510(k) · Cleared

Cleared

Wondfo Phencyclidine Urine Test, Tricyclic Antidepressants Urine Test

K112395510(k) TraditionalCleared Sep 9, 201121-day reviewClass II21 CFR 862.3910

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Guangzhou Wondfo Biotech Co., Ltd. · LFG Radioimmunoassay, Tricyclic Antidepressant Drugs

Cleared on Sep 9, 2011 as substantially equivalent to K020771 (ACON Laboratories, Inc., 2002) and 1 other predicate after a 21-day review. Its family tree reaches back 2 generations to 1998.

Decided
Sep 9, 2011
Review
21 days
Class
Class II
Product code
LFG
Recalls
None
Predicates
2

Its longest line of descent runs back 2 generations to K980249 (1998). 3 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 2 generations backK980249 Accusign Tca, Biosign Tca, Staus DS TcaPrinceton BioMeditech Corp. · 1998
  2. 1 generation backK021526 Acon Tca One Step Tricyclic Antidepressant Test Strip and DeviceACON Laboratories, Inc. · 2002
  3. This deviceK112395 Wondfo Phencyclidine Urine Test, Tricyclic Antidepressants Urine TestGuangzhou Wondfo Biotech Co., Ltd. · 2011
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K980249Accusign Tca, Biosign Tca, Staus DS TcaPrinceton BioMeditech Corp.1998—
−1K021526Acon Tca One Step Tricyclic Antidepressant Test Strip and DeviceACON Laboratories, Inc.2002—
0 (this device)K112395Wondfo Phencyclidine Urine Test, Tricyclic Antidepressants Urine TestGuangzhou Wondfo Biotech Co., Ltd.2011—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200210
FIG. 1 — Lineage of K112395, 1998–2011Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LFG? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K020771Acon One Step Drug Screen Test Card
Summary page 1
…CFR 862.3910 4. The legally marketed devices to which we are claiming equivalence [807.92(a)(3)): 1). Acon Laboratories, Inc., ACONS One Step Drug Screen Test, K020771. 2). Acon Laboratories, Inc., Acon® TCA One Step Tricyclic Antidepressant Test, K021526 5. Description of the device:…
ACON Laboratories, Inc.2002—
*K021526Acon Tca One Step Tricyclic Antidepressant Test Strip and Device
Summary page 1
…: 1). Acon Laboratories, Inc., ACONS One Step Drug Screen Test, K020771. 2). Acon Laboratories, Inc., Acon® TCA One Step Tricyclic Antidepressant Test, K021526 5. Description of the device: Assay Principle: lmmunochromatograph assay for Phencyclidine and Notriptyline Urine…
ACON Laboratories, Inc.2002—

Also cleared against K020771: 8 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 13 years and passes through 3 companies; a new generation was cleared every 9.1 years on median.
  • None of the 3 ancestors has a recall.
  • 8 other devices also cite its predicate K020771.

How does its category compare?

All LFG devices

LFG Radioimmunoassay, Tricyclic Antidepressant Drugs: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.

FDA decisions per year · LFG

1in 2015

2007: 12011: 12014: 12015: 1
2007high 1 (2007) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LFG

Too few LFG 510(k)s in any year since 2007 to give a median.

Recalls per year · LFG

1so far in 2026, the most since 2007

2026 (partial year): 1
2007high 1 (2026) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LFG

1in 2024

2012: 12017: 12020: 12024: 1
2007high 1 (2012) · low 0 (2007)2025

MAUDE reports naming product code LFG, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—00
20080—00
20090—00
20100—00
20111—00
20120—01
20130—00
20141—00
20151—00
20160—00
20170—01
20180—00
20190—00
20200—01
20210—00
20220—00
20230—00
20240—01
20250—00
20260—1—

What is it indicated for?

Wondfo Phencyclidine Urine Test is an immunochromatographic assay for the qualitative determination of Phencyclidine in human urine at a cutoff concentration of 2Sng/mL. The test is available in a dip card format and a cup format. It is intended for prescription use and over the counter use. The test provides only preliminary test results. A more specific alternative chemical method must be used in order to obtain a conformed analytical result. GCIMS is…

Read the full statement (237 words)

Wondfo Phencyclidine Urine Test is an immunochromatographic assay for the qualitative determination of Phencyclidine in human urine at a cutoff concentration of 2Sng/mL. The test is available in a dip card format and a cup format. It is intended for prescription use and over the counter use.

The test provides only preliminary test results. A more specific alternative chemical method must be used in order to obtain a conformed analytical result. GCIMS is the preferred confirmatory method. Clinical consideration and professional judgment should be exercised with any drug of abuse test result, particularly when the preliminary result is positive.

Wondfo Notriptyline Urine Test is an immunochromatographic assay for the qualitative determination of Notriptyline (major metabolite of Tricyclic Antidepressants) in human urine at a cutoff concentration of 1000 nglmL. The test is available in a dip card format and a cup format. It is intended for prescription use and over the counter use. The tests will yield preliminary positive results when the prescription drug Nortriptyline are ingested, even at or above therapeutic doses. There are no uniformly recognized drug levels for Nortriptyline in urine.

The test provides only preliminary test results. A more specific alternative chemical method must be used in order to obtain a conformed analytical result. GC/MS or HPLC is the preferred confirmatory method. Clinical consideration and professional judgment should be exercised with any drug of abuse test result, particularly when the preliminary result is positive.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K112395: Wondfo Phencyclidine Urine Test, Tricyclic Antidepressants Urine Test.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K112395

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026