510(k) Report

510(k) · Cleared

Cleared

Asfora Bullet Cage

K112648510(k) SpecialCleared Mar 13, 2012183-day reviewClass II21 CFR 888.3080

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Medical Designs, LLC · MAX Intervertebral Fusion Device With Bone Graft, Lumbar

Cleared on Mar 13, 2012 as substantially equivalent to K090048 (Medical Designs, LLC, 2009) and 1 other predicate after a 183-day review. Its family tree reaches back 2 generations to 1996. 14 later devices descend from it.

Decided
Mar 13, 2012
Review
183 days
Class
Class II
Product code
MAX
Recalls
None
Predicates
2

Its longest line of descent runs back 2 generations to P950019 (1996). 3 ancestors in all. 14 later devices descend from it, 3 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2000: 1 other ancestor2018: 2 descendants cleared2021: 1 descendant cleared2022: 1 descendant cleared2023: 3 descendants cleared2025: 4 descendants cleared2024: 2 descendants cleared2026: 1 descendant clearedP950019 · Ray Threaded Fusion Cage (TFC)(TM) with Instrumentation · Stryker Spine · 1996 · recalledK090048 · Asfora Bullet Cage System · Medical Designs, LLC · 20091995200020052010201520202025
Other ancestors, by generationDescendants, by generation 2 generations back: 1 other ancestor 1 generation forward: 3 descendants2 generations forward: 2 descendants3 generations forward: 4 descendants4 generations forward: 5 descendants K090048 · Asfora Bullet Cage System · Medical Designs, LLC · 2009P950019 · Ray Threaded Fusion Cage (TFC)(TM) with Instrumentation · Stryker Spine · 1996 · recalled0
  1. Root · 2 generations backP950019 Ray Threaded Fusion Cage (TFC)(TM) with InstrumentationStryker Spine · 1996 · Recalled
  2. 1 generation backK090048 Asfora Bullet Cage SystemMedical Designs, LLC · 2009
  3. This deviceK112648 Asfora Bullet CageMedical Designs, LLC · 2012
  4. Descendant · cites it directly · 11 of its ownK211873 PSX Interbody SystemAlphatec Spine, Inc. · 2021
  5. Descendant · 2 generations on · 8 of its ownK222455 Calibrate LTX Interbody SystemAlphatec Spine, Inc. · 2022
  6. Descendant · 2 generations on · 7 of its ownK231438 Calibrate PSX Interbody System, Calibrate NanoTec PSX Interbody SystemAlphatec Spine, Inc. · 2023
  7. Descendant · 3 generations on · 7 of its ownK223611 Calibrate LTX Interbody SystemAlphatec Spine, Inc. · 2023
  8. Descendant · 3 generations on · 4 of its ownK242364 IdentiTi™ II Interbody SystemAlphatec Spine, Inc. · 2024

Showing 5 of 14 descendants. See all descendants

Descendants cleared per year

2018: 22021: 12022: 12023: 32024: 22025: 42026: 1
2018high 4 (2025) · low 0 (2019)2026

Most influential descendants

Showing 5 of 14 · See all
  • K211873PSX Interbody SystemAlphatec Spine, Inc. · 2021 · cites it directly11descendants
  • K222455Calibrate LTX Interbody SystemAlphatec Spine, Inc. · 2022 · 2 generations on8descendants
  • K231438Calibrate PSX Interbody System, Calibrate NanoTec PSX Interbody SystemAlphatec Spine, Inc. · 2023 · 2 generations on7descendants
  • K223611Calibrate LTX Interbody SystemAlphatec Spine, Inc. · 2023 · 3 generations on7descendants
  • K242364IdentiTi™ II Interbody SystemAlphatec Spine, Inc. · 2024 · 3 generations on4descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2P950019Ray Threaded Fusion Cage (TFC)(TM) with InstrumentationStryker Spine19961
−1K090048Asfora Bullet Cage SystemMedical Designs, LLC2009—
0 (this device)K112648Asfora Bullet CageMedical Designs, LLC2012—
+1K211873PSX Interbody SystemAlphatec Spine, Inc.2021—
+2K222455Calibrate LTX Interbody SystemAlphatec Spine, Inc.2022—
+2K231438Calibrate PSX Interbody System, Calibrate NanoTec PSX Interbody SystemAlphatec Spine, Inc.2023—
+3K223611Calibrate LTX Interbody SystemAlphatec Spine, Inc.2023—
+3K242364IdentiTi™ II Interbody SystemAlphatec Spine, Inc.2024—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200010

