510(k) · Cleared
ClearedTowerlox Pedicle Screw System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Captiva Spine · MNI Orthosis, Spinal Pedicle Fixation
Cleared on Oct 16, 2012 as substantially equivalent to K111115 (Captiva Spine, Inc., 2011) and 6 other predicates after a 75-day review. Its family tree reaches back 13 generations to 2004. 14 later devices descend from it.
- Decided
- Oct 16, 2012
- Review
- 75 days
- Class
- Class II
- Product code
- MNI
- Recalls
- None
- Predicates
- 7
Its longest line of descent runs back 13 generations to K040583 (2004). 141 ancestors in all, the oldest K841189 (1984). 14 later devices descend from it, 3 citing it directly.
- Root · 13 generations backK040583 Modification to: CD Horizon Spinal SystemMedtronic Sofamor Danek · 2004
- 9 generations between
- 3 generations backK112473 CD Horizon Spinal SystemMedtronic Sofamor Danek, Inc. · 2011
- 2 generations backK113174 CD Horizon Spinal SystemMedtronic Sofamor Danek USA, Inc. · 2011 · Recalled
- 1 generation backK121680 CD Horizon Spinal SystemMedtronic Sofamor Danek USA, Inc. · 2012
- This deviceK122332 Towerlox Pedicle Screw SystemCaptiva Spine · 2012
- Descendant · cites it directly · 6 of its ownK131538 Caplox II Pedicle Screw System/Towerlox Pedicle Screw SystemCaptiva Spine · 2013
- Descendant · cites it directly · 5 of its ownK152781 Adena-Zina SystemShanghai Sanyou Medical Co, Ltd. · 2016
- Descendant · 2 generations on · 3 of its ownK212066 Adena-Zina SystemShanghai Sanyou Medical Co, Ltd. · 2021
- Descendant · 2 generations on · 3 of its ownK151116 CapLOX II/TowerLOX Pedicle Screw SystemCaptiva Spine · 2015
- Descendant · 2 generations on · 2 of its ownK230961 Zeus Spinal SystemShanghai Sanyou Medical Co, Ltd. · 2023
Show all 13 generations
- Root · 13 generations backK040583 Modification to: CD Horizon Spinal SystemMedtronic Sofamor Danek · 2004
- 12 generations backK041118 Modification to CD Horizon Spinal SystemMedtronic Sofamor Danek · 2004
- 11 generations backK042025 Modification to CD Horizon Spinal SystemMedtronic Sofamor Danek, Inc. · 2004 · Recalled
- 10 generations backK043151 Modification to: CD Horizon Spinal SystemMedtronic Sofamor Danek · 2005
- 9 generations backK050809 CD Horizon Spinal SystemMedtronic Sofamor Danek USA, Inc. · 2005
- 8 generations backK052187 Modification to: CD Horizon Spinal SystemMedtronic Sofamor Danek · 2005
- 7 generations backK053101 CD Horizon Spinal SystemMedtronic Sofamor Danek · 2006
- 6 generations backK091442 CD Horizon Spinal SystemMedtronic Sofamor Danek · 2009
- 5 generations backK091974 Modification to CD Horizon Spinal SystemMedtronic Sofamor Danek USA, Inc. · 2009 · Recalled
- 4 generations backK102555 CD Horizon Spinal SystemMedtronic Sofamor Danek USA, Inc. · 2010
- 3 generations backK112473 CD Horizon Spinal SystemMedtronic Sofamor Danek, Inc. · 2011
- 2 generations backK113174 CD Horizon Spinal SystemMedtronic Sofamor Danek USA, Inc. · 2011 · Recalled
- 1 generation backK121680 CD Horizon Spinal SystemMedtronic Sofamor Danek USA, Inc. · 2012
- This deviceK122332 Towerlox Pedicle Screw SystemCaptiva Spine · 2012
Showing 5 of 14 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 14 · See all- K131538Caplox II Pedicle Screw System/Towerlox Pedicle Screw SystemCaptiva Spine · 2013 · cites it directly6descendants
- K152781Adena-Zina SystemShanghai Sanyou Medical Co, Ltd. · 2016 · cites it directly5descendants
- K212066Adena-Zina SystemShanghai Sanyou Medical Co, Ltd. · 2021 · 2 generations on3descendants
- K151116CapLOX II/TowerLOX Pedicle Screw SystemCaptiva Spine · 2015 · 2 generations on3descendants
