510(k) · Cleared
Recalled · Class II · 2012Synthes Mirs
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Synthes Spine · NKB Thoracolumbosacral Pedicle Screw System
Cleared on Dec 21, 2011 as substantially equivalent to K963045 (Synthes (Usa), 1997) and 13 other predicates after a 70-day review. Its family tree reaches back 7 generations to 1995. 1 of the 169 devices in its family, counting itself, has a Class I recall. 93 later devices descend from it. It has been recalled 3 times.
- Decided
- Dec 21, 2011
- Review
- 70 days
- Class
- Class II
- Product code
- NKB
- Recalls
- 3
- Predicates
- 14
Its longest line of descent runs back 7 generations to K950697 (1995). 75 ancestors in all, the oldest K781443 (1978). 93 later devices descend from it, 3 citing it directly. 1 of the 169 devices in this family, counting this one, has a Class I recall.
- Root · 7 generations backK950697 Depuy Motech Moss Miami Spinal System - Pedicle FixationDepuy Motech · 1995
- 6 generations backK050461 Xia 4.5 Spinal SystemStryker Spine · 2005
- 5 generations backK052761 Modification to: Xia 4.5 Spinal SystemStryker Spine · 2005
- 4 generations backK060361 Xia Spinal System, Xia 4.5 Spinal SystemStryker Spine · 2006 · Recalled
- 3 generations backK060979 Xia Titanium and 4.5 Spinal SystemsStryker Spine · 2006
- 2 generations backK082942 Modfication to: Expedium Spine SystemDepuy Spine, Inc. · 2008
- 1 generation backK090648 Viper 2 SystemDepuy Spine, Inc. · 2009
- This deviceK113044 Synthes MirsSynthes Spine · 2011
- Descendant · cites it directly · 74 of its ownK120571 Synthes Uss ConnectorSynthes Spine · 2012
- Descendant · 2 generations on · 67 of its ownK133746 Polaris Spinal SystemBiomet Spine (Aka Ebi, LLC) · 2014 · Recalled
- Descendant · 3 generations on · 30 of its ownK143248 Reform Pedicle Screw SystemPrecision Spine, Inc. · 2014
- Descendant · 4 generations on · 26 of its ownK150856 Reform Pedicle Screw SystemPrecision Spine, Inc. · 2015
- Descendant · 5 generations on · 21 of its ownK173130 Reform® Midline Cortical Screw SystemPrecision Spine, Inc. · 2017
Showing 5 of 93 descendants. See all descendants
Descendants cleared per year
Class I recalls in this family
- K100952 Modification to Synthes Matrix Systemdirect predicate · 2010
Most influential descendants
Showing 5 of 93 · See all- K120571Synthes Uss ConnectorSynthes Spine · 2012 · cites it directly74descendants
- K133746Polaris Spinal SystemBiomet Spine (Aka Ebi, LLC) · 2014 · 2 generations on67descendants
- K143248Reform Pedicle Screw SystemPrecision Spine, Inc. · 2014 · 3 generations on30descendants
- K150856Reform Pedicle Screw SystemPrecision Spine, Inc. · 2015 · 4 generations on26descendants
- K173130Reform® Midline Cortical Screw SystemPrecision Spine, Inc. · 2017 · 5 generations on21descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −7 | K950697 | Depuy Motech Moss Miami Spinal System - Pedicle Fixation | Depuy Motech | 1995 | — |
| −6 | K050461 | Xia 4.5 Spinal System | Stryker Spine | 2005 | — |
| −5 | K052761 | Modification to: Xia 4.5 Spinal System | Stryker Spine | 2005 | — |
| −4 | K060361 | Xia Spinal System, Xia 4.5 Spinal System | Stryker Spine | 2006 | 1 |
| −3 | K060979 | Xia Titanium and 4.5 Spinal Systems | Stryker Spine | 2006 | — |
| −2 | K082942 | Modfication to: Expedium Spine System | Depuy Spine, Inc. | 2008 | — |
