510(k) Report

510(k) · Cleared

Cleared

Advantage Windows Tissue Volume Option

K963345510(k) TraditionalCleared Oct 18, 199653-day reviewClass II21 CFR 892.1000

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

GE Medical Systems · LNH System, Nuclear Magnetic Resonance Imaging

Cleared on Oct 18, 1996 as substantially equivalent to K913770 (General Electric Co., 1991) after a 53-day review. Its family tree reaches back 1 generation to 1991. 1 of the 474 devices in its family, counting itself, has a Class I recall. 472 later devices descend from it.

Decided
Oct 18, 1996
Review
53 days
Class
Class II
Product code
LNH
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K913770 (1991). 472 later devices descend from it, 3 citing it directly. 1 of the 474 devices in this family, counting this one, has a Class I recall.

Descendants, by year cleared 2001: 2 descendants cleared2007: 12 descendants cleared2004: 9 descendants cleared2003: 4 descendants cleared2002: 1 descendant cleared2012: 23 descendants cleared2014: 19 descendants cleared2010: 9 descendants cleared2011: 11 descendants cleared2009: 10 descendants cleared2006: 8 descendants cleared2021: 25 descendants cleared2015: 20 descendants cleared2016: 16 descendants cleared2019: 22 descendants cleared2023: 33 descendants cleared2005: 2 descendants cleared2013: 11 descendants cleared2024: 35 descendants cleared2020: 31 descendants cleared2018: 27 descendants cleared2017: 21 descendants cleared2025: 44 descendants cleared, 1 with a Class I recall12022: 34 descendants cleared2026: 38 descendants cleared2008: 5 descendants clearedK913770 · Advantage V.S. CT/MR Rad Diagnostic Workstation · General Electric Co. · 19911990200020102020
Descendants, by generation 1 generation forward: 3 descendants2 generations forward: 14 descendants3 generations forward: 36 descendants4 generations forward: 61 descendants5 generations forward: 59 descendants6 generations forward: 73 descendants7 generations forward: 70 descendants, 1 with a Class I recall18 generations forward: 63 descendants9 generations forward: 44 descendants10 generations forward: 24 descendants11 generations forward: 14 descendants12 generations forward: 8 descendants13 generations forward: 3 descendants K913770 · Advantage V.S. CT/MR Rad Diagnostic Workstation · General Electric Co. · 19910+5+10
  1. Root · 1 generation backK913770 Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co. · 1991
  2. This deviceK963345 Advantage Windows Tissue Volume OptionGE Medical Systems · 1996
  3. Descendant · cites it directly · 470 of its ownK013381 Advanced Lung Analysis-1General Electric Co. · 2001
  4. Descendant · 2 generations on · 379 of its ownK022013 Lungcare CT Software PackageSiemens Medical Solutions USA, Inc. · 2002
  5. Descendant · 3 generations on · 295 of its ownK033374 Lungcare CT Software Package with Extended FunctionalitySiemens AG Medical Solutions · 2003
  6. Descendant · 3 generations on · 263 of its ownK063762 Syngo Circulation Software Package with Extended FunctionalitySiemens AG Medical Solutions · 2007
  7. Descendant · 4 generations on · 222 of its ownK041484 UndecidedSiemens Medical Solutions USA, Inc. · 2004

Showing 5 of 472 descendants. See all descendants

Descendants cleared per year

2001: 22002: 12003: 42004: 92005: 22006: 82007: 122008: 52009: 102010: 92011: 112012: 232013: 112014: 192015: 202016: 162017: 212018: 272019: 222020: 312021: 252022: 342023: 332024: 352025: 442026: 38
2001high 44 (2025) · low 1 (2002)2026

Class I recalls in this family

Most influential descendants

Showing 5 of 472 · See all
  • K013381Advanced Lung Analysis-1General Electric Co. · 2001 · cites it directly470descendants
  • K022013Lungcare CT Software PackageSiemens Medical Solutions USA, Inc. · 2002 · 2 generations on379descendants
  • K033374Lungcare CT Software Package with Extended FunctionalitySiemens AG Medical Solutions · 2003 · 3 generations on295descendants
  • K063762Syngo Circulation Software Package with Extended FunctionalitySiemens AG Medical Solutions · 2007 · 3 generations on263descendants
  • K041484UndecidedSiemens Medical Solutions USA, Inc. · 2004 · 4 generations on222descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K913770Advantage V.S. CT/MR Rad Diagnostic WorkstationGeneral Electric Co.1991—
0 (this device)K963345Advantage Windows Tissue Volume OptionGE Medical Systems1996—
+1K013381Advanced Lung Analysis-1General Electric Co.2001—
+2K022013Lungcare CT Software PackageSiemens Medical Solutions USA, Inc.2002—
+3K033374Lungcare CT Software Package with Extended FunctionalitySiemens AG Medical Solutions2003—
+3K063762Syngo Circulation Software Package with Extended FunctionalitySiemens AG Medical Solutions2007—
+4K041484UndecidedSiemens Medical Solutions USA, Inc.2004—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
200120
200210
200340
200490
200520
200680
2007120
200850
2009100
201090
2011110
2012230
2013110
2014190
2015200
2016160
2017210
2018270
2019220
2020310
2021250
2022340
2023330
2024350
2025441
2026380
FIG. 1 — Lineage of K963345, 1991–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LNH device

