510(k) · Cleared
ClearedSpartan S3 Facet System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Amendia, Inc. · MRW System, Facet Screw Spinal Device
Cleared on Dec 6, 2011 as substantially equivalent to K092568 (Amendia, Inc., 2009) and 5 other predicates after a 56-day review. Its family tree reaches back 4 generations to 1997.
- Decided
- Dec 6, 2011
- Review
- 56 days
- Class
- Class U
- Product code
- MRW
- Recalls
- None
- Predicates
- 6
Its longest line of descent runs back 4 generations to K953076 (1997). 11 ancestors in all. No later device cites it as a predicate yet.
- Root · 4 generations backK953076 Townley Facet/Pedicular Screw Plating SystemSofamor Danek USA,Inc. · 1997
- 3 generations backK051856 TRANS1 Facet ScrewsTrans1 Incorporated · 2005
- 2 generations backK073515 TRANS1 Facet ScrewTrans1 Incorporated · 2008
- 1 generation backK092568 Spartan S3 Facet SystemAmendia, Inc. · 2009
- This deviceK113011 Spartan S3 Facet SystemAmendia, Inc. · 2011
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −4 | K953076 | Townley Facet/Pedicular Screw Plating System | Sofamor Danek USA,Inc. | 1997 | — |
| −3 | K051856 | TRANS1 Facet Screws | Trans1 Incorporated | 2005 | — |
| −2 | K073515 | TRANS1 Facet Screw | Trans1 Incorporated | 2008 | — |
| −1 | K092568 | Spartan S3 Facet System | Amendia, Inc. | 2009 | — |
| 0 (this device) | K113011 | Spartan S3 Facet System | Amendia, Inc. | 2011 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2000 | 1 | 0 |
| 2001 | 2 | 0 |
| 2002 | 1 | 0 |
| 2003 | 1 | 0 |
| 2009 | 1 | 0 |
| 2010 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in MRW? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new MRW device
- #1 K230840 PMT Facet Fixation System, Lumbar (PMT FFS-LX)score 26.0 · 6 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (6)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K092568 | Spartan S3 Facet SystemSummary page 1…ns for use are the same for both systems. Predicate Device(s): The predicate devices previously cleared by FDA are the previously cleared Spartan S3 Facet Screw System (K092568), the Lanx Concero Facet Screw System (KIOI 364), DISCOVERY Facet Screw (K012773), Triad Facet Screw System (K02041 1), Oasys Bon… | 2009 |
| * | K101364 | Lanx Facet Screw System | 2010 |
| * | K012773 | Discovery Facet Screw Fixation SystemSummary page 1…ices previously cleared by FDA are the previously cleared Spartan S3 Facet Screw System (K092568), the Lanx Concero Facet Screw System (KIOI 364), DISCOVERY Facet Screw (K012773), Triad Facet Screw System (K02041 1), Oasys Bone Screw (K03 1657) and the Transi Facet Screw (K0735 15). Performance Testing: T… | 2001 |
| * | K020411 | Nuvasive Triad Facet Screw SystemSummary page 1…he previously cleared Spartan S3 Facet Screw System (K092568), the Lanx Concero Facet Screw System (KIOI 364), DISCOVERY Facet Screw (K012773), Triad Facet Screw System (K02041 1), Oasys Bone Screw (K03 1657) and the Transi Facet Screw (K0735 15). Performance Testing: The pre-clinical testing was performed… | 2002 |
| * | K031657 | Stryker Spine Oasys Bone ScrewSummary page 1…S3 Facet Screw System (K092568), the Lanx Concero Facet Screw System (KIOI 364), DISCOVERY Facet Screw (K012773), Triad Facet Screw System (K02041 1), Oasys Bone Screw (K03 1657) and the Transi Facet Screw (K0735 15). Performance Testing: The pre-clinical testing was performed following ASTM F2 193-02. Te… | 2003 |
| * | K073515 | TRANS1 Facet ScrewSummary page 1…Lanx Concero Facet Screw System (KIOI 364), DISCOVERY Facet Screw (K012773), Triad Facet Screw System (K02041 1), Oasys Bone Screw (K03 1657) and the Transi Facet Screw (K0735 15). Performance Testing: The pre-clinical testing was performed following ASTM F2 193-02. Testing consisted of static and dynamic… | 2008 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 14 years and passes through 3 companies; a new generation was cleared every 2.5 years on median.
- None of the 11 ancestors has a recall.
- 3 other devices also cite its predicate K092568.
How does its category compare?
All MRW devicesMRW System, Facet Screw Spinal Device: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.
FDA decisions per year · MRW
7in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · MRW
97in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · MRW
3in 2011
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · MRW
3in 2025
MAUDE reports naming product code MRW, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 1 |
| 2008 | 3 | 88 | 0 | 0 |
| 2009 | 6 | 89 | 0 | 2 |
| 2010 | 6 | 108 | 0 | 7 |
| 2011 | 3 | 122 | 3 | 62 |
| 2012 | 4 | 119 | 0 | 6 |
| 2013 | 7 | 110 | 0 | 4 |
| 2014 | 0 | — | 0 | 1 |
| 2015 | 2 | — | 0 | 2 |
| 2016 | 2 | — | 0 | 1 |
| 2017 | 1 | — | 0 | 4 |
| 2018 | 2 | — | 0 | 4 |
| 2019 | 3 | 90 | 0 | 0 |
| 2020 | 0 | — | 0 | 0 |
| 2021 | 0 | — | 0 | 1 |
| 2022 | 3 | 252 | 0 | 0 |
| 2023 | 3 | 190 | 0 | 1 |
| 2024 | 7 | 50 | 0 | 2 |
| 2025 | 7 | 97 | 0 | 3 |
| 2026 | 5 | 169 | 0 | — |
What is it indicated for?
The Spartan S3 Facet System is indicated for the posterior surgical treatment of any or all of the following at the C2 to SI (inclusive) spinal levels: 1) Trauma, including spinal fractures and/or dislocations; 2) Spondylolisthesis; 3) Pseudoarthrosis or failed previous fusions which are symptomatic or which may cause secondary instability or deformity; 4) Degenerative diseases which include: (a) degenerative disc disease (DDD) as defined by neck and/or…
Read the full statement (112 words)
The Spartan S3 Facet System is indicated for the posterior surgical treatment of any or all of the following at the C2 to SI (inclusive) spinal levels:
1) Trauma, including spinal fractures and/or dislocations;
2) Spondylolisthesis;
3) Pseudoarthrosis or failed previous fusions which are symptomatic or which may cause secondary instability or deformity;
4) Degenerative diseases which include: (a) degenerative disc disease (DDD) as defined by neck and/or back pain of discogenic origin as confirmed by patient history with degeneration of the disc as confirmed by radiographic studies and/or (b) degenerative disease of the facets with instability.
The Spartan S3 Facet System will provide temporary stabilization as an adjunct to spinal fusion.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K113011 · printed Nov 6, 2026
Cite this page
510(k) Report. “K113011: Spartan S3 Facet System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K113011
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026