510(k) Report

510(k) · Cleared

Cleared

Ergoselect/GE

K112121510(k) TraditionalCleared Oct 31, 2012464-day reviewClass II21 CFR 890.5360

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Ergoline GmbH · ISD Exerciser, Measuring

Cleared on Oct 31, 2012 as substantially equivalent to K053078 (Ergoline GmbH, 2006) after a 464-day review. Its family tree reaches back 2 generations to 1985.

Decided
Oct 31, 2012
Review
464 days
Class
Class II
Product code
ISD
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K851097 (1985). No later device cites it as a predicate yet.

  1. Root · 2 generations backK851097 Lode Model Corival ErgometerLode Corp. · 1985
  2. 1 generation backK053078 Ergoselect 100 K/P, Ergoselect 200 K/PErgoline GmbH · 2006
  3. This deviceK112121 Ergoselect/GEErgoline GmbH · 2012
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K851097Lode Model Corival ErgometerLode Corp.1985—
−1K053078Ergoselect 100 K/P, Ergoselect 200 K/PErgoline GmbH2006—
0 (this device)K112121Ergoselect/GEErgoline GmbH2012—
FIG. 1 — Lineage of K112121, 1985–2012Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in ISD? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K053078Ergoselect 100 K/P, Ergoselect 200 K/P
Summary page 1
…fication name: Measuring exerciser > 21 CER - 890.5360 Measuring exercise equipment Product Code: ISD Trade name: Ergoline Ergoselect / GE Predicate Device: K-number: K053078 Device name: Ergoselect 100 KIP; Ergoselect 200 K/P Firm: Ergoline GmbH Description of the Device: The Ergoselect is the resul…
Ergoline GmbH2006—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 27 years and passes through 2 companies; a new generation was cleared every 20.9 years on median.
  • None of the 2 ancestors has a recall.

How does its category compare?

All ISD devices

ISD Exerciser, Measuring: FDA decisions, review times, recalls and adverse event reports over 20 years. 2012, this device’s year, is highlighted.

FDA decisions per year · ISD

1in 2020

2008: 12012: 12015: 12019: 12020: 1
2007high 1 (2008) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · ISD

Too few ISD 510(k)s in any year since 2007 to give a median.

Recalls per year · ISD

1in 2013

2013: 1
2007high 1 (2013) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · ISD

2in 2025

2009: 12012: 12013: 12015: 12017: 12018: 22019: 12021: 12023: 42025: 2
2007high 4 (2023) · low 0 (2007)2025

MAUDE reports naming product code ISD, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20081—00
20090—01
20100—00
20110—00
20121—01
20130—11
20140—00
20151—01
20160—00
20170—01
20180—02
20191—01
20201—00
20210—01
20220—00
20230—04
20240—00
20250—02
20260—0—

What is it indicated for?

Physiotherapy in redevelopment of muscles for restoration of motion to joints or for use as an adjunct treatment for obesity.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K112121: Ergoselect/GE.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K112121

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026