510(k) Report

510(k) · Cleared

Recalled · Class II · 2019

Ana-Screen with MDSS

K113610510(k) SpecialCleared Jul 9, 2012216-day reviewClass II21 CFR 866.5100Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Bio-Rad Laboratories · LKJ Antinuclear Antibody, Antigen, Control

Cleared on Jul 9, 2012 as substantially equivalent to K043341 (Bio-Rad Laboratories, Inc., 2005) after a 216-day review. Its family tree reaches back 2 generations to 1995. It has been recalled once.

Decided
Jul 9, 2012
Review
216 days
Class
Class II
Product code
LKJ
Recalls
1
Predicates
1

Its longest line of descent runs back 2 generations to K941596 (1995). No later device cites it as a predicate yet.

  1. Root · 2 generations backK941596 Remedi HS Drug Profiling SystemBio-Rad · 1995
  2. 1 generation backK043341 Bioplex 2200 Ana Screen with Medical Decision Support Software for…Bio-Rad Laboratories, Inc. · 2005 · Recalled
  3. This deviceK113610 Ana-Screen with MDSSBio-Rad Laboratories · 2012
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K941596Remedi HS Drug Profiling SystemBio-Rad1995—
−1K043341Bioplex 2200 Ana Screen with Medical Decision Support Software for Use with…Bio-Rad Laboratories, Inc.20052
0 (this device)K113610Ana-Screen with MDSSBio-Rad Laboratories2012—
FIG. 1 — Lineage of K113610, 1995–2012Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LKJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LKJ device

  1. #1 K210902 EliA Ro52, EliA Ro60score 4.0 · 2 generations · no Class I recall
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K043341Bioplex 2200 Ana Screen with Medical Decision Support Software for Use with Bioplex 2200…
Summary page 2
…creen with MDSS Regulation Number 862.3100 Product Code NVI Legally Marketed Predicate Device BioPlex® 2200 ANA Screen with MDSS, k043341 Intended Use The BioPlex® 2200 ANA Screen is intended for the qualitative screening of specific antinuclear antibodies (ANA), th…
Bio-Rad Laboratories, Inc.20052

Also cleared against K043341: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Nov 1, 2019Class IIZ-0082-2022Process controlA new lot of ANA screen control and any subsequent control lots are incompatible with older lot numbers of ANA calibrators and ANA reagent packs.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 17 years and passes through 3 companies; a new generation was cleared every 10.6 years on median.
  • 1 of the 2 ancestors has a recall of any class.
  • 1 other device also cites its predicate K043341.

How does its category compare?

All LKJ devices

LKJ Antinuclear Antibody, Antigen, Control: FDA decisions, review times, recalls and adverse event reports over 20 years. 2012, this device’s year, is highlighted.

FDA decisions per year · LKJ

1in 2022

2008: 12009: 12012: 12022: 1
2007high 1 (2008) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LKJ

Too few LKJ 510(k)s in any year since 2007 to give a median.

Recalls per year · LKJ

1in 2019

2007: 12010: 72015: 12017: 12019: 1
2007high 7 (2010) · low 0 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LKJ

2in 2018

2010: 22011: 172017: 22018: 2
2007high 17 (2011) · low 0 (2007)2025

MAUDE reports naming product code LKJ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—10
20081—00
20091—00
20100—72
20110—017
20121—00
20130—00
20140—00
20150—10
20160—00
20170—12
20180—02
20190—10
20200—00
20210—00
20221—00
20230—00
20240—00
20250—00
20260—0—

What is it indicated for?

The BioPlex® 2200 ANA Screen is intended for the qualitative screening of specific antinuclear antibodies (ANA), the quantitative detection of antibody to dsDNA, and the semi-quantitative detection of ten (10) separate antibody assays (Chromatin, Ribosomal Protein, SS-A, SS-B, Sm, SmRNP, RNP, Scl-70, Jo-i, and Centromere B) in human serum and/or EDTA or heparinized plasma. The ANA Screen is used to screen serum or plasma (EDTA, heparin) samples and…

Read the full statement (195 words)

The BioPlex® 2200 ANA Screen is intended for the qualitative screening of specific antinuclear antibodies (ANA), the quantitative detection of antibody to dsDNA, and the semi-quantitative detection of ten (10) separate antibody assays (Chromatin, Ribosomal Protein, SS-A, SS-B, Sm, SmRNP, RNP, Scl-70, Jo-i, and Centromere B) in human serum and/or EDTA or heparinized plasma.

The ANA Screen is used to screen serum or plasma (EDTA, heparin) samples and detects the presence of antinuclear antibodies as an aid in the diagnosis of systemic autoimmune diseases (Systemic Ltipus Erythematosus [SLE], Mixed Connective Tissue Disease [MCTD], Undifferentiated Connective Tissue-Disease [UCTD], Sjdgren's Syndrome [SS], Scieroderma [Systemic Sclerosis], Dermatomyositis, Polymyositis, Rheumatoid Arthritis [RA], CREST Syndrome, and Raynaud's Phenomenon) in conjunction with clinical findings and other laboratory tests.

The ANA Screen is intended for use, with the Bio-Rad BioPlex 2200 System.

The BioPlex 2200 Medical Decision Support Software (MDSS), used in conjunction -with the ANA Screen, is an optional laboratory tool that associates patient antibody results from the AINA Screeni with predefmied MLDSS profiles that have been correlated with the following systemic autoimmune diseases: Systemic Lupus Erythematosus (SLE), Mixed Connective Tissue Disease (MCTD), Sje~gren's Syndrome (SS), Sclerodenna (Systemic Sclerosis) and Polymyositis.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K113610: Ana-Screen with MDSS.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K113610

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026