510(k) Report

510(k) · Cleared

Recalled · Class II · 2018

Sterile Neoprene Powder-Free Surgical Gloves with Nitrile Coating

K113707510(k) TraditionalCleared Apr 27, 2012133-day reviewClass I21 CFR 878.4460Recalls 8

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Cardinal Health-Medical Products and Services · KGO Surgeon'S Gloves

Cleared on Apr 27, 2012 as substantially equivalent to K102500 (Cardinal Health, Inc., 2010) and 1 other predicate after a 133-day review. Its family tree reaches back 2 generations to 2001. 2 later devices descend from it. It has been recalled 8 times.

Decided
Apr 27, 2012
Review
133 days
Class
Class I
Product code
KGO
Recalls
8
Predicates
2

Its longest line of descent runs back 2 generations to K013302 (2001). 2 later devices descend from it, 1 citing it directly.

Descendants, by year cleared 2016: 1 descendant cleared2017: 1 descendant clearedK013302 · Duraprene Sterile Synthetic Powder-Free Surgical Gloves with Tested for Use with Chemotherapy Drugs Labeling Claim · Allegiance Healthcare Corp. · 2001K102500 · Sterile Neoprene Powder-Free Surgical Gloves with Nitrile Coating · Cardinal Health, Inc. · 2010200020052010201520202025
  1. Root · 2 generations backK013302 Duraprene Sterile Synthetic Powder-Free Surgical Gloves with Tested…Allegiance Healthcare Corp. · 2001
  2. 1 generation backK102500 Sterile Neoprene Powder-Free Surgical Gloves with Nitrile CoatingCardinal Health, Inc. · 2010
  3. This deviceK113707 Sterile Neoprene Powder-Free Surgical Gloves with Nitrile CoatingCardinal Health-Medical Products and Services · 2012
  4. Descendant · cites it directly · 1 of its ownK153316 Cardinal Health Sterile Neoprene Powder-Free Surgical Gloves with…Cardinal Health, Inc. · 2016
  5. Descendant · 2 generations on · 0 of its ownK161823 Powder Free Nitrile Surgical Glove, Sterile, Tested for use with…Wrp Asia Pacific Sdn. Bhd. · 2017

Most influential descendants

Showing 2 of 2 · See all
  • K153316Cardinal Health Sterile Neoprene Powder-Free Surgical Gloves with Nitrile Coating and…Cardinal Health, Inc. · 2016 · cites it directly1descendant
  • K161823Powder Free Nitrile Surgical Glove, Sterile, Tested for use with Chemotherapy DrugsWrp Asia Pacific Sdn. Bhd. · 2017 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K013302Duraprene Sterile Synthetic Powder-Free Surgical Gloves with Tested for Use…Allegiance Healthcare Corp.2001—
−1K102500Sterile Neoprene Powder-Free Surgical Gloves with Nitrile CoatingCardinal Health, Inc.2010—
0 (this device)K113707Sterile Neoprene Powder-Free Surgical Gloves with Nitrile CoatingCardinal Health-Medical Products and Services2012—
+1K153316Cardinal Health Sterile Neoprene Powder-Free Surgical Gloves with Nitrile…Cardinal Health, Inc.2016—
+2K161823Powder Free Nitrile Surgical Glove, Sterile, Tested for use with Chemotherapy…Wrp Asia Pacific Sdn. Bhd.2017—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201610
201710
FIG. 1 — Lineage of K113707, 2001–2017Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in KGO? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new KGO device

  1. #1 K192328 JR.MEDIK Latex Surgeon’s Gloves Powder Freescore 15.2 · 5 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K102500Sterile Neoprene Powder-Free Surgical Gloves with Nitrile Coating
Summary page 1
…1 CFR 878.4460 Product Code(s): 79KGO Legally marketed 1. Ourapreneq SMVT Sterile Polyisoprene Powder-Free Surgical Gloves, device(s) to which 510(k) K102500, (product code 79KG0). equivalence is claimed: 2. Duraprene Sterile Neoprene Powder-Free Surgical Gloves, 510(k)…
Cardinal Health, Inc.2010—
*K013302Duraprene Sterile Synthetic Powder-Free Surgical Gloves with Tested for Use with…
Summary page 1
…(s) to which 510(k) K102500, (product code 79KG0). equivalence is claimed: 2. Duraprene Sterile Neoprene Powder-Free Surgical Gloves, 510(k) K013302, (product code 79KG0) Reason for 510(k) Addition of new indications for use: Tested for Use with Chemotherapy Submission:…
Allegiance Healthcare Corp.2001—

Also cleared against K102500: 1 other device →

What descends from it? (2)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K153316Cardinal Health Sterile Neoprene Powder-Free Surgical Gloves with Nitrile Coating and…Cardinal Health, Inc.20161