| −1 | K090648 | Viper 2 System | Depuy Spine, Inc. | 2009 | — |
| 0 (this device) | K113044 | Synthes Mirs | Synthes Spine | 2011 | — |
| +1 | K120571 | Synthes Uss Connector | Synthes Spine | 2012 | — |
| +2 | K133746 | Polaris Spinal System | Biomet Spine (Aka Ebi, LLC) | 2014 | 1 |
| +3 | K143248 | Reform Pedicle Screw System | Precision Spine, Inc. | 2014 | — |
| +4 | K150856 | Reform Pedicle Screw System | Precision Spine, Inc. | 2015 | — |
| +5 | K173130 | Reform® Midline Cortical Screw System | Precision Spine, Inc. | 2017 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1978 | 1 | 0 |
| 1993 | 1 | 0 |
| 1994 | 1 | 0 |
| 1995 | 1 | 0 |
| 1996 | 3 | 0 |
| 1997 | 3 | 0 |
| 1998 | 2 | 0 |
| 1999 | 2 | 0 |
| 2000 | 6 | 0 |
| 2001 | 6 | 0 |
| 2002 | 4 | 0 |
| 2003 | 8 | 0 |
| 2004 | 6 | 0 |
| 2005 | 4 | 0 |
| 2006 | 2 | 0 |
| 2007 | 5 | 0 |
| 2008 | 5 | 0 |
| 2009 | 2 | 0 |
| 2010 | 4 | 1 |
| 2011 | 2 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2012 | 4 | 0 |
| 2014 | 3 | 0 |
| 2015 | 5 | 0 |
| 2016 | 3 | 0 |
| 2017 | 12 | 0 |
| 2018 | 4 | 0 |
| 2019 | 5 | 0 |
| 2020 | 6 | 0 |
| 2021 | 7 | 0 |
| 2022 | 6 | 0 |
| 2023 | 9 | 0 |
| 2024 | 12 | 0 |
| 2025 | 9 | 0 |
| 2026 | 8 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new NKB device
- #1 K223494 CD Horizon Spinal Systemscore 40.4 · 30 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (14)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K963045 | Synthes (U.S.a.) Universal Sacral SystemSummary page 1…Orthopaedic and Rehabilitation Devices Panel Product Code: NKB, MNH, MNI, KWQ, KWP Predicates: Synthes UISS, K963045 DePuy Viper 2, K090648 Synthes Click'X, K992739 Abbott Spine Pathfin… | 1997 |
| * | K090648 | Viper 2 SystemSummary page 1…abilitation Devices Panel Product Code: NKB, MNH, MNI, KWQ, KWP Predicates: Synthes UISS, K963045 DePuy Viper 2, K090648 Synthes Click'X, K992739 Abbott Spine Pathfinder, K030625 Synthe… | 2009 |
| * | K992739 | Click'xSummary page 1…Product Code: NKB, MNH, MNI, KWQ, KWP Predicates: Synthes UISS, K963045 DePuy Viper 2, K090648 Synthes Click'X, K992739 Abbott Spine Pathfinder, K030625 Synthes Click'X, K031 175 Abbott Spine… | 2000 |
| * | K030625 | Spinal Concepts Inc. PathfinderSummary page 1…: Synthes UISS, K963045 DePuy Viper 2, K090648 Synthes Click'X, K992739 Abbott Spine Pathfinder, K030625 Synthes Click'X, K031 175 Abbott Spine Pathfinder, K071 174 Synth… | 2003 |
| * | K031175 | Click'x Monoaxial Screws and HooksSummary page 1…DePuy Viper 2, K090648 Synthes Click'X, K992739 Abbott Spine Pathfinder, K030625 Synthes Click'X, K031 175 Abbott Spine Pathfinder, K071 174 Synthes UISS Illiosacral and Polyaxial, DePuy Expedium,… | 2003 |
| * | K071174 | Pathfinder System Polyaxial Pedicle ScrewsSummary page 1…Synthes Click'X, K992739 Abbott Spine Pathfinder, K030625 Synthes Click'X, K031 175 Abbott Spine Pathfinder, K071 174 Synthes UISS Illiosacral and Polyaxial, DePuy Expedium, K041119 K<082572… | 2007 |
| * | K082572 | Uss Iliosacral, Uss PolyaxialSummary page 1…175 Abbott Spine Pathfinder, K071 174 Synthes UISS Illiosacral and Polyaxial, DePuy Expedium, K041119 K<082572 Medtronic CID Horizon, K1 11457 Synthes Matrix System, K<092929… | 2008 |
| * | K041119 | Expedium Spine SystemSummary page 1…Synthes Click'X, K031 175 Abbott Spine Pathfinder, K071 174 Synthes UISS Illiosacral and Polyaxial, DePuy Expedium, K041119 K<082572 Medtronic CID Horizon, K1 11457 Synthes… | 2004 |
