510(k) · Cleared
ClearedSteritec Containers System & Meditray Products
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Case Medical, Inc. · FRG Wrap, Sterilization
Cleared on Jan 24, 2012 as substantially equivalent to K090068 (Case Medical, Inc., 2010) after a 112-day review. Its family tree reaches back 2 generations to 2008. 1 later device descends from it.
- Decided
- Jan 24, 2012
- Review
- 112 days
- Class
- Class II
- Product code
- FRG
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 2 generations to K080558 (2008). 1 later device descends from it, 1 citing it directly.
- Root · 2 generations backK080558 Steritite Container System & Meditray ProductsCase Medical, Inc. · 2008 · Recalled
- 1 generation backK090068 Steritite Universal Container System and Meditray ProductsCase Medical, Inc. · 2010
- This deviceK112904 Steritec Containers System & Meditray ProductsCase Medical, Inc. · 2012
- Descendant · cites it directly · 0 of its ownK161415 SteriTite Containers System & MediTray ProductsCase Medical, Inc. · 2017
Most influential descendants
Showing 1 of 1 · See all- K161415SteriTite Containers System & MediTray ProductsCase Medical, Inc. · 2017 · cites it directly0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −2 | K080558 | Steritite Container System & Meditray Products | Case Medical, Inc. | 2008 | 1 |
| −1 | K090068 | Steritite Universal Container System and Meditray Products | Case Medical, Inc. | 2010 | — |
| 0 (this device) | K112904 | Steritec Containers System & Meditray Products | Case Medical, Inc. | 2012 | — |
| +1 | K161415 | SteriTite Containers System & MediTray Products | Case Medical, Inc. | 2017 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2017 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in FRG? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new FRG device
- #1 K234050 HALYARD® ONE-STEP® Sterilization Wrap…score 15.8 · 7 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K090068 | Steritite Universal Container System and Meditray ProductsSummary page 1…equivalent to: *SteriTite®V universal container system -anodized- previously cleared for Anisco V-PRO I Lumen cycle, 510(K) #K090068. 5.2 Description of the Device: The SteriTite universal container system consists of a family of rigid reusable co… | 2010 |
What descends from it? (1)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K161415 | SteriTite Containers System & MediTray Products | 2017 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 4 years and passes through 1 company; a new generation was cleared every 1.9 years on median.
- 1 of the 2 ancestors has a recall of any class.
- Of its descendants, K161415 (Case Medical, Inc., 2017) has gone furthest, with 0 descendants of its own.
- 1 other device also cites its predicate K090068.
How does its category compare?
All FRG devicesFRG Wrap, Sterilization: FDA decisions, review times, recalls and adverse event reports over 20 years. 2012, this device’s year, is highlighted.
FDA decisions per year · FRG
9in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · FRG
151in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · FRG
2in 2022
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · FRG
18in 2025
MAUDE reports naming product code FRG, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 3 | 182 | 0 | 1 |
| 2008 | 2 | — | 0 | 2 |
| 2009 | 4 | 171 | 0 | 2 |
| 2010 | 4 | 213 | 0 | 0 |
| 2011 | 6 | 110 | 0 | 12 |
| 2012 | 10 | 133 | 0 | 4 |
| 2013 | 6 | 146 | 2 | 5 |
| 2014 | 8 | 177 | 0 | 13 |
| 2015 | 12 | 196 | 0 | 9 |
| 2016 | 9 | 131 | 0 | 20 |
| 2017 | 9 | 260 | 29 | 7 |
| 2018 | 5 | 150 | 0 | 22 |
| 2019 | 9 | 258 | 0 | 10 |
| 2020 | 5 | 122 | 14 | 21 |
| 2021 | 4 | 170 | 0 | 9 |
| 2022 | 9 | 217 | 2 | 4 |
| 2023 | 9 | 230 | 0 | 13 |
| 2024 | 11 | 182 | 0 | 21 |
| 2025 | 9 | 151 | 0 | 18 |
| 2026 | 4 | 247 | 0 | — |
What is it indicated for?