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Oct 31, 2018Class IIZ-0631-2019Labeling mix-upsLabeling issue in that the breakthrough (i.e., permeation) times for two chemotherapy drugs (Carmustine and Thiotepa) stated on the wallet (primary packaging) of the Protexis Neoprene surgical gloves are incorrect. Additionally…
Oct 31, 2018Class IIZ-0634-2019Labeling mix-upsLabeling issue in that the breakthrough (i.e., permeation) times for two chemotherapy drugs (Carmustine and Thiotepa) stated on the wallet (primary packaging) of the Protexis Neoprene surgical gloves are incorrect. Additionally…
Oct 31, 2018Class IIZ-0632-2019Labeling mix-upsLabeling issue in that the breakthrough (i.e., permeation) times for two chemotherapy drugs (Carmustine and Thiotepa) stated on the wallet (primary packaging) of the Protexis Neoprene surgical gloves are incorrect. Additionally…
Oct 31, 2018Class IIZ-0633-2019Labeling mix-upsLabeling issue in that the breakthrough (i.e., permeation) times for two chemotherapy drugs (Carmustine and Thiotepa) stated on the wallet (primary packaging) of the Protexis Neoprene surgical gloves are incorrect. Additionally…
Oct 31, 2018Class IIZ-0635-2019Labeling mix-upsLabeling issue in that the breakthrough (i.e., permeation) times for two chemotherapy drugs (Carmustine and Thiotepa) stated on the wallet (primary packaging) of the Protexis Neoprene surgical gloves are incorrect. Additionally…
Oct 31, 2018Class IIZ-0638-2019Labeling mix-upsLabeling issue in that the breakthrough (i.e., permeation) times for two chemotherapy drugs (Carmustine and Thiotepa) stated on the wallet (primary packaging) of the Protexis Neoprene surgical gloves are incorrect. Additionally…
Oct 31, 2018Class IIZ-0636-2019Labeling mix-upsLabeling issue in that the breakthrough (i.e., permeation) times for two chemotherapy drugs (Carmustine and Thiotepa) stated on the wallet (primary packaging) of the Protexis Neoprene surgical gloves are incorrect. Additionally…
Oct 31, 2018Class IIZ-0637-2019Labeling mix-upsLabeling issue in that the breakthrough (i.e., permeation) times for two chemotherapy drugs (Carmustine and Thiotepa) stated on the wallet (primary packaging) of the Protexis Neoprene surgical gloves are incorrect. Additionally…

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 11 years and passes through 3 companies; a new generation was cleared every 8.9 years on median.
  • None of the 2 ancestors has a recall.
  • Of its descendants, K153316 (Cardinal Health, Inc., 2016) has gone furthest, with 1 descendant of its own.
  • 1 other device also cites its predicate K102500.

How does its category compare?

All KGO devices

KGO Surgeon'S Gloves: FDA decisions, review times, recalls and adverse event reports over 20 years. 2012, this device’s year, is highlighted.

FDA decisions per year · KGO

1in 2025

2007: 102008: 22009: 32010: 62011: 112012: 72013: 62014: 72015: 122016: 92017: 122018: 72019: 112020: 152021: 142022: 62023: 142024: 22025: 12026 (partial year): 2
2007high 15 (2020) · low 1 (2025)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · KGO

185in 2023

2007: 113 days median2009: 48 days median2010: 87 days median2011: 90 days median2012: 133 days median2013: 184 days median2014: 257 days median2015: 225 days median2016: 218 days median2017: 111 days median2018: 194 days median2019: 204 days median2020: 117 days median2021: 199 days median2022: 127 days median2023: 185 days median
2007high 257 (2014) · low 48 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · KGO

2in 2023

2009: 152010: 12016: 22017: 12018: 82022: 22023: 2
2007high 15 (2009) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · KGO

21in 2025

2007: 132008: 82009: 142010: 162011: 142012: 142013: 412014: 282015: 112016: 152017: 202018: 152019: 512020: 152021: 142022: 102023: 282024: 182025: 21
2007high 51 (2019) · low 8 (2008)2025

MAUDE reports naming product code KGO, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200710113013
20082—08
20093481514
2010687116
20111190014
20127133014
20136184041
20147257028
201512225011
20169218215
201712111120
20187194815
201911204051
202015117015
202114199014
20226127210
202314185228
20242—018
20251—021
20262—0—

What is it indicated for?

These powder-free sterile light brown colored surgeon's gloves are a disposable device made of synthetic rubber intended to be worn by operating room personnel to protect a surgical wound from contamination. In addition, these gloves were tested for use with chemotherapy drugs in accordance with ASTM D6978 Standard Practice for Assessment of Medical Gloves to Permeation by Chemotherapy Drugs: 1. Carmustine (BCNUJ) (3.3 mg/mi) — 0.2 2. Cisplastia, (1.0…

Read the full statement (150 words)

These powder-free sterile light brown colored surgeon's gloves are a disposable device made of synthetic rubber intended to be worn by operating room personnel to protect a surgical wound from contamination. In addition, these gloves were tested for use with chemotherapy drugs in accordance with ASTM D6978 Standard Practice for Assessment of Medical Gloves to Permeation by Chemotherapy Drugs:

1. Carmustine (BCNUJ) (3.3 mg/mi) — 0.2

2. Cisplastia, (1.0 mg/mi) — >240

3. Cyclophosphamide (20 mg/nil) — >240

4. Doxorubicin HCl (2.0 mg/mi) — >240

5. Etoposide (20 mg/mi) — >240

6. Fluorouracil (50.0 mg/nil) — >240

7. Methotrexate (25 mg/mi) — >240

8. Paclitaxel (6.0 mg/mi) — >240

9. Thiotepa (10.0 mg/mi) — 82.2

10. Vincristine Sulfate (1.0 mg/nil) — >240

Please note that the following drug has extremely low permeation time of less than 30 minutes: Carmustine (BCNUL) (3.3 mg/mi) has a minimum breakthrough time of 0.20 minute.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K113707: Sterile Neoprene Powder-Free Surgical Gloves with Nitrile Coating.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K113707

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026