510(k) Report

510(k) · Cleared

Recalled · 2012

Rtvue Cam with Corneal Power Upgrade

K111505510(k) TraditionalCleared Sep 8, 2011100-day reviewClass II21 CFR 886.1570Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Optovue, Inc. · OBO Tomography, Optical Coherence

Cleared on Sep 8, 2011 as substantially equivalent to K071250 (Optovue, Inc., 2007) and 1 other predicate after a 100-day review. Its family tree reaches back 5 generations to 2002. 8 later devices descend from it. It has been recalled once.

Decided
Sep 8, 2011
Review
100 days
Class
Class II
Product code
OBO
Recalls
1
Predicates
2

Its longest line of descent runs back 5 generations to K012727 (2002). 11 ancestors in all, the oldest K955442 (1996). 8 later devices descend from it, 2 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2003: 1 other ancestor2006: 1 other ancestor2005: 1 other ancestor1999: 1 other ancestor1997: 1 other ancestor1996: 1 other ancestor2018: 1 descendant cleared2013: 1 descendant cleared2014: 1 descendant cleared2022: 2 descendants cleared2023: 1 descendant cleared2025: 1 descendant cleared2026: 1 descendant clearedReference device: K101505 · Rtvue Model Rtvue 100 · Optovue, Inc. · 2010 · recalledK012727 · Humphrey OCT3 · Carl Zeiss Ophthalmic Systems, Inc. · 2002K030433 · Stratusoct with RNFL Normative Database · Carl Zeiss Meditec, Inc. · 2003 · recalledK033123 · Stratusoct with RNFL & Macula Normative Database · Carl Zeiss Meditec, Inc. · 2004 · recalledK063343 · Bioptigen Spectral Domain Ophthalmic Imaging System · Bioptigen, Inc. · 2006K071250 · CA, Model: Cam · Optovue, Inc. · 20071995200020052010201520202025
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor2 generations back: 3 other ancestors3 generations back: 2 other ancestors 1 generation forward: 2 descendants2 generations forward: 4 descendants3 generations forward: 2 descendants K071250 · CA, Model: Cam · Optovue, Inc. · 2007K063343 · Bioptigen Spectral Domain Ophthalmic Imaging System · Bioptigen, Inc. · 2006K033123 · Stratusoct with RNFL & Macula Normative Database · Carl Zeiss Meditec, Inc. · 2004 · recalledK030433 · Stratusoct with RNFL Normative Database · Carl Zeiss Meditec, Inc. · 2003 · recalledK012727 · Humphrey OCT3 · Carl Zeiss Ophthalmic Systems, Inc. · 2002−50
  1. Root · 5 generations backK012727 Humphrey OCT3Carl Zeiss Ophthalmic Systems, Inc. · 2002
  2. 4 generations backK030433 Stratusoct with RNFL Normative DatabaseCarl Zeiss Meditec, Inc. · 2003 · Recalled
  3. 3 generations backK033123 Stratusoct with RNFL & Macula Normative DatabaseCarl Zeiss Meditec, Inc. · 2004 · Recalled
  4. 2 generations backK063343 Bioptigen Spectral Domain Ophthalmic Imaging SystemBioptigen, Inc. · 2006
  5. 1 generation backK071250 CA, Model: CamOptovue, Inc. · 2007
  6. This deviceK111505 Rtvue Cam with Corneal Power UpgradeOptovue, Inc. · 2011
  7. Descendant · cites it directly · 5 of its ownK180660 AvantiOptovue, Inc. · 2018
  8. Descendant · 2 generations on · 1 of its ownK222166 SOLIXOptovue, Inc. · 2022
  9. Descendant · 2 generations on · 1 of its ownK213265 Tomey Cornea/Anterior Segment OCT CASIA2Tomey Corporation · 2022
  10. Descendant · cites it directly · 1 of its ownK121622 Nidek RS-3000Nidek Co., Ltd. · 2013
  11. Descendant · 3 generations on · 0 of its ownK251848 Pentacam® Cornea OCTOculus Optikgeräte GmbH · 2026

Showing 5 of 8 descendants. See all descendants

Descendants cleared per year

2013: 12014: 12018: 12022: 22023: 12025: 12026: 1
2013high 2 (2022) · low 0 (2015)2026