  1. #1 K213693 MAGNETOM Vida with syngo MR XA50Ascore 23.0 · 18 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K913770Advantage V.S. CT/MR Rad Diagnostic Workstation
Summary page 1
…ulate the volume of any three dimensional structure from a set of CT images. The images are displayed and measured on the CT/MR Advantage Windows Diagnostic Workstation (K913770). The Tissue Volume Option will automate manual measurements and estimates that are currently made regarding the measure of volum…
General Electric Co.1991—

Also cleared against K913770: 3 other devices →

What descends from it? (472)

See all 472

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K013381Advanced Lung Analysis-1General Electric Co.2001470
K071310Syngo CT Oncology Software PackageSiemens AG2007195
K012563Deep GrayCortechs Labs, Inc.20010

Has anything in its family been recalled? (1 Class I)

No FDA recall names this device.

Relatives with a Class I recall

Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.

  • K250443MAGNETOM Avanto Fit; MAGNETOM Skyra Fit; MAGNETOM Sola Fit; MAGNETOM Viato.MobileSiemens Healthcare GmbH · 2025 · 7 generations on · ◆ in the 2025 descendants bar of FIG. 12 Class I recalls

What does this lineage say?

  • Its one ancestor has no recall.
  • Of its descendants, K013381 (General Electric Co., 2001) has gone furthest, with 470 descendants of its own.
  • 3 other devices also cite its predicate K913770.

How does its category compare?

All LNH devices

LNH System, Nuclear Magnetic Resonance Imaging: FDA decisions, review times, recalls and adverse event reports over 20 years.

FDA decisions per year · LNH

26in 2025

2007: 122008: 192009: 172010: 122011: 162012: 222013: 192014: 172015: 192016: 202017: 182018: 292019: 262020: 322021: 272022: 302023: 302024: 262025: 262026 (partial year): 24
2007high 32 (2020) · low 12 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LNH

122in 2025

2007: 35 days median2008: 53 days median2009: 70 days median2010: 94 days median2011: 81 days median2012: 89 days median2013: 108 days median2014: 108 days median2015: 140 days median2016: 108 days median2017: 98 days median2018: 128 days median2019: 62 days median2020: 121 days median2021: 87 days median2022: 74 days median2023: 124 days median2024: 104 days median2025: 122 days median2026 (partial year): 126 days median
2007high 140 (2015) · low 35 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LNH

8in 2025

2007: 252008: 122009: 72010: 172011: 112012: 52013: 22014: 132015: 12, 2 Class I2016: 12018: 712019: 52020: 42021: 412022: 132023: 10, 1 Class I2024: 42025: 8, 5 Class I2026 (partial year): 43
2007high 71 (2018) · low 0 (2017)2026

Class I (8 since 2007) Class II/III not classified

Adverse event reports per year · LNH

1,263in 2025

2007: 1142008: 1672009: 1942010: 1652011: 1822012: 1702013: 1072014: 1192015: 1132016: 1352017: 1212018: 1582019: 1582020: 982021: 842022: 1382023: 1592024: 2812025: 1,263
2007high 1,263 (2025) · low 84 (2021)2025

MAUDE reports naming product code LNH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007123525114
2008195312167
200917707194
2010129417165
2011168111182
201222895170
2013191082107
20141710813119
20151914012 (2)113
2016201081135
201718980121
20182912871158
201926625158
202032121498
202127874184
2022307413138
20233012410 (1)159
2024261044281
2025261228 (5)1,263
20262412643—

What is it indicated for?

Advantage Windows Tisue Volume Option is intended to calculate the volume of any three dimensional structure from a set of CT images. The images are displayed and measured on the CT/MR Advantage Windows Diagnostic Workstation (K913770). The Tissue Volume Option will automate manual measurements and estimates that are currently made regarding the measure of volume of anatomy and pathology imaged with computed tomography.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K963345: Advantage Windows Tissue Volume Option.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K963345

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026