510(k) Report

510(k) · Cleared

Recalled · Class II · 2017

AU5800(R) Chemistry Analyzer

K112412510(k) TraditionalCleared Dec 23, 2011123-day reviewClass II21 CFR 862.1600Recalls 7

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Beckman Coulter, Inc. · CEM Electrode, Ion Specific, Potassium

Cleared on Dec 23, 2011 as substantially equivalent to K002982 (Olympus America, Inc., 2000) after a 123-day review. Its family tree reaches back 1 generation to 2000. 3 later devices descend from it. It has been recalled 7 times.

Decided
Dec 23, 2011
Review
123 days
Class
Class II
Product code
CEM
Recalls
7
Predicates
1

Its longest line of descent runs back 1 generation to K002982 (2000). 3 later devices descend from it, 1 citing it directly.

Descendants, by year cleared 2016: 1 descendant cleared2019: 1 descendant cleared2023: 1 descendant clearedK002982 · Olympus AU2700 Clinical Chemistry Analyzer · Olympus America, Inc. · 2000200020052010201520202025
Descendants, by generation 1 generation forward: 1 descendant2 generations forward: 2 descendants K002982 · Olympus AU2700 Clinical Chemistry Analyzer · Olympus America, Inc. · 20000
  1. Root · 1 generation backK002982 Olympus AU2700 Clinical Chemistry AnalyzerOlympus America, Inc. · 2000
  2. This deviceK112412 AU5800(R) Chemistry AnalyzerBeckman Coulter, Inc. · 2011
  3. Descendant · cites it directly · 2 of its ownK161837 ISE Reagent, Glucose, CRP Latex, DxC 700 AU Clinical Chemistry…Beckman Coulter, Inc. · 2016
  4. Descendant · 2 generations on · 0 of its ownK220977 ISE Reagents, Glucose, CRP Latex, DxC 500 AU Clinical Chemistry…Beckman Coulter Laboratory Systems (Suzhou) Co., Ltd. · 2023 · Recalled
  5. Descendant · 2 generations on · 0 of its ownK183375 Yumizen C1200, Yumizen C1200 Glucose HK, Sodium Electrode, Potassium…Horiba, Ltd. · 2019

Most influential descendants

Showing 3 of 3 · See all
  • K161837ISE Reagent, Glucose, CRP Latex, DxC 700 AU Clinical Chemistry AnalyzerBeckman Coulter, Inc. · 2016 · cites it directly2descendants
  • K220977ISE Reagents, Glucose, CRP Latex, DxC 500 AU Clinical Chemistry AnalyzerBeckman Coulter Laboratory Systems (Suzhou) Co., Ltd. · 2023 · 2 generations on0descendants
  • K183375Yumizen C1200, Yumizen C1200 Glucose HK, Sodium Electrode, Potassium Electrode, Chloride…Horiba, Ltd. · 2019 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K002982Olympus AU2700 Clinical Chemistry AnalyzerOlympus America, Inc.2000—
0 (this device)K112412AU5800(R) Chemistry AnalyzerBeckman Coulter, Inc.2011—
+1K161837ISE Reagent, Glucose, CRP Latex, DxC 700 AU Clinical Chemistry AnalyzerBeckman Coulter, Inc.2016—
+2K220977ISE Reagents, Glucose, CRP Latex, DxC 500 AU Clinical Chemistry AnalyzerBeckman Coulter Laboratory Systems (Suzhou) Co., Ltd.20237
+2K183375Yumizen C1200, Yumizen C1200 Glucose HK, Sodium Electrode, Potassium…Horiba, Ltd.2019—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201610
201910
202310
FIG. 1 — Lineage of K112412, 2000–2023Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in CEM? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new CEM device

  1. #1 K253491 ISE indirect K for Gen.2; ISE indirect Na for…score 11.4 · 3 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K002982Olympus AU2700 Clinical Chemistry Analyzer
Summary page 1
…Candidate(s) ( Predicate Manufacturer Docume~nt K002982 AU5800 Clinical AU2700 Clinical Beckman Coulter, Chemistry Analyzer Chemistry…
Olympus America, Inc.2000—

What descends from it? (3)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K161837ISE Reagent, Glucose, CRP Latex, DxC 700 AU Clinical Chemistry AnalyzerBeckman Coulter, Inc.20162

