ClearedHALYARD* ONE-STEP* Sterilization Wrap; HALYARD* QUICK CHECK* Sterilization Wrap; HALYARD* SEQUENTIAL Sterilization Wrap; HALYARD* SMART-FOLD* Sterilization Wrap
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
O&M Halyard, Inc. · FRG Wrap, Sterilization
Cleared on May 18, 2026 as substantially equivalent to K234050 (O&M Halyard, Inc., 2024) after a 227-day review. Its family tree reaches back 8 generations to 1988.
- Decided
- May 18, 2026
- Review
- 227 days
- Class
- Class II
- Product code
- FRG
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 8 generations to K881471 (1988). 9 ancestors in all. No later device cites it as a predicate yet.
- Root · 8 generations backK881471 Kimguard (Regular & Heavy Duty) Sterile WrapKimberly-Clark Corp. · 1988 · Recalled
- 7 generations backK082177 Kimguard One-Step Sterilization WrapKimberly-Clark Corp. · 2009
- 6 generations backK091685 Kimguard One-Step Sterilization Wrap, Models KC100, KC200, KC300…Kimberly-Clark Corp. · 2009
- 5 generations backK112805 Kimguard One-Step Sterilization WrapKimberly-Clark Corp. · 2012
- 4 generations backK141712 Kimguard One Step Sterilization WrapHalyard Health · 2014
- 3 generations backK192147 Halyard ONE-STEP* Sterilization WrapOwens & Minor (O&M) Halyard, Inc. · 2019
- 2 generations backK214007 HALYARD ONE-STEP Sterilization Wrap, HALYARD QUICK CHECK…Owens & Minor (O&M) Halyard, Inc. · 2022
- 1 generation backK234050 HALYARD® ONE-STEP® Sterilization Wrap, HALYARD® QUICK CHECK®…O&M Halyard, Inc. · 2024
- This deviceK253454 HALYARD* ONE-STEP* Sterilization Wrap; HALYARD* QUICK CHECK*…O&M Halyard, Inc. · 2026
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −8 | K881471 | Kimguard (Regular & Heavy Duty) Sterile Wrap | Kimberly-Clark Corp. | 1988 | 1 |
| −7 | K082177 | Kimguard One-Step Sterilization Wrap | Kimberly-Clark Corp. | 2009 | — |
| −6 | K091685 | Kimguard One-Step Sterilization Wrap, Models KC100, KC200, KC300, KC400, KC… | Kimberly-Clark Corp. | 2009 | — |
| −5 | K112805 | Kimguard One-Step Sterilization Wrap | Kimberly-Clark Corp. | 2012 | — |
| −4 | K141712 | Kimguard One Step Sterilization Wrap | Halyard Health | 2014 | — |
| −3 | K192147 | Halyard ONE-STEP* Sterilization Wrap | Owens & Minor (O&M) Halyard, Inc. | 2019 | — |
| −2 | K214007 | HALYARD ONE-STEP Sterilization Wrap, HALYARD QUICK CHECK Sterilization Wrap | Owens & Minor (O&M) Halyard, Inc. | 2022 | — |
| −1 | K234050 | HALYARD® ONE-STEP® Sterilization Wrap, HALYARD® QUICK CHECK® Sterilization… | O&M Halyard, Inc. | 2024 | — |
| 0 (this device) | K253454 | HALYARD* ONE-STEP* Sterilization Wrap; HALYARD* QUICK CHECK* Sterilization… | O&M Halyard, Inc. | 2026 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2009 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in FRG? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new FRG device
- #1 K234050 HALYARD® ONE-STEP® Sterilization Wrap…score 15.8 · 7 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K234050 | HALYARD® ONE-STEP® Sterilization Wrap, HALYARD® QUICK CHECK® Sterilization Wrap…Summary page 17…T-FOLD* Sterilization Wrap Common Name: Sterilization Wrap Classification Name: Sterilization wrap (21 CFR 880.6850, Product Code FRG) Predicate Device: K234050 (HALYARD® ONE-STEP® Sterilization Wrap, HALYARD® QUICK CHECK® Sterilization Wrap, HALYARD® SEQUENTIAL Ster… | 2024 |
| † | K240330 | HALYARD* SMART-FOLD* Sterilization Wrap (H450); HALYARD* SMART-FOLD* Sterilization Wrap… | 2024 |