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201820
202110
202210
202330
202420
202540
202610
FIG. 1 — Lineage of K112648, 1996–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MAX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MAX device

  1. #1 K203714 NuVasive Thoracolumbar Interbody Systems…score 102.5 · 24 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K090048Asfora Bullet Cage System
Summary page 1
…cation: Class 11 Intervertebral Body Fusion Device 21 CFR 888.3080 Product Code: MAX Predicate Device(s): The subject device is equivalent to the following devices: o K090048, Asfora Bullet Cage System e P950019/S9 Ray TFC Threaded Fusion Cage (down-classified to Class II) Device Description: The Asf…
Medical Designs, LLC2009—
*P950019Ray Threaded Fusion Cage (TFC)(TM) with Instrumentation
Summary page 1
…Fusion Device 21 CFR 888.3080 Product Code: MAX Predicate Device(s): The subject device is equivalent to the following devices: o K090048, Asfora Bullet Cage System e P950019/S9 Ray TFC Threaded Fusion Cage (down-classified to Class II) Device Description: The Asfora Bullet Cage (ABC) is a threaded ti…
Stryker Spine19961

Also cleared against K090048: 3 other devices →

What descends from it? (14)

See all 14

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K211873PSX Interbody SystemAlphatec Spine, Inc.202111
K181625Life Spine Resolute™ Threaded Cage SystemLife Spine, Inc.20180
K181591Fixated Asfora BULLET CAGE® (FABC)Medical Designs, LLC20180

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 16 years and passes through 2 companies; a new generation was cleared every 12.8 years on median.
  • 1 of the 3 ancestors has a recall of any class.
  • Of its descendants, K211873 (Alphatec Spine, Inc., 2021) has gone furthest, with 11 descendants of its own.
  • 3 other devices also cite its predicate K090048.

How does its category compare?

All MAX devices

MAX Intervertebral Fusion Device With Bone Graft, Lumbar: FDA decisions, review times, recalls and adverse event reports over 20 years. 2012, this device’s year, is highlighted.

FDA decisions per year · MAX

29in 2025

2007: 72008: 352009: 312010: 292011: 492012: 482013: 582014: 582015: 532016: 642017: 762018: 642019: 602020: 562021: 532022: 412023: 302024: 382025: 292026 (partial year): 18
2007high 76 (2017) · low 7 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MAX

85in 2025

2007: 86 days median2008: 88 days median2009: 102 days median2010: 137 days median2011: 98 days median2012: 69 days median2013: 102 days median2014: 115 days median2015: 113 days median2016: 124 days median2017: 116 days median2018: 114 days median2019: 131 days median2020: 106 days median2021: 109 days median2022: 95 days median2023: 87 days median2024: 91 days median2025: 85 days median2026 (partial year): 95 days median
2007high 137 (2010) · low 69 (2012)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MAX

5in 2025

2008: 22009: 92011: 32012: 11, 1 Class I2014: 32015: 12016: 62017: 12018: 42019: 12022: 12024: 12025: 5
2007high 11 (2012) · low 0 (2007)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · MAX

811in 2025

2007: 122008: 192009: 902010: 1542011: 2012012: 3272013: 3802014: 3662015: 5242016: 6472017: 5962018: 6162019: 6992020: 6402021: 6222022: 6182023: 5762024: 7292025: 811
2007high 811 (2025) · low 12 (2007)2025

MAUDE reports naming product code MAX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007786012
20083588219
200931102990
2010291370154
201149983201
2012486911 (1)327
2013581020380
2014581153366
2015531131524
2016641246647
2017761161596
2018641144616
2019601311699
2020561060640
2021531090622
202241951618
202330870576
202438911729
202529855811
202618950—

What is it indicated for?

The Asfora Bullet Cage is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC…

Read the full statement (118 words)

The Asfora Bullet Cage is indicated for spinal fusion procedures in skeletally mature patients with degenerative disc disease (DDD) and instability in the lumbar spine at one or two contiguous levels from L2 to S1. DDD for lumbar systems is defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies. The DDD patients may also have up to Grade I spondylolisthesis at the involved level(s). The ABC cage devices are used with autogenous bone graft. Patients should be skeletally mature and have had at least six (6) months of non-operative treatment prior to implant. When implanted via a posterior (PLIF, TLIF) approach, this device should be used with supplemental fixation.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K112648: Asfora Bullet Cage.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K112648

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026