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Feb 13, 2017Class IIZ-1704-2017Process controlBeckman Coulter is recalling the Rack ID Labels because the Rack ID number displayed and the Rack ID barcode label do not match.
Jul 30, 2015Class IIZ-2310-2016Nonconforming Material/ComponentBeckman coulter has received complaints regarding leaking and cracked C cups. When the cup cracks, coolant can leak onto the connectors of the Printed Circuit Boards (PCB) in the analyzer, resulting in a short-circuit causing the…
Sep 9, 2013Class IIZ-0153-2014Nonconforming Material/ComponentThe recall was initiated because Beckman Coulter has confirmed that some AU Clinical Chemistry Analyzer ISE units can experience premature ISE REF (Reference) valve failure. Premature valve failure can be detected by the presence of air…
Jun 3, 2013Class IIZ-1834-2013Software designThe recall was initiated because Beckman Coulter has identified a software error on AU5800 analyzers with the Automation Ready (AR) Sampler Kit. This software error results in the failure of the concentrated wash solution pump to stop…
Mar 20, 2013Class IIZ-1167-2013Software designBeckman Coulter, Inc. initiated this recall because there is a software error that has the potential to cause the reporting of erroneous patient results because of misidentification by the AU5800 system.
Nov 28, 2012Class IIZ-0913-2013Software designDue to a software data storage limitation which only occurs under certain conditions, measurements of the Reagent Blank (RB) or Calibration (CAL) sample results are not saved and the software reverts to a previously stored, acceptable…
Oct 26, 2012Class IIZ-1873-2013Software designBeckman Coulter is recalling the AU8500 Clinical Chemistry Analyzer because there is no labeling on the diluted detergent tank to show the proper disposition of the on/off valve.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • Of its descendants, K161837 (Beckman Coulter, Inc., 2016) has gone furthest, with 2 descendants of its own.

How does its category compare?

All CEM devices

CEM Electrode, Ion Specific, Potassium: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.

FDA decisions per year · CEM

1in 2025

2007: 12009: 12010: 32011: 32012: 42020: 12023: 22025: 12026 (partial year): 1
2007high 4 (2012) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · CEM

180in 2012

2010: 195 days median2011: 74 days median2012: 180 days median
2007high 195 (2010) · low 74 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · CEM

4in 2025

2008: 12010: 122011: 62016: 12019: 12020: 32021: 12023: 22025: 4
2007high 12 (2010) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · CEM

29in 2025

2007: 662008: 2452009: 792010: 1132011: 1262012: 452013: 372014: 42015: 72016: 62017: 322018: 132019: 252020: 272021: 182022: 162023: 302024: 422025: 29
2007high 245 (2008) · low 4 (2014)2025

MAUDE reports naming product code CEM, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—066
20080—1245
20091—079
2010319512113
20113746126
20124180045
20130—037
20140—04
20150—07
20160—16
20170—032
20180—013
20190—125
20201—327
20210—118
20220—016
20232—230
20240—042
20251—429
20261—0—

What is it indicated for?

The Beckman Coulter AU5800 Clinical Chemistry Analyzer is an automated chemistry analyzer that measures analytes such as Glucose, Magnesium, and Potassium in samples, in combination with appropriate reagents, calibrators, quality control (QC) material and other accessories. This system is for in vitro diagnostic use only. Applications include colorimetric, turbidimetric, latex agglutination, homogeneous enzyme immunoassay, and ion selective electrode.…

Read the full statement (199 words)

The Beckman Coulter AU5800 Clinical Chemistry Analyzer is an automated chemistry analyzer that measures analytes such as Glucose, Magnesium, and Potassium in samples, in combination with appropriate reagents, calibrators, quality control (QC) material and other accessories. This system is for in vitro diagnostic use only. Applications include colorimetric, turbidimetric, latex agglutination, homogeneous enzyme immunoassay, and ion selective electrode.

The Glucose test system is for the quantitative measurement of glucose in human serum, plasma, urine and cerebrospinal fluid on Beckman Coulter AU analyzers. Glucose measurements are used in the diagnosis and treatment of carbohydrate metabolism disorders including diabetes mellitus, neonatal hypoglycemnia, and idiopathic hypoglycemia, and of pancreatic islet cell carcinoma.

The Potassium test system is for the quantitative measurement of potassium in serum, plasma, and urine. Measurements obtained by this device are used to monitor electrolyte balance in the diagnosis and treatment of diseases conditions characterized by low or high blood potassium levels.

The Magnesium test system is for the quantitative measurement of Magnesium in human serum, plasma and urine on Beckman Coulter AU analyzers. Magnesium measurements are used in the diagnosis and treatment of hypomagnesemia (abnormally low plasma levels of magnesium) and hypermagnesemnia (abnormally high plasma levels of magnesium).

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K112412: AU5800(R) Chemistry Analyzer.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K112412

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026