The SteriTite Universal Container System, with MediTray products, is a reusable sterilization container system used to enclose other medical devices, which are to be sterilized, transported and stored by a health-care provider. The container consists of a perforated base and lid, with filter retention plates, and disposable polypropylene filters. The SteriTite container system is compatible for use with AMSCO V-PRO 1 Plus low temperature Sterilization…
Read the full statement (640 words)
The SteriTite Universal Container System, with MediTray products, is a reusable sterilization container system used to enclose other medical devices, which are to be sterilized, transported and stored by a health-care provider. The container consists of a perforated base and lid, with filter retention plates, and disposable polypropylene filters. The SteriTite container system is compatible for use with AMSCO V-PRO 1 Plus low temperature Sterilization System, Lumen and Non-lumen Cycle, and AMSCO V-PRO maX low temperature Sterilization System Lumen, Non-lumen and Flexible Cycle. The SteriTite container has been validated with stainless steel and porous lumens, inoculated product, insert boxes, multilevel tray systems and various inserts, including brackets, posts and partitions. The SteriTite container may be used for sterilization of medical devices, including full instrument sets and mixed loads.
* 30 days of real time shelf-life testing with handling events has been conducted for SteriTite containers after sterilization in Amsco V-PRO sterilization lumen cycle.
* Reuse testing: Material Compatibility was assessed after 100 cycles of AMSCO V-PRO 1 lumen cycles.
SteriTite Universal Container System is recommended for use in:
1. V-PRO 1 Plus sterilizer in:
* Non-lumen cycles to sterilize non-lumened instruments, including non-lumened rigid endoscopes and non-lumened hinged instruments, such as forceps or scissors.
* Lumen cycles to sterilize instruments with diffusion restricted areas, such as the hinged portion of forceps and scissors, and medical devices, including rigid endoscopes, with a single stainless steel lumen, with an inside diameter of 3mm or larger and a length of 400mm or shorter for a maximum of 20 lumens per load.
2. V-PRO maX sterilizer in:
* Non-lumen cycles to sterilize non-lumened instruments including non-lumened rigid endoscopes and non-lumened hinged instruments, such as forceps or scissors.
* Lumen cycles to sterilize instruments with diffusion restricted areas, such as the hinged portion of forceps and scissors, and medical devices, including rigid endoscopes with a single stainless steel lumen with an inside diameter of 3mm or larger, and a length of 400mm or shorter for a maximum of 20 lumens per load.
* Flexible cycles to sterilize single or dual lumen surgical flexible endoscopes in either of two load configurations (per sterilizer manufacturer instruction):
a. Two flexible endoscopes and no additional load, each having either:
* a single lumen with an inside diameter of 1mm or larger, and a length of 1050mm or shorter, or
* two lumens, with one having an inside diameter of 1mm or larger and a length of 998mm or shorter, and the second one an inside diameter of 1mm or larger and a length of 850mm or shorter.
b. One flexible endoscope and load, each having either:
* a single lumen with an inside diameter of 1mm or larger and a length of 1050mm or shorter, or
* two lumens with one having an inside diameter of 1mm or larger and a length of 998mm or shorter and the second one an inside diameter of 1mm or larger and a length of 850mm or shorter.
The SteriTite Universal Container System is recommended to be used for the sterilization of surfaces and rigid or flexible lumens:
Table 1: SteriTite Universal Container System in AMSCO V-PRO sterilization.
Sterilizer | Cycle | Rigid lumens 3mm dia. or larger and 400 mm long or shorter | Flexible lumens 1mm dia. or larger and 1050mm long or shorter | Surfaces
Amsco V-PRO 1 Plus | Lumen cycle | X | |
Amsco V-PRO 1 Plus | Non-lumen cycle | | | X
Amsco V-PRO Max | Lumen cycle | X | |
Amsco V-PRO Max | Non-lumen cycle | | | X
Amsco V-PRO Max | Flexible cycle | | X |
Note:
Lumen cycle parameters are the same for both sterilizer models referred to in the current submission.
Non-Lumen cycle parameters are the same for both sterilizer models referred to in the current submission.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K112904 · printed Nov 5, 2026
Cite this page
510(k) Report. “K112904: Steritec Containers System & Meditray Products.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K112904
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026