Spinal Elements Posterior Cervical/Thoracic Spinal System

K120467510(k) TraditionalCleared Jul 30, 2012166-day reviewClass II21 CFR 888.3070

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Spinal Elements, Inc. · NKB Thoracolumbosacral Pedicle Screw System

Cleared on Jul 30, 2012 as substantially equivalent to K052201 (Alphatec Spine, Inc., 2005) and 4 other predicates after a 166-day review. Its family tree reaches back 10 generations to 1985. 1 later device descends from it.

Decided
Jul 30, 2012
Review
166 days
Class
Class II
Product code
NKB
Recalls
None
Predicates
5

Its longest line of descent runs back 10 generations to K853033 (1985). 36 ancestors in all. 1 later device descends from it, 1 citing it directly.

  1. Root · 10 generations backK853033 Hartshill Rect & Wires, Spinal Fixation SystemA.W. Showell (Surgicraft), Ltd. · 1985
  2. 6 generations between
  3. 3 generations backK041203 Summit Oct Spinal SystemDepuy Spine, Inc. · 2004
  4. 2 generations backK042508 Sumit Oct Spinal System and Mountaineer Oct Spinal SystemDepuy Spine, Inc. · 2004
  5. 1 generation backK062934 SierraSeaspine, Inc. · 2006
  6. This deviceK120467 Spinal Elements Posterior Cervical/Thoracic Spinal SystemSpinal Elements, Inc. · 2012
  7. Descendant · cites it directly · 0 of its ownK131427 LOTUSSpinal Elements, Inc. · 2013
Show all 10 generations
  1. Root · 10 generations backK853033 Hartshill Rect & Wires, Spinal Fixation SystemA.W. Showell (Surgicraft), Ltd. · 1985
  2. 9 generations backK965221 Ransford Cervical Fixation SystemSurgicraft, Ltd. · 1997
  3. 8 generations backK982322 Synthes Spine Occipital-Cervical Plate/Rod and Hook SystemSynthes (Usa) · 1998
  4. 7 generations backK002733 Summit Occipito-Cervico-Thoracic (Oct) Spinal SystemDepuyacromed · 2000
  5. 6 generations backK013222 Summit Occipito-Cervico- Thoracic (Oct) Spinal SystemDepuyacromed · 2001
  6. 5 generations backK022190 Modification to Summit Occipito-Cervico-Thoracic (Oct) Spinal SystemDepuyacromed · 2002
  7. 4 generations backK030103 Summit Oct Spinal System Minipolyaxial ScrewsDepuyacromed · 2003
  8. 3 generations backK041203 Summit Oct Spinal SystemDepuy Spine, Inc. · 2004
  9. 2 generations backK042508 Sumit Oct Spinal System and Mountaineer Oct Spinal SystemDepuy Spine, Inc. · 2004
  10. 1 generation backK062934 SierraSeaspine, Inc. · 2006
  11. This deviceK120467 Spinal Elements Posterior Cervical/Thoracic Spinal SystemSpinal Elements, Inc. · 2012

Most influential descendants

Showing 1 of 1 · See all
  • K131427LOTUSSpinal Elements, Inc. · 2013 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−10K853033Hartshill Rect & Wires, Spinal Fixation SystemA.W. Showell (Surgicraft), Ltd.1985—
−9K965221Ransford Cervical Fixation SystemSurgicraft, Ltd.1997—
−8K982322Synthes Spine Occipital-Cervical Plate/Rod and Hook SystemSynthes (Usa)1998—
−7K002733Summit Occipito-Cervico-Thoracic (Oct) Spinal SystemDepuyacromed2000—
−6K013222Summit Occipito-Cervico- Thoracic (Oct) Spinal SystemDepuyacromed2001—
−5K022190Modification to Summit Occipito-Cervico-Thoracic (Oct) Spinal SystemDepuyacromed2002—
−4K030103Summit Oct Spinal System Minipolyaxial ScrewsDepuyacromed2003—
−3K041203Summit Oct Spinal SystemDepuy Spine, Inc.2004—
−2K042508Sumit Oct Spinal System and Mountaineer Oct Spinal SystemDepuy Spine, Inc.2004—
−1K062934SierraSeaspine, Inc.2006—
0 (this device)K120467Spinal Elements Posterior Cervical/Thoracic Spinal SystemSpinal Elements, Inc.2012—
+1K131427LOTUSSpinal Elements, Inc.2013—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199940
200010
200130
200250
200460
200550
200610
200710

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201310
FIG. 1 — Lineage of K120467, 1985–2013Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in NKB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new NKB device