| † | K214007 | HALYARD ONE-STEP Sterilization Wrap, HALYARD QUICK CHECK Sterilization Wrap | 2022 |
| † | K192147 | Halyard ONE-STEP* Sterilization Wrap | 2019 |
| † | K181959 | HALYARD SMART-FOLD* Sterilization Wrap (H450, H650) | 2019 |
| † | K143053 | KIMGUARD ONE-STEP Sterilization Wrap | 2015 |
| † | K142782 | KIMGUARD ONE-STEP Sterilization Wrap | 2015 |
| † | K141712 | Kimguard One Step Sterilization Wrap | 2014 |
| † | K140963 | Kimguard Smart-Fold Sterilization Wrap | 2014 |
| † | K141612 | Kimguard One-Step Sterilization Wrap | 2014 |
| † | K141071 | Kimguard One-Step Sterilization Wrap | 2014 |
| † | K113806 | Kimguard One Step Sterilization Wrap | 2013 |
| † | K112805 | Kimguard One-Step Sterilization Wrap | 2012 |
| † | K112300 | Kimguard Smart-Fold* Sterilization Wrap | 2012 |
| † | K092167 | Kimguard One-Step Sterilization Wrap, Models KC100, KC200, KC300, KC400, KC500, KC600 | 2009 |
| † | K091685 | Kimguard One-Step Sterilization Wrap, Models KC100, KC200, KC300, KC400, KC 500, KC600 | 2009 |
| † | K082177 | Kimguard One-Step Sterilization Wrap | 2009 |
| † | K172191 | STERIZONE VP4 Sterilizer | 2018 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 38 years and passes through 4 companies; a new generation was cleared every 2.8 years on median.
- 1 of the 9 ancestors has a recall of any class.
- 1 other device also cites its predicate K234050.
How does its category compare?
All FRG devicesFRG Wrap, Sterilization: FDA decisions, review times, recalls and adverse event reports over 20 years. 2026, this device’s year, is highlighted.
FDA decisions per year · FRG
9in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · FRG
151in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · FRG
2in 2022
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · FRG
18in 2025
MAUDE reports naming product code FRG, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 3 | 182 | 0 | 1 |
| 2008 | 2 | — | 0 | 2 |
| 2009 | 4 | 171 | 0 | 2 |
| 2010 | 4 | 213 | 0 | 0 |
| 2011 | 6 | 110 | 0 | 12 |
| 2012 | 10 | 133 | 0 | 4 |
| 2013 | 6 | 146 | 2 | 5 |
| 2014 | 8 | 177 | 0 | 13 |
| 2015 | 12 | 196 | 0 | 9 |
| 2016 | 9 | 131 | 0 | 20 |
| 2017 | 9 | 260 | 29 | 7 |
| 2018 | 5 | 150 | 0 | 22 |
| 2019 | 9 | 258 | 0 | 10 |
| 2020 | 5 | 122 | 14 | 21 |
| 2021 | 4 | 170 | 0 | 9 |
| 2022 | 9 | 217 | 2 | 4 |
| 2023 | 9 | 230 | 0 | 13 |
| 2024 | 11 | 182 | 0 | 21 |
| 2025 | 9 | 151 | 0 | 18 |
| 2026 | 4 | 247 | 0 | — |
What is it indicated for?
Indication for Use (QUICK CHECK, ONE-STEP and SEQUENTIAL): HALYARD ONE-STEP, QUICK CHECK and SEQUENTIAL Sterilization Wraps are intended to enclose another medical device that is to be sterilized by a healthcare provider using: • Pre-vacuum steam at 270°F/132°C for 4 minutes. The wrap was validated for dry times of 20 minutes for Models 100 and 200, and for 30 minutes for Models 300, 400, 500, and 600. • 100% ethylene oxide (EO) with a concentration of…
Read the full statement (480 words)
Indication for Use (QUICK CHECK, ONE-STEP and SEQUENTIAL):
HALYARD ONE-STEP, QUICK CHECK and SEQUENTIAL Sterilization Wraps are intended to
enclose another medical device that is to be sterilized by a healthcare provider using:
• Pre-vacuum steam at 270°F/132°C for 4 minutes. The wrap was validated for dry times of 20 minutes
for Models 100 and 200, and for 30 minutes for Models 300, 400, 500, and 600.
