Dimension Clinical Chemistry System

K112999510(k) SpecialCleared Nov 22, 201146-day reviewClass I21 CFR 862.2160Recalls 7

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Siemens Healthcare Diagnostics · JJE Analyzer, Chemistry (Photometric, Discrete), For Clinical Use

Cleared on Nov 22, 2011 as substantially equivalent to K963498 (Dade Chemistry Systems, Inc., 1997) after a 46-day review. Its family tree reaches back 1 generation to 1997. It has been recalled 7 times.

Decided
Nov 22, 2011
Review
46 days
Class
Class I
Product code
JJE
Recalls
7
Predicates
1

Its longest line of descent runs back 1 generation to K963498 (1997). No later device cites it as a predicate yet.

K963498 · Ferr Flex Reagent Cartridge · Dade Chemistry Systems, Inc. · 1997 · recalled1995200020052010
  1. Root · 1 generation backK963498 Ferr Flex Reagent CartridgeDade Chemistry Systems, Inc. · 1997 · Recalled
  2. This deviceK112999 Dimension Clinical Chemistry SystemSiemens Healthcare Diagnostics · 2011
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K963498Ferr Flex Reagent CartridgeDade Chemistry Systems, Inc.19973
0 (this device)K112999Dimension Clinical Chemistry SystemSiemens Healthcare Diagnostics2011—
FIG. 1 — Lineage of K112999, 1997–2011Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JJE? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K963498Ferr Flex Reagent Cartridge
Summary page 1
…roduct Product Device 51 ~~ Class _______Code Dirrension®RxL/RxL DimensionS RxL/RxL Max K963498 1 862.2160 JJB Max clinical chemistry clinical chemistry analyzer analyzer…
Dade Chemistry Systems, Inc.19973

Also cleared against K963498: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Sep 28, 2018Class IIZ-0409-2019Device DesignThermal chamber motors have electrical cables with single insulation rather than the required double insulation. There is no exposed current due to the single insulation that could result in a potential electrical shock
Jun 29, 2017Class IIZ-1651-2018Device DesignVarious assays used to measure different chemical levels in blood, urine, or cerebrospinal fluid may interfere with the drugs sulfasalazine and/or sulfapyridine causing falsely elevated or falsely depressed results.
Nov 10, 2015Class IIZ-0460-2016Nonconforming Material/ComponentSiemens has identified RMS refrigeration compressors that are missing the safety cover on the electrical termination block. The exposed electrical hazard on the electrical termination block is located directly behind the RMS Waste…
Nov 10, 2015Class IIZ-0461-2016Nonconforming Material/ComponentSiemens has identified RMS refrigeration compressors that are missing the safety cover on the electrical termination block. The exposed electrical hazard on the electrical termination block is located directly behind the RMS Waste…
Apr 2, 2015Class IIZ-1615-2015Under Investigation by firmCertain Dimension Integrated Chemistry Systems Instrument Power Configurations may have been installed with a non-standard instrument power plug.The use of a non-standard plug configuration as described may lead to a potential electrical…
May 27, 2014Class IIIZ-2133-2014Employee errorThere is a misassembly issue with the photometer installed on Dimension¿ Integrated Chemistry Systems instruments. Through internal investigation by Siemens Healthcare Diagnostics has confirmed that a limited number of Dimension…
Jul 17, 2012Class IIZ-2182-2012Device DesignSiemens Healthcare Diagnostics has confirmed that partial insertion of the power cord on the Dimension Reagent Management System (RMS) power input module can cause the plug to overheat and potentially create a fire hazard. RMS without a…

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has a recall.
  • 1 other device also cites its predicate K963498.

How does its category compare?

All JJE devices

JJE Analyzer, Chemistry (Photometric, Discrete), For Clinical Use: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.

FDA decisions per year · JJE

1in 2019

2008: 12011: 22012: 12013: 12014: 32019: 1
2007high 3 (2014) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JJE

224in 2014

2014: 224 days median
2007high 224 (2014)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JJE

6in 2025

2007: 202008: 202009: 142010: 322011: 252012: 162013: 212014: 142015: 152016: 92017: 182018: 172019: 72020: 72021: 62023: 122024: 62025: 62026 (partial year): 5
2007high 32 (2010) · low 0 (2022)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JJE

4,400in 2025

2007: 2,1812008: 2,1592009: 3,4402010: 3,2732011: 11,6062012: 3,7072013: 2,4892014: 2,8412015: 2,7932016: 2,5802017: 1,8692018: 4,5902019: 3,9482020: 3,9862021: 3,9202022: 3,9982023: 3,7832024: 4,2212025: 4,400
2007high 11,606 (2011) · low 1,869 (2017)2025

MAUDE reports naming product code JJE, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—202,181
20081—202,159
20090—143,440
20100—323,273
20112—2511,606
20121—163,707
20131—212,489
20143224142,841
20150—152,793
20160—92,580
20170—181,869
20180—174,590
20191—73,948
20200—73,986
20210—63,920
20220—03,998
20230—123,783
20240—64,221
20250—64,400
20260—5—

What is it indicated for?

Sodium measurements are used for monitoring electrolyte imbalances. Potassium measurements are used for diagnosis in diseases with high and low Potassium levels. Chloride measurements are primarily use to detect and treatment of metabolic disorders. Glucose measurements are used in the diagnosis and treatment of carbohydrate metabolism disorders including diabetes mellitus, neonatal hypoglycemia, and idiopathic hypoglycemia, and of pancreatic islet cell…

Read the full statement (153 words)

Sodium measurements are used for monitoring electrolyte imbalances.

Potassium measurements are used for diagnosis in diseases with high and low Potassium levels.

Chloride measurements are primarily use to detect and treatment of metabolic disorders.

Glucose measurements are used in the diagnosis and treatment of carbohydrate metabolism disorders including diabetes mellitus, neonatal hypoglycemia, and idiopathic hypoglycemia, and of pancreatic islet cell carcinoma.

Thyroid stimulating hormone measurements are used in diagnosis of thyroid or pituitary disorders.

Aspartate aminotransferase measurements are used in the diagnosis and treatment of certain types of liver and heart disease.

The Dimension ® clinical chemistry system is an in vitro diagnostic device intended to duplicate manual analytical procedures by performing automatically various steps such as pipetting, mixing, heating, and measuring spectral intensities to determine a variety of analytes in human body fluids.

The Dimension system chemical and immunochemical applications utilize photometric, turbidimetric, and integrated ion selective multisensor technology for clinical use.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K112999: Dimension Clinical Chemistry System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K112999

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.