510(k) Report

510(k) · Cleared

Cleared

Synapse 3D Nodule Analysis

K120679510(k) TraditionalCleared Jun 1, 201287-day reviewClass II21 CFR 892.2050

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Fujifilm Medical Systems U.S.A, Inc. · LLZ System, Image Processing, Radiological

Cleared on Jun 1, 2012 as substantially equivalent to K042694 (GE Medical Systems, 2004) after an 87-day review. Its family tree reaches back 6 generations to 1991.

Decided
Jun 1, 2012
Review
87 days
Class
Class II
Product code
LLZ
Recalls
None
Predicates
1

Its longest line of descent runs back 6 generations to K913770 (1991). No later device cites it as a predicate yet.

  1. Root · 6 generations backK913770 Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co. · 1991
  2. 5 generations backK963345 Advantage Windows Tissue Volume OptionGE Medical Systems · 1996
  3. 4 generations backK013381 Advanced Lung Analysis-1General Electric Co. · 2001
  4. 3 generations backK022013 Lungcare CT Software PackageSiemens Medical Solutions USA, Inc. · 2002
  5. 2 generations backK033374 Lungcare CT Software Package with Extended FunctionalitySiemens AG Medical Solutions · 2003
  6. 1 generation backK042694 Advanced Lung Analysis IIGE Medical Systems · 2004
  7. This deviceK120679 Synapse 3D Nodule AnalysisFujifilm Medical Systems U.S.A, Inc. · 2012
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−6K913770Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co.1991—
−5K963345Advantage Windows Tissue Volume OptionGE Medical Systems1996—
−4K013381Advanced Lung Analysis-1General Electric Co.2001—
−3K022013Lungcare CT Software PackageSiemens Medical Solutions USA, Inc.2002—
−2K033374Lungcare CT Software Package with Extended FunctionalitySiemens AG Medical Solutions2003—
−1K042694Advanced Lung Analysis IIGE Medical Systems2004—
0 (this device)K120679Synapse 3D Nodule AnalysisFujifilm Medical Systems U.S.A, Inc.2012—
FIG. 1 — Lineage of K120679, 1991–2012Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LLZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LLZ device

  1. #1 K230955 syngo Application Softwarescore 21.5 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K042694Advanced Lung Analysis II
Summary page 2
…2 === FUJIFILM Medical Systems U.S.A., Inc. Synapse 3D Nodule Analysis 510O(k) Predicate Device: *Advantage Windows Lung Analysis: GE Healthcare (GE Medical Systems) (K042694). Description of the Device Synapse 3D Nodule Analysis is an optional software module that works with Synapse 3D Base Tools (…
GE Medical Systems2004—

Also cleared against K042694: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 21 years and passes through 5 companies; a new generation was cleared every 4.8 years on median.
  • None of the 6 ancestors has a recall.
  • 2 other devices also cite its predicate K042694.

How does its category compare?

All LLZ devices

LLZ System, Image Processing, Radiological: FDA decisions, review times, recalls and adverse event reports over 20 years. 2012, this device’s year, is highlighted.

FDA decisions per year · LLZ

58in 2025

2007: 762008: 942009: 702010: 512011: 1062012: 822013: 952014: 782015: 642016: 822017: 782018: 1042019: 742020: 812021: 832022: 652023: 872024: 622025: 582026 (partial year): 45
2007high 106 (2011) · low 51 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LLZ

173in 2025

2007: 36 days median2008: 52 days median2009: 62 days median2010: 98 days median2011: 79 days median2012: 87 days median2013: 84 days median2014: 89 days median2015: 90 days median2016: 90 days median2017: 107 days median2018: 105 days median2019: 107 days median2020: 115 days median2021: 116 days median2022: 137 days median2023: 157 days median2024: 131 days median2025: 173 days median2026 (partial year): 110 days median
2007high 173 (2025) · low 36 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LLZ

11in 2025

2007: 202008: 322009: 212010: 172011: 302012: 122013: 642014: 62015: 162016: 122017: 52018: 72019: 22020: 62021: 32022: 42023: 82024: 62025: 112026 (partial year): 14
2007high 64 (2013) · low 2 (2019)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LLZ

116in 2025

2007: 1522008: 1542009: 1452010: 1452011: 4542012: 2662013: 1,1302014: 15,6312015: 2112016: 2902017: 1042018: 722019: 882020: 822021: 702022: 282023: 262024: 422025: 116
2007high 15,631 (2014) · low 26 (2023)2025

MAUDE reports naming product code LLZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007763620152
2008945232154
2009706221145
2010519817145
20111067930454
2012828712266
20139584641,130
20147889615,631
2015649016211
2016829012290
2017781075104
2018104105772
201974107288
202081115682
202183116370
202265137428
202387157826
202462131642
20255817311116
20264511014—

What is it indicated for?

Synapse 3D Nodule Analysis is medical imaging software used with Synapse 3D Base Tools that is intended to provide trained medical professionals with tools to aid them in reading, interpreting, reporting, and treatment planning. Synapse 3D Nodule Analysis accepts DICOM compliant medical images acquired from CT and PT. This product is not intended for use with or for the primary diagnostic interpretation of Mammography images. Addition to Synapse 3D Base…

Read the full statement (183 words)

Synapse 3D Nodule Analysis is medical imaging software used with Synapse 3D Base Tools that is intended to provide trained medical professionals with tools to aid them in reading, interpreting, reporting, and treatment planning. Synapse 3D Nodule Analysis accepts DICOM compliant medical images acquired from CT and PT.

This product is not intended for use with or for the primary diagnostic interpretation of Mammography images.

Addition to Synapse 3D Base Tools, Synapse 3D Nodule Analysis is intended to;

" use non-contrast and contrast enhanced computed tomography (CT) images, provie custom workflows and UI, and reporting functions for nodule analysis including boundary detection of nodules based on the location specified by the user, measurement of nodules, temporal comparison of nodule images, and fusion of a CT nodule image on a PT nodule image.

> use positron emission tomography (PT) images, provide wustom workflows and UI, and reporting functions for nodule analysis including SLWV measurement of nodules with sphere VOl based on the location specified by the user, temporal comparison of nodule images, and fuision of a PT nodule image on a CT nodule image.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K120679: Synapse 3D Nodule Analysis.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K120679

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026