it? (13)
See all 131 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K123734 | BD Nexiva Diffusics Closed IV Catheter System | 2013 | 12 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 7 years and passes through 2 companies; a new generation was cleared every 6.9 years on median.
- 1 of the 3 ancestors has a recall of any class.
- Of its descendants, K123734 (Becton Dickinson Infusion Therapy Systems, Inc., 2013) has gone furthest, with 12 descendants of its own.
- 6 other devices also cite its predicate K102520.
How does its category compare?
All FOZ devicesFOZ Catheter, Intravascular, Therapeutic, Short-Term Less Than 30 Days: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.
FDA decisions per year · FOZ
11in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · FOZ
91in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · FOZ
4in 2023
Class I (5 since 2007) Class II/III not classified
Adverse event reports per year · FOZ
5,110in 2025
MAUDE reports naming product code FOZ, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 6 | 159 | 16 | 374 |
| 2008 | 9 | 103 | 0 | 422 |
| 2009 | 9 | 30 | 23 | 508 |
| 2010 | 3 | 28 | 115 | 370 |
| 2011 | 6 | 132 | 0 | 786 |
| 2012 | 13 | 122 | 0 | 560 |
| 2013 | 4 | 104 | 2 | 640 |
| 2014 | 9 | 99 | 4 | 815 |
| 2015 | 10 | 107 | 0 | 729 |
| 2016 | 9 | 63 | 3 (1) | 925 |
| 2017 | 9 | 51 | 22 | 1,966 |
| 2018 | 1 | — | 4 | 3,305 |
| 2019 | 8 | 140 | 3 | 4,365 |
| 2020 | 10 | 191 | 3 | 3,797 |
| 2021 | 4 | 242 | 1 | 4,674 |
| 2022 | 8 | 183 | 4 (2) | 4,133 |
| 2023 | 9 | 129 | 4 (2) | 4,430 |
| 2024 | 6 | 190 | 0 | 4,772 |
| 2025 | 11 | 91 | 0 | 5,110 |
| 2026 | 7 | 203 | 2 | — |
What is it indicated for?
The BD Nexiva™ Diffusics™ intravascular catheter is inserted into a patients vascular system to sample blood, monitor blood pressure or administer fluids. The BD Nexiva Diffusics catheters are suitable for use with power injectors when a direct connection is made.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K111366 · printed Nov 6, 2026
Cite this page
510(k) Report. “K111366: BD Nexiva Diffusics Closed IV Catheter System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K111366
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026