| * | K111457 | CD Horizon Spinal SystemSummary page 1…Synthes UISS Illiosacral and Polyaxial, DePuy Expedium, K041119 K<082572 Medtronic CID Horizon, K1 11457 Synthes Matrix System, K<092929 Synthes Matrix System, K<093668… | 2011 |
| * | K092929 | Synthes Matrix SystemSummary page 1…ePuy Expedium, K041119 K<082572 Medtronic CID Horizon, K1 11457 Synthes Matrix System, K<092929 Synthes Matrix System, K<093668 Synthes Matrix System, 1100952… | 2009 |
| * | K093668 | Synthes Matrix Mis RodsSummary page 1…2 Medtronic CID Horizon, K1 11457 Synthes Matrix System, K<092929 Synthes Matrix System, K<093668 Synthes Matrix System, 1100952 Synthes Matrix System, 1100634… | 2010 |
| * | K100952 | Modification to Synthes Matrix SystemSummary page 1…K1 11457 Synthes Matrix System, K<092929 Synthes Matrix System, K<093668 Synthes Matrix System, 1100952 Synthes Matrix System, 1100634 Synthes 6.0 CoCr and CP Ti-3 Rods,… | 2010 |
| * | K100634 | Synthes Matrix SystemSummary page 1…, K<092929 Synthes Matrix System, K<093668 Synthes Matrix System, 1100952 Synthes Matrix System, 1100634 Synthes 6.0 CoCr and CP Ti-3 Rods, K<103287 Device Synthes MIR… | 2010 |
| * | K103287 | Synthes 6.0 Cocr and CPT TI-3 RodsSummary page 1…thes Matrix System, 1100952 Synthes Matrix System, 1100634 Synthes 6.0 CoCr and CP Ti-3 Rods, K<103287 Device Synthes MIRS isan addition to Synthes' existing non-cervical spinal fixation Description: devi… | 2011 |
What descends from it? (93)
See all 933 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (1 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Sep 7, 2012 | Class II | Z-0395-2014 | Use error | This action is being initiated following a detailed investigation in response to reported complaints of post-operative locking cap loosening. Synthes has concluded that if the construct is mis-aligned during final tightening, the… |
| Sep 7, 2012 | Class II | Z-0396-2014 | Use error | This action is being initiated following a detailed investigation in response to reported complaints of post-operative locking cap loosening. Synthes has concluded that if the construct is mis-aligned during final tightening, the… |
| Jun 18, 2012 | Class II | Z-0001-2013 | Labeling design | Synthes is initiating a Medical Device Labeling Correction following a detailed review of the current labeling in response to reported complaints. Synthes has identified technique measures and has updated the labeling associated with this… |
Relatives with a Class I recall
Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.
- K100952Modification to Synthes Matrix SystemSynthes Spine · 2010 · Direct predicate · ◆ in the 2010 ancestors bar of FIG. 11 Class I recall
What does this lineage say?
- The line of descent spans 16 years and passes through 4 companies; a new generation was cleared every 7 months on median.
- 10 of the 75 ancestors have a recall of any class; 1 has a Class I recall.
- Of its descendants, K120571 (Synthes Spine, 2012) has gone furthest, with 74 descendants of its own.
- 10 other devices also cite its predicate K963045.
How does its category compare?
All NKB devicesNKB Thoracolumbosacral Pedicle Screw System: FDA decisions, review times, recalls and adverse event reports over 20 years. 2011, this device’s year, is highlighted.
