510(k) Report

510(k) · Cleared

Cleared

Medcomp Vascu-Picc & Midline Catheters

K121094510(k) SpecialCleared Jun 6, 201257-day reviewClass II21 CFR 880.5970

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Medical Components, Inc. · LJS Catheter, Intravascular, Therapeutic, Long-Term Greater Than 30 Days

Cleared on Jun 6, 2012 after a 57-day review. FDA’s file for it is a 510(k) statement, which names no predicate. 12 later devices descend from it.

Decided
Jun 6, 2012
Review
57 days
Class
Class II
Product code
LJS
Recalls
None
Predicates
0

12 later devices descend from it, 4 citing it directly.

Descendants, by year cleared 2014: 1 descendant cleared2012: 1 descendant cleared2013: 2 descendants cleared2016: 2 descendants cleared2017: 2 descendants cleared2018: 2 descendants cleared2022: 1 descendant cleared2019: 1 descendant cleared2010201520202025
  1. This deviceK121094 Medcomp Vascu-Picc & Midline CathetersMedical Components, Inc. · 2012
  2. Descendant · cites it directly · 8 of its ownK141151 CT MidlineMedcomp (Medical Components, Inc.) · 2014
  3. Descendant · 2 generations on · 5 of its ownK153393 PowerMidline CatheterC.R. Bard, Inc. · 2016 · Recalled
  4. Descendant · 3 generations on · 1 of its ownK173114 primeMidline CathetersPfm Medical, Inc. · 2018
  5. Descendant · 3 generations on · 1 of its ownK162900 PowerMidline CatheterC.R. Bard, Inc. · 2016 · Recalled
  6. Descendant · 4 generations on · 0 of its ownK213203 Provena (TM) Midline CatheterC.R. Bard, Inc. · 2022 · Recalled

Showing 5 of 12 descendants. See all descendants

Descendants cleared per year

2012: 12013: 22014: 12016: 22017: 22018: 22019: 12022: 1
2012high 2 (2013) · low 0 (2015)2026

Most influential descendants

Showing 5 of 12 · See all
  • K141151CT MidlineMedcomp (Medical Components, Inc.) · 2014 · cites it directly8descendants
  • K153393PowerMidline CatheterC.R. Bard, Inc. · 2016 · 2 generations on5descendants
  • K173114primeMidline CathetersPfm Medical, Inc. · 2018 · 3 generations on1descendant
  • K162900PowerMidline CatheterC.R. Bard, Inc. · 2016 · 3 generations on1descendant
  • K213203Provena (TM) Midline CatheterC.R. Bard, Inc. · 2022 · 4 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
0 (this device)K121094Medcomp Vascu-Picc & Midline CathetersMedical Components, Inc.2012—
+1K141151CT MidlineMedcomp (Medical Components, Inc.)2014—
+2K153393PowerMidline CatheterC.R. Bard, Inc.20161
+3K173114primeMidline CathetersPfm Medical, Inc.2018—
+3K162900PowerMidline CatheterC.R. Bard, Inc.20163
+4K213203Provena (TM) Midline CatheterC.R. Bard, Inc.20221

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201210
201320
201410
201620
201720
201820
201910
202210
FIG. 1 — Lineage of K121094, 2012–2022Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LJS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LJS device

  1. #1 K241910 Neonav ECG Tip Location Systemscore 18.0 · 12 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against?

FDA’s file for it is a 510(k) statement, which names no predicate.

What descends from it? (12)

See all 12

4 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K141151CT MidlineMedcomp (Medical Components, Inc.)20148
K130897Medcomp Vascu-Picc with ValveMedcomp ( Medical Components)20130
K1316876F X 60CM Triple Pro-Line CT Basic IR SetMedical Components, Inc.20130
K122423Vasu-PiccMedical Components, Inc.20120

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Of its descendants, K141151 (Medcomp (Medical Components, Inc.), 2014) has gone furthest, with 8 descendants of its own.

How does its category compare?

All LJS devices

LJS Catheter, Intravascular, Therapeutic, Long-Term Greater Than 30 Days: FDA decisions, review times, recalls and adverse event reports over 20 years. 2012, this device’s year, is highlighted.

FDA decisions per year · LJS

8in 2025

2007: 142008: 42009: 162010: 92011: 62012: 142013: 142014: 82015: 72016: 92017: 72018: 102020: 22021: 32022: 32023: 42024: 12025: 82026 (partial year): 2
2007high 16 (2009) · low 0 (2019)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LJS

171in 2025

2007: 92 days median2008: 97 days median2009: 70 days median2010: 114 days median2011: 55 days median2012: 77 days median2013: 31 days median2014: 47 days median2015: 71 days median2016: 128 days median2017: 101 days median2018: 148 days median2021: 284 days median2022: 177 days median2023: 47 days median2025: 171 days median
2007high 284 (2021) · low 31 (2013)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LJS

5in 2023

2008: 12009: 12010: 122011: 42012: 402014: 152015: 22016: 182017: 92018: 32021: 12023: 5, 2 Class I2026 (partial year): 8, 1 Class I
2007high 40 (2012) · low 0 (2007)2026

Class I (3 since 2007) Class II/III not classified

Adverse event reports per year · LJS

4,372in 2025

2007: 3922008: 3692009: 3792010: 4952011: 6962012: 5642013: 6802014: 8422015: 1,3062016: 1,1232017: 2,1002018: 2,3242019: 2,0522020: 2,5392021: 3,0842022: 3,2562023: 2,7992024: 4,2432025: 4,372
2007high 4,372 (2025) · low 369 (2008)2025

MAUDE reports naming product code LJS, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200714920392
20084971369
200916701379
2010911412495
20116554696
2012147740564
201314310680
201484715842
201577121,306
20169128181,123
2017710192,100
20181014832,324
20190—02,052
20202—02,539
2021328413,084
2022317703,256
20234475 (2)2,799
20241—04,243
2025817104,372
20262—8 (1)—

What is it indicated for?

The Peripherally Inserted Central Vein Access catheters are designed for short or long term peripheral access to the central venous system for intravenous therapy and blood sampling, For central venous pressure monitoring (CVP), it is recommended that catheter lumen of 20 gauge or larger be used.

The Mdline catheters are indicated for shaft or long term peripheral access to the peripheral veious system for selected intravenous therapies and blood sampling. (See Confraindications). For blood therapy it is recommended that a 4F7rench or larger catheter be used.

Indications for use as stated in the FDA 510(k) statement.

Cite this page

510(k) Report. “K121094: Medcomp Vascu-Picc & Midline Catheters.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K121094

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026