510(k) Report

510(k) · Cleared

Cleared

CAPI 3 NEONAT Hb, CAPILLARYS 3 DBS Instrument

K232027510(k) TraditionalCleared Apr 4, 2024272-day reviewClass II21 CFR 864.7415

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Sebia · GKA Abnormal Hemoglobin Quantitation

Cleared on Apr 4, 2024 as substantially equivalent to K091283 (Sebia, 2010) after a 272-day review. Its family tree reaches back 1 generation to 2010.

Decided
Apr 4, 2024
Review
272 days
Class
Class II
Product code
GKA
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K091283 (2010). No later device cites it as a predicate yet.

K091283 · Capillarys Neonat HB (PN 2006) · Sebia · 20102010201520202025
K091283 · Capillarys Neonat HB (PN 2006) · Sebia · 20100
  1. Root · 1 generation backK091283 Capillarys Neonat HB (PN 2006)Sebia · 2010
  2. This deviceK232027 CAPI 3 NEONAT Hb, CAPILLARYS 3 DBS InstrumentSebia · 2024
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K091283Capillarys Neonat HB (PN 2006)Sebia2010—
0 (this device)K232027CAPI 3 NEONAT Hb, CAPILLARYS 3 DBS InstrumentSebia2024—
FIG. 1 — Lineage of K232027, 2010–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GKA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GKA device

  1. #1 K222635 Premier Resolution Systemscore 6.1 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K091283Capillarys Neonat HB (PN 2006)
Summary page 6
…redicate Device Name Regulation No. Vendor 510(k) number K091283 21 CFR Part 864.7415 – Abnormal CAPILLARYS NEONAT Hb Sebia…
Sebia2010—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.

How does its category compare?

All GKA devices

GKA Abnormal Hemoglobin Quantitation: FDA decisions, review times, recalls and adverse event reports over 20 years. 2024, this device’s year, is highlighted.

FDA decisions per year · GKA

1in 2024

2008: 12009: 12010: 12012: 22017: 12018: 12022: 12023: 12024: 1
2007high 2 (2012) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GKA

Too few GKA 510(k)s in any year since 2007 to give a median.

Recalls per year · GKA

1in 2020

2010: 22018: 52020: 1
2007high 5 (2018) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · GKA

2in 2013

2013: 2
2007high 2 (2013) · low 0 (2007)2025

MAUDE reports naming product code GKA, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20081—00
20091—00
20101—20
20110—00
20122—00
20130—02
20140—00
20150—00
20160—00
20171—00
20181—50
20190—00
20200—10
20210—00
20221—00
20231—00
20241—00
20250—00
20260—0—

What is it indicated for?

The CAPI 3 NEONAT Hb kit is intended as a qualitative screen for the detection of normal hemoglobins (F and A) and abnormal hemoglobins (S, C, E, D and Bart’s) in blood from human new-born collected on filter paper. This analysis is performed by capillary electrophoresis with the CAPILLARYS 3 DBS instrument. The CAPILLARYS 3 DBS instrument is a capillary electrophoresis based automated analyzer which performs a complete hemoglobin profile for the…

Read the full statement (145 words)

The CAPI 3 NEONAT Hb kit is intended as a qualitative screen for the detection of normal hemoglobins (F and A) and abnormal hemoglobins (S, C, E, D and Bart’s) in blood from human new-born collected on filter paper. This analysis is performed by capillary electrophoresis with the CAPILLARYS 3 DBS instrument.

The CAPILLARYS 3 DBS instrument is a capillary electrophoresis based automated analyzer which performs a complete hemoglobin profile for the qualitative analysis of hemoglobins (A, F, S, C, D, E and Bart’s). The assay is performed on the hemolysate of whole blood samples previously collected on filter paper.

The test result must be interpreted in conjunction with other biological and clinical findings. In case of abnormal hemoglobin presence, it should be confirmed by additional tests as per local recommendations. The device is intended for professional use only.

For In Vitro Diagnostic Use only.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K232027: CAPI 3 NEONAT Hb, CAPILLARYS 3 DBS Instrument.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K232027

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026