510(k) Report

510(k) · Cleared

Cleared

Capillarys Hemoglobin, Capillarys Flex Piercing System

K112550510(k) TraditionalCleared May 25, 2012267-day reviewClass II21 CFR 864.7415

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Sebia · GKA Abnormal Hemoglobin Quantitation

Cleared on May 25, 2012 after a 267-day review. FDA’s file for it is a 510(k) statement, which names no predicate. 1 later device descends from it.

Decided
May 25, 2012
Review
267 days
Class
Class II
Product code
GKA
Recalls
None
Predicates
0

1 later device descends from it, 1 citing it directly.

Descendants, by year cleared 2018: 1 descendant cleared2010201520202025
  1. This deviceK112550 Capillarys Hemoglobin, Capillarys Flex Piercing SystemSebia · 2012
  2. Descendant · cites it directly · 0 of its ownK180762 Capi 3 Hemoglobin (E)Sebia · 2018

Most influential descendants

Showing 1 of 1 · See all
  • K180762Capi 3 Hemoglobin (E)Sebia · 2018 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K112550Capillarys Hemoglobin, Capillarys Flex Piercing SystemSebia2012—
+1K180762Capi 3 Hemoglobin (E)Sebia2018—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201810
FIG. 1 — Lineage of K112550, 2012–2018Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GKA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GKA device

  1. #1 K232027 CAPI 3 NEONAT Hb, CAPILLARYS 3 DBS Instrumentscore 7.1 · 1 generation · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K180762Capi 3 Hemoglobin (E)Sebia20180

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K180762 (Sebia, 2018) has gone furthest, with 0 descendants of its own.

How does its category compare?

All GKA devices

GKA Abnormal Hemoglobin Quantitation: FDA decisions, review times, recalls and adverse event reports over 20 years. 2012, this device’s year, is highlighted.

FDA decisions per year · GKA

1in 2024

2008: 12009: 12010: 12012: 22017: 12018: 12022: 12023: 12024: 1
2007high 2 (2012) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GKA

Too few GKA 510(k)s in any year since 2007 to give a median.

Recalls per year · GKA

1in 2020

2010: 22018: 52020: 1
2007high 5 (2018) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · GKA

2in 2013

2013: 2
2007high 2 (2013) · low 0 (2007)2025

MAUDE reports naming product code GKA, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20081—00
20091—00
20101—20
20110—00
20122—00
20130—02
20140—00
20150—00
20160—00
20171—00
20181—50
20190—00
20200—10
20210—00
20221—00
20231—00
20241—00
20250—00
20260—0—

What is it indicated for?

The CAPILLARYS HEMOGLOBIN(E) kit is designed for the separation of the normal hemoglobins (A, A2 and F) in human blood samples, and for the detection of the major hemoglobin variants (S, C, E and D), by capillary electrophoresis in alkaline buffer (pH 9.4) with the SEBIA CAPILLARYS 2 FLEX-PIERCING instrument. The CAPILLARYS HEMOGLOBIN(E) kit is designed for laboratory use. The CAPILLARYS 2 FLEX-PIERCING instrument is an automated analyzer which performs…

Read the full statement (120 words)

The CAPILLARYS HEMOGLOBIN(E) kit is designed for the separation of the normal hemoglobins (A, A2 and F) in human blood samples, and for the detection of the major hemoglobin variants (S, C, E and D), by capillary electrophoresis in alkaline buffer (pH 9.4) with the SEBIA CAPILLARYS 2 FLEX-PIERCING instrument. The CAPILLARYS HEMOGLOBIN(E) kit is designed for laboratory use.

The CAPILLARYS 2 FLEX-PIERCING instrument is an automated analyzer which performs a complete hemoglobin profile. for the quantitative analysis of the normal hemoglobin fractions A, A2 and F and for the detection of major hemoglobin variants S, C, E and D. The assay is performed on the hemolysate of whole blood samples collected in tubes containing K2EDTA or K3EDTA as anticoagulant.

Indications for use as stated in the FDA 510(k) statement.

Cite this page

510(k) Report. “K112550: Capillarys Hemoglobin, Capillarys Flex Piercing System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K112550

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026