- K230961Zeus Spinal SystemShanghai Sanyou Medical Co, Ltd. · 2023 · 2 generations on2descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −13 | K040583 | Modification to: CD Horizon Spinal System | Medtronic Sofamor Danek | 2004 | — |
| −12 | K041118 | Modification to CD Horizon Spinal System | Medtronic Sofamor Danek | 2004 | — |
| −11 | K042025 | Modification to CD Horizon Spinal System | Medtronic Sofamor Danek, Inc. | 2004 | 4 |
| −10 | K043151 | Modification to: CD Horizon Spinal System | Medtronic Sofamor Danek | 2005 | — |
| −9 | K050809 | CD Horizon Spinal System | Medtronic Sofamor Danek USA, Inc. | 2005 | — |
| −8 | K052187 | Modification to: CD Horizon Spinal System | Medtronic Sofamor Danek | 2005 | — |
| −7 | K053101 | CD Horizon Spinal System | Medtronic Sofamor Danek | 2006 | — |
| −6 | K091442 | CD Horizon Spinal System | Medtronic Sofamor Danek | 2009 | — |
| −5 | K091974 | Modification to CD Horizon Spinal System | Medtronic Sofamor Danek USA, Inc. | 2009 | 1 |
| −4 | K102555 | CD Horizon Spinal System | Medtronic Sofamor Danek USA, Inc. | 2010 | — |
| −3 | K112473 | CD Horizon Spinal System | Medtronic Sofamor Danek, Inc. | 2011 | — |
| −2 | K113174 | CD Horizon Spinal System | Medtronic Sofamor Danek USA, Inc. | 2011 | 1 |
| −1 | K121680 | CD Horizon Spinal System | Medtronic Sofamor Danek USA, Inc. | 2012 | — |
| 0 (this device) | K122332 | Towerlox Pedicle Screw System | Captiva Spine | 2012 | — |
| +1 | K131538 | Caplox II Pedicle Screw System/Towerlox Pedicle Screw System | Captiva Spine | 2013 | — |
| +1 | K152781 | Adena-Zina System | Shanghai Sanyou Medical Co, Ltd. | 2016 | — |
| +2 | K212066 | Adena-Zina System | Shanghai Sanyou Medical Co, Ltd. | 2021 | — |
| +2 | K151116 | CapLOX II/TowerLOX Pedicle Screw System | Captiva Spine | 2015 | — |
| +2 | K230961 | Zeus Spinal System | Shanghai Sanyou Medical Co, Ltd. | 2023 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1984 | 1 | 0 |
| 1990 | 2 | 0 |
| 1992 | 5 | 0 |
| 1993 | 2 | 0 |
| 1994 | 1 | 0 |
| 1995 | 3 | 0 |
| 1996 | 5 | 0 |
| 1997 | 2 | 0 |
| 1998 | 6 | 0 |
| 1999 | 3 | 0 |
| 2000 | 9 | 0 |
| 2001 | 7 | 0 |
| 2002 | 7 | 0 |
| 2003 | 8 | 0 |
| 2004 | 21 | 0 |
| 2005 | 14 | 0 |
| 2006 | 8 | 0 |
| 2007 | 5 | 0 |
| 2008 | 5 | 0 |
| 2009 | 6 | 0 |
| 2010 | 4 | 0 |
| 2011 | 3 | 0 |
| 2012 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2013 | 1 | 0 |
| 2015 | 1 | 0 |
| 2016 | 3 | 0 |
| 2018 | 3 | 0 |
| 2020 | 1 | 0 |
| 2021 | 1 | 0 |
| 2023 | 2 | 0 |
| 2024 | 1 | 0 |
| 2025 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in MNI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
- Candidate predicates for a device like this, rankedin the report
- Recall history across each candidate’s familyin the report
What was it cleared against? (7)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K111115 | Captiva Spine Caplox II Spinal Fixation System | 2011 |
| * | K120292 | Caplox II Pedicle Screw SystemSummary page 1…MNI, MNhH Panel Code: 87 Predicate Device(s): CapLOX II Pedicle Screw System (Ki 11115, SE 9-13-1 1), (K 120292, SE 4-13 -12) Laguna Pedicle Screw System (K103748, SE 3-2-11) Denali… | 2012 |
| * | K103748 | Laguna Pedicle Screw SystemSummary page 1…CapLOX II Pedicle Screw System (Ki 11115, SE 9-13-1 1), (K 120292, SE 4-13 -12) Laguna Pedicle Screw System (K103748, SE 3-2-11) Denali Spinal System (K042635, SE 1-10-05) Spherx Pedicle… | 2011 |
| * | K042635 | Denali Spine SystemSummary page 1…(K 120292, SE 4-13 -12) Laguna Pedicle Screw System (K103748, SE 3-2-11) Denali Spinal System (K042635, SE 1-10-05) Spherx Pedicle Screw System (K092287, SE 10-6-09) Sextan… | 2005 |
| * | K092287 | Nuvasive Spherx II - Pedicle Screw SystemSummary page 1…cle Screw System (K103748, SE 3-2-11) Denali Spinal System (K042635, SE 1-10-05) Spherx Pedicle Screw System (K092287, SE 10-6-09) Sextant/CD Horizon MIS System (K121680, SE 7-5-12) Array… | 2009 |