Most influential descendants

Showing 5 of 8 · See all
  • K180660AvantiOptovue, Inc. · 2018 · cites it directly5descendants
  • K222166SOLIXOptovue, Inc. · 2022 · 2 generations on1descendant
  • K213265Tomey Cornea/Anterior Segment OCT CASIA2Tomey Corporation · 2022 · 2 generations on1descendant
  • K121622Nidek RS-3000Nidek Co., Ltd. · 2013 · cites it directly1descendant
  • K251848Pentacam® Cornea OCTOculus Optikgeräte GmbH · 2026 · 3 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K012727Humphrey OCT3Carl Zeiss Ophthalmic Systems, Inc.2002—
−4K030433Stratusoct with RNFL Normative DatabaseCarl Zeiss Meditec, Inc.20031
−3K033123Stratusoct with RNFL & Macula Normative DatabaseCarl Zeiss Meditec, Inc.20041
−2K063343Bioptigen Spectral Domain Ophthalmic Imaging SystemBioptigen, Inc.2006—
−1K071250CA, Model: CamOptovue, Inc.2007—
0 (this device)K111505Rtvue Cam with Corneal Power UpgradeOptovue, Inc.2011—
+1K180660AvantiOptovue, Inc.2018—
+2K222166SOLIXOptovue, Inc.2022—
+2K213265Tomey Cornea/Anterior Segment OCT CASIA2Tomey Corporation2022—
+1K121622Nidek RS-3000Nidek Co., Ltd.2013—
+3K251848Pentacam® Cornea OCTOculus Optikgeräte GmbH2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199610
199710
199910
200310
200510
200610

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201310
201410
201810
202220
202310
202510
202610
FIG. 1 — Lineage of K111505, 2002–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in OBO? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new OBO device

  1. #1 K250868 SPECTRALIS HRA+OCT and variantsscore 16.2 · 14 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K071250CA, Model: Cam
Summary page 2
…Page 1 of 4 opt~vue Optovue RTVue CAM with Corneal Power 51 0(K) Premarket Notification Predicate Devices (1) RTVue/CAM Module (K07 1250)-manufactured by Optovue, Inc. (2) Pentacam Scheimpflug Camera (K0307 19) - manufactured by Oculus Intended Use The CA…
Optovue, Inc.2007—
*K030719Pentacam Scheimpflug Camera
Summary page 2
…Corneal Power 51 0(K) Premarket Notification Predicate Devices (1) RTVue/CAM Module (K07 1250)-manufactured by Optovue, Inc. (2) Pentacam Scheimpflug Camera (K0307 19) - manufactured by Oculus Intended Use The CA, an auxiliary lens adapter, when used in conjunction with RTVue, is indicat…
Oculus Optikgerate GmbH20031
†K101505Rtvue Model Rtvue 100Optovue, Inc.20101

Also cleared against K071250: 4 other devices →

What descends from it? (8)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K180660AvantiOptovue, Inc.20185
K121622Nidek RS-3000Nidek Co., Ltd.20131

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Feb 21, 2012Not classifiedZ-1340-2012Employee errorA few doctors in the US were inadvertently sent the Cornea Power software version kit for international users instead of the domestic version.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 9 years and passes through 4 companies; a new generation was cleared every 1.2 years on median.
  • 3 of the 11 ancestors have a recall of any class.
  • Of its descendants, K180660 (Optovue, Inc., 2018) has gone furthest, with 5 descendants of its own.
  • 4 other devices also cite its predicate K071250.

How does its category compare?

All OBO devices

OBO Tomography, Optical Coherence: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.

FDA decisions per year · OBO

3in 2025

2007: 22008: 22009: 42010: 22011: 22012: 32013: 22014: 32015: 12016: 42017: 42018: 62019: 52020: 22021: 12022: 22023: 72024: 82025: 32026 (partial year): 2
2007high 8 (2024) · low 1 (2015)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · OBO

125in 2025

2009: 151 days median2012: 269 days median2014: 152 days median2016: 125 days median2017: 118 days median2018: 87 days median2019: 249 days median2023: 262 days median2024: 157 days median2025: 125 days median
2007high 269 (2012) · low 87 (2018)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · OBO

1in 2022

2010: 12011: 22012: 22018: 12021: 12022: 12026 (partial year): 1
2007high 2 (2011) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · OBO

4in 2025

2013: 22016: 12018: 12021: 12023: 32024: 32025: 4
2007high 4 (2025) · low 0 (2007)2025

MAUDE reports naming product code OBO, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—00
20082—00
2009415100
20102—10
20112—20
2012326920
20132—02
2014315200
20151—00
2016412501
2017411800
201868711
2019524900
20202—00
20211—11
20222—10
2023726203
2024815703
2025312504
20262—1—

What is it indicated for?

The CA, an auxiliary lens adapter, when used in conjunction with RTVue, is indicated for in vivo imaging and measurement of the cornea and other ocular structures of the anterior segment of the eye, including pachymetry and comneal power.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K111505: Rtvue Cam with Corneal Power Upgrade.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K111505

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026