Statim 2000 G4 Cassette

K112872510(k) SpecialCleared Jul 10, 2012284-day reviewClass II21 CFR 880.6880

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Scican, Ltd. · FLE Sterilizer, Steam

Cleared on Jul 10, 2012 after a 284-day review. FDA’s file for it is a 510(k) statement, which names no predicate.

Decided
Jul 10, 2012
Review
284 days
Class
Class II
Product code
FLE
Recalls
None
Predicates
0

FDA’s file for it is a 510(k) statement, which names no predicate.

FIG. 1 — Lineage of K112872Source: FDA 510(k) database · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FLE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FLE device

  1. #1 K250168 Life Ultra 25L Tabletop Mono Chamber Steam…score 12.7 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

How does its category compare?

All FLE devices

FLE Sterilizer, Steam: FDA decisions, review times, recalls and adverse event reports over 20 years. 2012, this device’s year, is highlighted.

FDA decisions per year · FLE

4in 2025

2007: 52008: 12009: 82010: 22011: 52012: 52013: 52014: 22015: 32016: 12017: 32018: 82019: 52020: 22021: 52022: 102023: 72024: 22025: 42026 (partial year): 3
2007high 10 (2022) · low 1 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FLE

184in 2025

2007: 67 days median2009: 109 days median2011: 141 days median2012: 111 days median2013: 241 days median2015: 302 days median2017: 233 days median2018: 146 days median2019: 192 days median2021: 147 days median2022: 133 days median2023: 88 days median2025: 184 days median2026 (partial year): 85 days median
2007high 302 (2015) · low 67 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FLE

1in 2021

2007: 12008: 12011: 12012: 12013: 22015: 12018: 12019: 22021: 12026 (partial year): 1
2007high 2 (2013) · low 0 (2009)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FLE

71in 2025

2007: 192008: 212009: 192010: 202011: 632012: 692013: 1122014: 1132015: 682016: 762017: 632018: 902019: 912020: 872021: 812022: 702023: 662024: 642025: 71
2007high 113 (2014) · low 19 (2007)2025

MAUDE reports naming product code FLE, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007567119
20081—121
20098109019
20102—020
20115141163
20125111169
201352412112
20142—0113
20153302168
20161—076
20173233063
20188146190
20195192291
20202—087
20215147181
202210133070
2023788066
20242—064
20254184071
20263851—

What is it indicated for?

The STATIM 2000/5000 G4 Cassette Autoclaves are steam flush pressure pulse dynamic air removal steam autoclaves designed for the reprocessing of reusable medical and dental instruments to achieve successful sterilization in a clinical setting. They utilize saturated steam at high pressures in order to attain an effective kill of infectious bic-organisms. The units are intended to sterilize heat and moisture stable medical and dental instruments…

Read the full statement (612 words)

The STATIM 2000/5000 G4 Cassette Autoclaves are steam flush pressure pulse dynamic air removal steam autoclaves designed for the reprocessing of reusable medical and dental instruments to achieve successful sterilization in a clinical setting. They utilize saturated steam at high pressures in order to attain an effective kill of infectious bic-organisms.

The units are intended to sterilize heat and moisture stable medical and dental instruments (including handpieces) which are commonly found in medical and dental 0ffices, 0hospitals, clinics, and other facilities. The instruments must be suitable for steam sterilization at 134 C (275 F) or 121 C (250 F). The STATIM 2000/5000 G4 Cassette Autoclaves are only intended for heat stable instruments.

The sterilization cycles as to established times, temperatures and indicated uses for the STATIM 2000 G4 Cassette Autoclave are as follows:

CYCLE: UNWRAPPED (for Immediate Use); TEMPERATURE: 1350 C (275-F); STERILIZATION / DRYING TIME: 3.5 min. / 60 min.; MAX LOAD: 1.0 kg (2.2 Ibs); ITEMS: Solid metal instruments, hinged metal instruments, dental and phaco handpieces, with drying.

CYCLE: WRAPPED; TEMPERATURE: 1350 C (275-F); STERILIZATION / DRYING TIME: 10 min. / 60 min.; MAX LOAD: 1.0 kg (2.2 Ibs); ITEMS: Solid, hollow (including dental and phaco handpieces) & hinged metal instruments wrapped in paper/paper or paper/plastic pouches that are cleared by FDA for the claimed cycles, with drying.

CYCLE: RUBBER & PLASTICS; TEMPERATURE: 1210 C (250 0 F); STERILIZATION / DRYING TIME: 15 min. / 60 min.; MAX LOAD: 0.4 kg (0.9 Ibs); ITEMS: Instruments of rubber & plastic construction (exceptions are listed in the Operator's Manual) with drying.

The lumen specifications are as follows:

Dental Handpieces: 7 handpieces within a 1 kg load

Phaco Handpieces: 2 handpieces, 2 lumens per handpiece, where the lumens have a minimum inner diameter of 1.5 mm (0.06") and a maximum length of 150 mm (6") or a minimum inner diameter of 2 mm (0.08") and maximum length of 190 mm (7.5")

The sterilization cycles as to established times, temperatures and indicated uses for the STATIM 5000 G4 Cassette Autoclave are as follows:

CYCLE: UNWRAPPED (for Immediate Use); TEMPERATURE: 132 0C (2700 F); STERILIZATION / DRYING TIME: 3.5 min. / 60 min.; MAX LOAD: 0.5 kg (1.1 Ibs); ITEMS: Solid metal instruments, hinged metal instruments with drying.

CYCLE: WRAPPED; TEMPERATURE: 1320C (270 0F); STERILIZATION / DRYING TIME: 6 min. / 60 min.; MAX LOAD: 1.5 kg (3.3 Ibs); ITEMS: Solid, hollow (including dental and phaco handpieces) & hinged metal instruments wrapped in paper/paper or paper/plastic pouches that are cleared by FDA for the claimed cycles, with drying.

CYCLE: RUBBER & PLASTICS; TEMPERATURE: 12100 (2500 F); STERILIZATION / DRYING TIME: 35 min. / 60 min.; MAX LOAD: 0.4 kg (0.9 Ibs); ITEMS: Instruments of rubber & plastic construction (exceptions are listed in the Operators Manual) with drying.

CYCLE: HEAVY DUTY UNWRAPPED (for Immediate Use); TEMPERATURE: 1320C (270 0 F); STERILIZATION / DRYING TIME: 6 min. / 60 min.; MAX LOAD: 1.5 kg (3.3 Ibs); ITEMS: Solid metal instruments, hinged metal instruments and dental and phaco handpieces with drying. The extended cassette must be used for the processing of longer instruments such as autoclavable rigid endoscopes in this cycle.

The lumen specifications are as follows:

Dental Handpieces: 8 handpieces within a 1.5 kg load

Phaco Handpieces: 5 handpieces, 2 lumens per handpiece, where the lumens have a minimum inner diameter of 1.5 mm (0.06") and a maximum length of 150 mm (6") or a minimum inner diameter of 2 mm (0.08') and maximum length of 190 mm (7.5")

Rigid Endoscopes: 3 scopes, 1 lumen per scope, where the lumens have a minimum inner diameter of 1 mm (0.04') and a maximum length of 490 mm (19")

Indications for use as stated in the FDA 510(k) statement.

Cite this page

510(k) Report. “K112872: Statim 2000 G4 Cassette.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K112872

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Page last updated Nov 3, 2026