| * | K121680 | CD Horizon Spinal SystemSummary page 1…System (K042635, SE 1-10-05) Spherx Pedicle Screw System (K092287, SE 10-6-09) Sextant/CD Horizon MIS System (K121680, SE 7-5-12) Array Spinal System (K061978, SE 8-11-06) Reason for this Submission: This Special 5 1… | 2012 |
| * | K061978 | Ebi, L.P.'S Line Extension to the Array Spinal SystemSummary page 1…le Screw System (K092287, SE 10-6-09) Sextant/CD Horizon MIS System (K121680, SE 7-5-12) Array Spinal System (K061978, SE 8-11-06) Reason for this Submission: This Special 5 10(k) involves several changes to the previously cleared CapLOX 11 Syste… | 2006 |
What descends from it? (14)
See all 143 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 8 years and passes through 4 companies; a new generation was cleared every 4 months on median.
- 18 of the 141 ancestors have a recall of any class.
- Of its descendants, K131538 (Captiva Spine, 2013) has gone furthest, with 6 descendants of its own.
- 1 other device also cites its predicate K111115.
How does its category compare?
All MNI devicesMNI Orthosis, Spinal Pedicle Fixation: FDA decisions, review times, recalls and adverse event reports over 20 years. 2012, this device’s year, is highlighted.
FDA decisions per year · MNI
1in 2017
2026 to Oct 25, outlined.
Median 510(k) review, days · MNI
168in 2016
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · MNI
1in 2018
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · MNI
80in 2025
MAUDE reports naming product code MNI, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 20 | 82 | 26 | 83 |
| 2008 | 23 | 64 | 8 | 108 |
| 2009 | 18 | 86 | 3 | 138 |
| 2010 | 16 | 74 | 1 | 126 |
| 2011 | 17 | 111 | 0 | 146 |
| 2012 | 19 | 75 | 1 | 200 |
| 2013 | 14 | 77 | 4 | 824 |
| 2014 | 6 | 104 | 0 | 301 |
| 2015 | 12 | 54 | 1 | 260 |
| 2016 | 7 | 168 | 0 | 117 |
| 2017 | 1 | — | 0 | 247 |
| 2018 | 0 | — | 1 | 134 |
| 2019 | 0 | — | 0 | 188 |
| 2020 | 0 | — | 0 | 115 |
| 2021 | 0 | — | 0 | 270 |
| 2022 | 0 | — | 0 | 214 |
| 2023 | 0 | — | 0 | 122 |
| 2024 | 0 | — | 0 | 114 |
| 2025 | 0 | — | 0 | 80 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
The TowerLOX Spinal System is a posterior, non-cervical pedicle fixation system intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar and sacral spine including degenerative spondylolisthesis with objective evidence of neurologic impairment, fracture, dislocation, scoliosis…
Read the full statement (144 words)
The TowerLOX Spinal System is a posterior, non-cervical pedicle fixation system intended to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion in the treatment of the following acute and chronic instabilities or deformities of the thoracic, lumbar and sacral spine including degenerative spondylolisthesis with objective evidence of neurologic impairment, fracture, dislocation, scoliosis, kyphosis, spinal tumor, pseudoarthrosis and failed previous fusion.
In addition, when used as a pedicle screw fixation system, the TowerLOX Spinal System is intended for skeletally mature patients with severe spondylolisthesis (Grades 3 and 4) of the fifth lumbar-first sacral, L5-S1 vertebra, who are receiving fusion by autogenous bone graft only, who are having the device attached to the lumbar and sacral spine (levels may be from L3 to the sacrum/ilium), who are having the device removed after the attainment of a solid fusion.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K122332 · printed Nov 6, 2026
Cite this page
510(k) Report. “K122332: Towerlox Pedicle Screw System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K122332
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026