• 100% ethylene oxide (EO) with a concentration of 725-735 mg/L at 131°F/55°C and 40%-80% relative
humidity for 60 minutes. The wrap was validated for aeration times for EO sterilization of 8 hours at
55°C or 12 hours at 43.3°C.
• STERIS V-PRO® Low Temperature Sterilization Systems. The wrap was validated to be effectively
aerated during the pre-programmed cycles.
• STERIS V-PRO® 60 (Lumen, Non-Lumen and Flexible Cycles)
• STERIS V-PRO® s2 (Lumen, Non-Lumen and Flexible Cycles)
• STERIS V-PRO® 1 (Lumen Cycle)
• STERIS V-PRO® 1 Plus (Lumen and Non-Lumen Cycles)
• STERIS V-PRO® maX (Lumen, Non-Lumen and Flexible Cycles)
• STERIS V-PRO® maX 2 (Lumen, Non-Lumen and Flexible Cycles)
• Gravity steam at 250°F/121°C for 30 minutes (25 minute dry time for Models 100, 200 and 300 and 30
minute dry time for Models 400, 500, and 600)
• Advanced Sterilization Products STERRAD® Sterilization System
• STERRAD® 50, 100S, and 200
• STERRAD® NX®, (Standard Cycle, Advanced Cycle)
• STERRAD® NX® with ALLClear® Technology, (Standard Cycle, Advanced Cycle)
• STERRAD® 100NX® (Standard Cycle, Flex Cycle, EXPRESS Cycle, DUO Cycle)
• STERRAD® 100NX® with ALLClear® Technology, (Standard Cycle, Flex Cycle, EXPRESS Cycle,
DUO Cycle)
• STERILUCENT® HC80TT Sterilization Cycles (Lumen and Flexible Cycles)
• Stryker Sterizone® VP4 Sterilizer Cycle 1
Indication For Use (SMART-FOLD):
HALYARD® SMART-FOLD Sterilization Wraps are intended to be used to enclose another medical
device that is to be sterilized by a healthcare provider using:
- Pre-vacuum steam at 270°F/132°C for 4 minutes. The wrap was validated for dry times of 30 minutes.
- 100% ethylene oxide (EO) with a concentration of 725-735 mg/L at 131°F/55°C and 40%-80% relative
humidity for 60 minutes. The wrap was validated for aeration times for EO sterilization of 8 hours at
131°F/55°C or 12 hours at 110°F/43.3°C.
STERIS V-PRO® Low Temperature Sterilization Systems.
• STERIS® V-PRO® 60 (Lumen, Non-Lumen and Flexible Cycles)
• STERIS® V-PRO® s2 (Lumen, Non-Lumen and Flexible Cycles)
• STERIS® V-PRO® 1 (Lumen Cycle)
• STERIS® V-PRO® 1 Plus (Lumen and Non-Lumen Cycle)
• STERIS® V-PRO® maX (Lumen, Non-Lumen and Flexible Cycle)
• STERIS® V-PRO® maX 2 (Lumen, Non-Lumen and Flexible Cycle)
- Advanced Sterilization Products STERRAD® Sterilization System
• STERRAD® 100S
• STERRAD® NX®, (Standard Cycle, Advanced Cycle)
• STERRAD® NX® with ALLClear® Technology, (Standard Cycle, Advanced Cycle)
• STERRAD® 100NX® (Standard Cycle, Flex Cycle, EXPRESS Cycle, DUO Cycle, ULTRA GI
Cycle)
• STERRAD® 100NX® with ALLClear® Technology, (Standard Cycle, Flex Cycle, EXPRESS Cycle,
DUO Cycle, ULTRA GI Cycle)
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K253454 · printed Nov 4, 2026
Cite this page
510(k) Report. “K253454: HALYARD* ONE-STEP* Sterilization Wrap; HALYARD* QUICK CHECK* Sterilization Wrap; HALYARD* SEQUENTIAL Sterilization Wrap; HALYARD* SMART-FOLD* Sterilization Wrap.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K253454
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded Oct 30, 2026
- Summary read Oct 30, 2026 (extraction version 2d9447fa9ea4)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026