510(k) Report

510(k) · Cleared

Recalled · Class II · 2014

Immunocap Allergen K82

K121463510(k) TraditionalCleared Jan 29, 2013257-day reviewClass II21 CFR 866.5750Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Thermo Fisher Scientific · DHB System, Test, Radioallergosorbent (Rast) Immunological

Cleared on Jan 29, 2013 as substantially equivalent to K972068 (Pharmacia, Inc., 1997) after a 257-day review. Its family tree reaches back 3 generations to 1995. It has been recalled once.

Decided
Jan 29, 2013
Review
257 days
Class
Class II
Product code
DHB
Recalls
1
Predicates
1

Its longest line of descent runs back 3 generations to K953014 (1995). No later device cites it as a predicate yet.

  1. Root · 3 generations backK953014 Alastat Microplate Latex-Specific Ige AllergenDiagnostic Products Corp. · 1995
  2. 2 generations backK962976 Pharmacia Cap System Rast FeiaPharmacia & Upjohn Co. · 1996
  3. 1 generation backK972068 Unicap Specific Ige Feia Assay, Latex Allergen Immunocap K82Pharmacia, Inc. · 1997
  4. This deviceK121463 Immunocap Allergen K82Thermo Fisher Scientific · 2013
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K953014Alastat Microplate Latex-Specific Ige AllergenDiagnostic Products Corp.1995—
−2K962976Pharmacia Cap System Rast FeiaPharmacia & Upjohn Co.1996—
−1K972068Unicap Specific Ige Feia Assay, Latex Allergen Immunocap K82Pharmacia, Inc.1997—
0 (this device)K121463Immunocap Allergen K82Thermo Fisher Scientific2013—
FIG. 1 — Lineage of K121463, 1995–2013Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DHB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DHB device

  1. #1 K260331 IMMULITE 2000 3gAllergy Specific IgE Vantage…score 12.3 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K972068Unicap Specific Ige Feia Assay, Latex Allergen Immunocap K82
Summary page 1
…DHB Class 11 CFR 866.5750 Substantial Equivalence to: .ImmunoCAP Allergen k82, Latex (Art. No. 14-4345-01), K972068 Thermo Fsher 2(2) S C IEN T IF IC…
Pharmacia, Inc.1997—

Also cleared against K972068: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Nov 20, 2014Class IIZ-0947-2015Software designDuring an investigation of instrument logs it was determined that In specific circumstances involving multiple steps, a rack sequencing error may occur. This will result in a mismatch between the sample ID and the test result reported for…

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 18 years and passes through 4 companies; a new generation was cleared every 1.4 years on median.
  • None of the 3 ancestors has a recall.
  • 1 other device also cites its predicate K972068.

How does its category compare?

All DHB devices

DHB System, Test, Radioallergosorbent (Rast) Immunological: FDA decisions, review times, recalls and adverse event reports over 20 years. 2013, this device’s year, is highlighted.

FDA decisions per year · DHB

2in 2025

2007: 12008: 22009: 72010: 32011: 52012: 32013: 52014: 12015: 12016: 22017: 12018: 22019: 32020: 22021: 12022: 22025: 22026 (partial year): 6
2007high 7 (2009) · low 0 (2023)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DHB

90in 2019

2009: 118 days median2010: 247 days median2011: 405 days median2012: 260 days median2013: 257 days median2019: 90 days median2026 (partial year): 138 days median
2007high 405 (2011) · low 90 (2019)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DHB

14in 2025

2012: 12014: 12017: 12018: 12022: 32025: 14
2007high 14 (2025) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DHB

6in 2025

2008: 12011: 12012: 22015: 12017: 112018: 62019: 42021: 72022: 12023: 62024: 102025: 6
2007high 11 (2017) · low 0 (2007)2025

MAUDE reports naming product code DHB, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—00
20082—01
2009711800
2010324700
2011540501
2012326012
2013525700
20141—10
20151—01
20162—00
20171—111
20182—16
201939004
20202—00
20211—07
20222—31
20230—06
20240—010
20252—146
202661380—

What is it indicated for?

ImmunoCAP Specific IgE is an in vitro quantitative assay for the measurement of allergen specific IgE in human serum or plasma (EDTA or Na-Heparin). ImmunoCAP Specific IgE is to be used with instruments Phadia 100, Phadia 250, Phadia 1000, Phadia 2500 and Phadia 5000. It is intended for in vitro diagnostic use as an aid in the clinical diagnosis of IgE mediated allergic disorders in conjunction with other clinical findings, and is to be used in clinical laboratories.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K121463: Immunocap Allergen K82.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K121463

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026