510(k) Report

510(k) · Cleared

Cleared

Wondfo Cannabinoids Urine Test Wondfo Propoxyphene Urine Test

K121557510(k) TraditionalCleared Jul 25, 201261-day reviewClass II21 CFR 862.3870

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Guangzhou Wondfo Biotech Co., Ltd. · LDJ Enzyme Immunoassay, Cannabinoids

Cleared on Jul 25, 2012 as substantially equivalent to K020771 (ACON Laboratories, Inc., 2002) and 1 other predicate after a 61-day review. Its family tree reaches back 1 generation to 2002. 1 later device descends from it.

Decided
Jul 25, 2012
Review
61 days
Class
Class II
Product code
LDJ
Recalls
None
Predicates
2

Its longest line of descent runs back 1 generation to K020771 (2002). 2 ancestors in all. 1 later device descends from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2004: 1 other ancestor2015: 1 descendant clearedK020771 · Acon One Step Drug Screen Test Card · ACON Laboratories, Inc. · 2002200020052010201520202025
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor 1 generation forward: 1 descendant K020771 · Acon One Step Drug Screen Test Card · ACON Laboratories, Inc. · 20020
  1. Root · 1 generation backK020771 Acon One Step Drug Screen Test CardACON Laboratories, Inc. · 2002
  2. This deviceK121557 Wondfo Cannabinoids Urine Test Wondfo Propoxyphene Urine TestGuangzhou Wondfo Biotech Co., Ltd. · 2012
  3. Descendant · cites it directly · 0 of its ownK152495 Wondfo Propoxyphene Urine TestGuangzhou Wondfo Biotech Co., Ltd. · 2015

Most influential descendants

Showing 1 of 1 · See all
  • K152495Wondfo Propoxyphene Urine TestGuangzhou Wondfo Biotech Co., Ltd. · 2015 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K020771Acon One Step Drug Screen Test CardACON Laboratories, Inc.2002—
0 (this device)K121557Wondfo Cannabinoids Urine Test Wondfo Propoxyphene Urine TestGuangzhou Wondfo Biotech Co., Ltd.2012—
+1K152495Wondfo Propoxyphene Urine TestGuangzhou Wondfo Biotech Co., Ltd.2015—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200410

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201510
FIG. 1 — Lineage of K121557, 2002–2015Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LDJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LDJ device

  1. #1 K232732 Rapid Marijuana (THC) Test Strip 20, Rapid…score 9.4 · 10 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K020771Acon One Step Drug Screen Test Card
Summary page 1
…21 CFR 862.3700 4. The legally marketed device to which we are claiming equivalence [807.92(a)(3)]: 1. Acon Laboratories, Inc. ACON One Step Drug Screen Test, K020771. 2. Acon Laboratories, Inc. ACON One Step Propoxyphene Test Device and Test Strip, K040445 5. Description of the device…
ACON Laboratories, Inc.2002—
*K040445Acon PPX One Step Propoxyphene Test Strip and Acon PPX Step Propoxyphene Test Device
Summary page 1
…)]: 1. Acon Laboratories, Inc. ACON One Step Drug Screen Test, K020771. 2. Acon Laboratories, Inc. ACON One Step Propoxyphene Test Device and Test Strip, K040445 5. Description of the device: Assay Principle: lmmunochromatograph assay for Cannabinoids and Propoxyphene Urine Test…
ACON Laboratories, Inc.2004—

Also cleared against K020771: 8 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K152495Wondfo Propoxyphene Urine TestGuangzhou Wondfo Biotech Co., Ltd.20150

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • None of the 2 ancestors has a recall.
  • Of its descendants, K152495 (Guangzhou Wondfo Biotech Co., Ltd., 2015) has gone furthest, with 0 descendants of its own.
  • 8 other devices also cite its predicate K020771.

How does its category compare?

All LDJ devices

LDJ Enzyme Immunoassay, Cannabinoids: FDA decisions, review times, recalls and adverse event reports over 20 years. 2012, this device’s year, is highlighted.

FDA decisions per year · LDJ

2in 2024

2008: 22009: 12011: 42012: 42013: 32014: 22015: 32016: 12019: 12023: 12024: 2
2007high 4 (2011) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LDJ

48in 2015

2011: 219 days median2012: 193 days median2013: 162 days median2015: 48 days median
2007high 219 (2011) · low 48 (2015)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LDJ

1in 2023

2008: 42023: 1
2007high 4 (2008) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LDJ

1in 2015

2015: 1
2007high 1 (2015) · low 0 (2007)2025

MAUDE reports naming product code LDJ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20082—40
20091—00
20100—00
2011421900
2012419300
2013316200
20142—00
201534801
20161—00
20170—00
20180—00
20191—00
20200—00
20210—00
20220—00
20231—10
20242—00
20250—00
20260—0—

What is it indicated for?

Wondfo Propoxyphene Urine Test is an immunochromatogmaphic assay for the qualitative determination of d-Propoxyphene in human urine at a cutoff concentmation of 300 nglmL. The test is available in a dip card format and a cup format. This product is only intended for prescription use. The test provides only preliminary test results. A more specific alternative chemical method must be used in order to obtain a conformed analytical result. GCIMS is the…

Read the full statement (201 words)

Wondfo Propoxyphene Urine Test is an immunochromatogmaphic assay for the qualitative determination of d-Propoxyphene in human urine at a cutoff concentmation of 300 nglmL. The test is available in a dip card format and a cup format. This product is only intended for prescription use.

The test provides only preliminary test results. A more specific alternative chemical method must be used in order to obtain a conformed analytical result. GCIMS is the preferred confirmatory method. Clinical considemation and professional judgment should .be exercised with any drug of abuse test result, particularly when the preliminary result is positive.

Wondfo Cannabinoids Urine Test is an immunochromatographic assay for the qualitative determination of 11-nor-AS-THC-9-COOH (major metabolite of Cannabinoids) in human urine at a cutoff concentration of 50 nglrnL. The test is available in a dip card format and a cup format. It is intended for prescription use and over the counter use.

The test provides only preliminary test results. A more specific alternative chemical method must be used in order to obtain a conformed analytical result. GCIMS is the preferred confirmatory method. Clinical consideration and professional judgment should be exercised with any drug of abuse test result, particularly when the preliminary result is positive.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K121557: Wondfo Cannabinoids Urine Test Wondfo Propoxyphene Urine Test.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K121557

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026