FDA decisions per year · NKB
24in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · NKB
61in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · NKB
1in 2025
Class I (1 since 2007) Class II/III not classified
Adverse event reports per year · NKB
1,171in 2025
MAUDE reports naming product code NKB, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 38 | 87 | 4 | 34 |
| 2008 | 36 | 59 | 5 | 82 |
| 2009 | 44 | 71 | 33 | 171 |
| 2010 | 37 | 111 | 4 | 462 |
| 2011 | 48 | 84 | 3 | 577 |
| 2012 | 60 | 79 | 13 | 1,747 |
| 2013 | 35 | 73 | 0 | 1,962 |
| 2014 | 46 | 90 | 3 (1) | 1,671 |
| 2015 | 55 | 90 | 3 | 1,446 |
| 2016 | 50 | 84 | 1 | 1,585 |
| 2017 | 63 | 69 | 1 | 1,618 |
| 2018 | 56 | 61 | 3 | 1,684 |
| 2019 | 39 | 84 | 1 | 1,915 |
| 2020 | 48 | 68 | 1 | 2,076 |
| 2021 | 32 | 61 | 0 | 1,745 |
| 2022 | 34 | 88 | 5 | 1,339 |
| 2023 | 44 | 72 | 2 | 919 |
| 2024 | 39 | 57 | 3 | 1,614 |
| 2025 | 24 | 61 | 1 | 1,171 |
| 2026 | 30 | 91 | 3 | — |
What is it indicated for?
The Synthes USS are non-cervical spinal fixation devices intended for posterior pedicle screw fixation (T1-52/ilium), posterior hook fixation (TI1-5), or anterolateral fixation (T8I-L5). Pedicle screw fixation is limited to skeletally mature patients with the exception of the Small Stature USS, which includes small stature and pediatric patients. These devices are indicated as an adjunct to fusion for all of the following indications: degenerative disc…
Read the full statement (374 words)
The Synthes USS are non-cervical spinal fixation devices intended for posterior pedicle screw fixation (T1-52/ilium), posterior hook fixation (TI1-5), or anterolateral fixation (T8I-L5). Pedicle screw fixation is limited to skeletally mature patients with the exception of the Small Stature USS, which includes small stature and pediatric patients. These devices are indicated as an adjunct to fusion for all of the following indications: degenerative disc disease (defined as discogenic back pain with degeneration of the disc confirmed by history and radiographic studies), spondylolisthesis, trauma (i.e., fracture or dislocation), deformities or curvatures (i.e., scoliosis, kyphosis, and/or lordosis, Scheuermann's Disease), tumor, stenosis, and failed previous fusion (pseudoarthrosis).
When treating patients with Degenerative Disc Disease (ODD), transverse bars are not cleared for use as part of the posterior pedicle screw construct.
When used with the 3.5 mm/6.Omm parallel connectors, the Synthes USS 6.0 mm rod systems can be linked to the CerviFix 3.5mm Systems. In addition, when used with 3.5 mm/5.Omm parallel connectors, the Synthes Small Stature UISS can be linked to the CerviFix 3.5mm Systems. When used with the 5.0 mm/6.Ommn parallel connectors, the Synthes Small Stature USS can be linked to the Synthes UISS 6.0 mm rod systems.
When used with the 3.5 mm/6.Omm and 4.0 mmI6.Omm tapered rods, the Synthes USS 6.0mmn rod systems can be linked to the CerviFix 3.5 mm and 4.0 mm Systems, respectively. When used with the 3.5 mm/5.Smm and 4.0 mmIS.5 mm tapered rods, Matrix or MIRS can be linked to the CerviFix 3.5 mm and 4.0 mm Systems, respectively. When used with the 5.5 mm/6.Omm tapered rods, the Synthes UISS 6.0 mim rod systems can be linked to the Matrix System or MIRS.
In addition, Synthes USS 6.0 min rod systems can be interchanged with all UISS 6.0 mm rods and transconnectors except Synthes 6.0 mim cobalt-chromium-molybdenumn alloy and titanium grade 3 rods, which can only be used with Pangea.
Synthes USS
o 6.0 mmn Rod Systems: USS Side-Opening, USS Dual-Opening, USS VAS variable axis components, USS Fracture, Click'X, Click'X Monoaxial, Pangea, Pangea Monoaxial, USS Polyaxial, USS Iliosacral, ClampFix
o 5.5 mm Rod System: Matrix, MIRS
o 5.0 mm Rod System: UISS Small Stature
CerviFix
o 3.5 mim Rod Systems: CerviFix, Axon, Synapse
o 4.0 mm Rod System: Synapse
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K113044 · printed Nov 6, 2026
Cite this page
510(k) Report. “K113044: Synthes Mirs.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K113044
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026