  1. #1 K223494 CD Horizon Spinal Systemscore 40.4 · 30 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (5)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K052201Solanas Posterior Stabilization System
Summary page 2
…d. Substantial Equivalence Spinal Elements Posterior Cervical/Thoracic Spinal System is substantially equivalent to Alphatec's Solanas® Posterior Stabilization System (K052201 and K071380), Depuy Spine's Summit®o Ocipito-Cervico-Thoracic (OCT) Spinal System (K002733 and K010681), and SeaSpine's Sierra Sy…
Alphatec Spine, Inc.20053
*K071380Modification to Solanas Posterior Stabilization System
Summary page 2
…tial Equivalence Spinal Elements Posterior Cervical/Thoracic Spinal System is substantially equivalent to Alphatec's Solanas® Posterior Stabilization System (K052201 and K071380), Depuy Spine's Summit®o Ocipito-Cervico-Thoracic (OCT) Spinal System (K002733 and K010681), and SeaSpine's Sierra System (K06293…
Alphatec Spine, Inc.20073
*K002733Summit Occipito-Cervico-Thoracic (Oct) Spinal System
Summary page 2
…ubstantially equivalent to Alphatec's Solanas® Posterior Stabilization System (K052201 and K071380), Depuy Spine's Summit®o Ocipito-Cervico-Thoracic (OCT) Spinal System (K002733 and K010681), and SeaSpine's Sierra System (K062934) in indications, general design features, performance, function, and material…
Depuyacromed2000—
*K010681Summit Occipito-Cervico-Thoracic (Oct) Spinal System
Summary page 2
…equivalent to Alphatec's Solanas® Posterior Stabilization System (K052201 and K071380), Depuy Spine's Summit®o Ocipito-Cervico-Thoracic (OCT) Spinal System (K002733 and K010681), and SeaSpine's Sierra System (K062934) in indications, general design features, performance, function, and materials. === Page…
Depuyacromed2001—
*K062934Sierra
Summary page 2
…rior Stabilization System (K052201 and K071380), Depuy Spine's Summit®o Ocipito-Cervico-Thoracic (OCT) Spinal System (K002733 and K010681), and SeaSpine's Sierra System (K062934) in indications, general design features, performance, function, and materials. DEPARTMENT OF HEALTH & HUMAN…
Seaspine, Inc.2006—

Also cleared against K052201: 7 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K131427LOTUSSpinal Elements, Inc.20130

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 27 years and passes through 7 companies; a new generation was cleared every 1.3 years on median.
  • 3 of the 36 ancestors have a recall of any class.
  • Of its descendants, K131427 (Spinal Elements, Inc., 2013) has gone furthest, with 0 descendants of its own.
  • 7 other devices also cite its predicate K052201.

How does its category compare?

All NKB devices

NKB Thoracolumbosacral Pedicle Screw System: FDA decisions, review times, recalls and adverse event reports over 20 years. 2012, this device’s year, is highlighted.

FDA decisions per year · NKB

24in 2025

2007: 382008: 362009: 442010: 372011: 482012: 602013: 352014: 462015: 552016: 502017: 632018: 562019: 392020: 482021: 322022: 342023: 442024: 392025: 242026 (partial year): 30
2007high 63 (2017) · low 24 (2025)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · NKB

61in 2025

2007: 87 days median2008: 59 days median2009: 71 days median2010: 111 days median2011: 84 days median2012: 79 days median2013: 73 days median2014: 90 days median2015: 90 days median2016: 84 days median2017: 69 days median2018: 61 days median2019: 84 days median2020: 68 days median2021: 61 days median2022: 88 days median2023: 72 days median2024: 57 days median2025: 61 days median2026 (partial year): 91 days median
2007high 111 (2010) · low 57 (2024)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · NKB

1in 2025

2007: 42008: 52009: 332010: 42011: 32012: 132014: 3, 1 Class I2015: 32016: 12017: 12018: 32019: 12020: 12022: 52023: 22024: 32025: 12026 (partial year): 3
2007high 33 (2009) · low 0 (2013)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · NKB

1,171in 2025

2007: 342008: 822009: 1712010: 4622011: 5772012: 1,7472013: 1,9622014: 1,6712015: 1,4462016: 1,5852017: 1,6182018: 1,6842019: 1,9152020: 2,0762021: 1,7452022: 1,3392023: 9192024: 1,6142025: 1,171
2007high 2,076 (2020) · low 34 (2007)2025

MAUDE reports naming product code NKB, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20073887434
20083659582
2009447133171
2010371114462
201148843577
20126079131,747
2013357301,962
201446903 (1)1,671
2015559031,446
2016508411,585
2017636911,618
2018566131,684
2019398411,915
2020486812,076
2021326101,745
2022348851,339
202344722919
2024395731,614
2025246111,171
202630913—

What is it indicated for?

The Spinal Elements Posterior Cervical/Thoracic Spinal System is intended for posterior fixation of the cervical and thoracic spine (CI-T3) for the following conditions: degenerative disc disease (neck pain of discogenic origin with degeneration of the disc as confirmed by patient history and radiographic studies); spondylolisthesis; spinal stenosis; trauma (fracture/dislocation); failed previous fusion; tumors

The use of polyaxial pedicle screws is limited to placement in T I -T3 for treating thoracic conditions only. The screws are not intended to be placed in the cervical spine.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K120467: Spinal Elements Posterior Cervical/Thoracic Spinal System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K120467

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026