510(k) · Cleared
ClearedAdena-Zina System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Shanghai Sanyou Medical Co, Ltd. · NKB Thoracolumbosacral Pedicle Screw System
Cleared on Aug 16, 2021 as substantially equivalent to K152781 (Shanghai Sanyou Medical Co, Ltd., 2016) and 1 other predicate after a 45-day review. Its family tree reaches back 15 generations to 1985. 1 of the 256 devices in its family, counting itself, has a Class I recall. 3 later devices descend from it.
- Decided
- Aug 16, 2021
- Review
- 45 days
- Class
- Class II
- Product code
- NKB
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 15 generations to K853033 (1985). 252 ancestors in all, the oldest K781443 (1978). 3 later devices descend from it, 1 citing it directly. 1 of the 256 devices in this family, counting this one, has a Class I recall.
- Root · 15 generations backK853033 Hartshill Rect & Wires, Spinal Fixation SystemA.W. Showell (Surgicraft), Ltd. · 1985
- 11 generations between
- 3 generations backK101070 Expedium Spine SystemMedos International SARL · 2010 · Recalled
- 2 generations backK122226 Revere Stabilization SystemGlobus Medical, Inc. · 2012
- 1 generation backK124058 Creo Stabilization SystemGlobus Medical, Inc. · 2013
- This deviceK212066 Adena-Zina SystemShanghai Sanyou Medical Co, Ltd. · 2021
- Descendant · cites it directly · 2 of its ownK230961 Zeus Spinal SystemShanghai Sanyou Medical Co, Ltd. · 2023
- Descendant · 2 generations on · 1 of its ownK240392 JAZZ Spinal SystemImplanet · 2024
- Descendant · 2 generations on · 0 of its ownK252437 JAZZ Spinal SystemImplanet · 2025
Show all 15 generations
- Root · 15 generations backK853033 Hartshill Rect & Wires, Spinal Fixation SystemA.W. Showell (Surgicraft), Ltd. · 1985
- 14 generations backK965221 Ransford Cervical Fixation SystemSurgicraft, Ltd. · 1997
- 13 generations backK982322 Synthes Spine Occipital-Cervical Plate/Rod and Hook SystemSynthes (Usa) · 1998
- 12 generations backK002733 Summit Occipito-Cervico-Thoracic (Oct) Spinal SystemDepuyacromed · 2000
- 11 generations backK013222 Summit Occipito-Cervico- Thoracic (Oct) Spinal SystemDepuyacromed · 2001
- 10 generations backK022190 Modification to Summit Occipito-Cervico-Thoracic (Oct) Spinal SystemDepuyacromed · 2002
- 9 generations backK030103 Summit Oct Spinal System Minipolyaxial ScrewsDepuyacromed · 2003
- 8 generations backK041203 Summit Oct Spinal SystemDepuy Spine, Inc. · 2004
- 7 generations backK062174 Modification to Expedium Spine SystemDepuy Spine, Inc. · 2006
- 6 generations backK063156 Modification to Expedium Spine SystemDepuy Spine, Inc. · 2006
- 5 generations backK063741 Expedium Spine SystemDepuy Spine, Inc. · 2007
- 4 generations backK080313 Modification to Expedium Spine SystemDepuy Spine, Inc. · 2008
- 3 generations backK101070 Expedium Spine SystemMedos International SARL · 2010 · Recalled
- 2 generations backK122226 Revere Stabilization SystemGlobus Medical, Inc. · 2012
- 1 generation backK124058 Creo Stabilization SystemGlobus Medical, Inc. · 2013
- This deviceK212066 Adena-Zina SystemShanghai Sanyou Medical Co, Ltd. · 2021
Class I recalls in this family
- K100952 Modification to Synthes Matrix System2 generations back · 2010
Most influential descendants
Showing 3 of 3 · See allView FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −15 | K853033 | Hartshill Rect & Wires, Spinal Fixation System | A.W. Showell (Surgicraft), Ltd. | 1985 | — |
| −14 | K965221 | Ransford Cervical Fixation System | Surgicraft, Ltd. | 1997 | — |
| −13 | K982322 | Synthes Spine Occipital-Cervical Plate/Rod and Hook System | Synthes (Usa) | 1998 | — |
| −12 | K002733 | Summit Occipito-Cervico-Thoracic (Oct) Spinal System | Depuyacromed | 2000 | — |
| −11 | K013222 | Summit Occipito-Cervico- Thoracic (Oct) Spinal System | Depuyacromed | 2001 | — |
| −10 | K022190 | Modification to Summit Occipito-Cervico-Thoracic (Oct) Spinal System | Depuyacromed | 2002 | — |
| −9 | K030103 | Summit Oct Spinal System Minipolyaxial Screws | Depuyacromed | 2003 | — |
| −8 | K041203 | Summit Oct Spinal System | Depuy Spine, Inc. | 2004 | — |
| −7 | K062174 | Modification to Expedium Spine System | Depuy Spine, Inc. | 2006 | — |
| −6 | K063156 | Modification to Expedium Spine System | Depuy Spine, Inc. | 2006 | — |
| −5 | K063741 | Expedium Spine System | Depuy Spine, Inc. | 2007 | — |
| −4 | K080313 | Modification to Expedium Spine System | Depuy Spine, Inc. | 2008 | — |
| −3 | K101070 | Expedium Spine System | Medos International SARL | 2010 | 1 |
| −2 | K122226 | Revere Stabilization System | Globus Medical, Inc. | 2012 | — |
| −1 | K124058 | Creo Stabilization System | Globus Medical, Inc. | 2013 | — |
| 0 (this device) | K212066 | Adena-Zina System | Shanghai Sanyou Medical Co, Ltd. | 2021 | — |
| +1 | K230961 | Zeus Spinal System | Shanghai Sanyou Medical Co, Ltd. | 2023 | — |
| +2 | K240392 | JAZZ Spinal System | Implanet | 2024 | — |
| +2 | K252437 | JAZZ Spinal System | Implanet | 2025 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1978 | 1 | 0 |
| 1984 | 1 | 0 |
| 1990 | 2 | 0 |
| 1992 | 5 | 0 |
| 1993 | 3 | 0 |
| 1994 | 1 | 0 |
| 1995 | 6 | 0 |
| 1996 | 6 | 0 |
| 1997 | 5 | 0 |
| 1998 | 10 | 0 |
| 1999 | 10 | 0 |
| 2000 | 14 | 0 |
| 2001 | 18 | 0 |
| 2002 | 11 | 0 |
| 2003 | 14 | 0 |
| 2004 | 26 | 0 |
| 2005 | 25 | 0 |
| 2006 | 13 | 0 |
| 2007 | 11 | 0 |
| 2008 | 13 | 0 |
| 2009 | 16 | 0 |
| 2010 | 10 | 1 |
| 2011 | 9 | 0 |
| 2012 | 5 | 0 |
| 2013 | 1 | 0 |
| 2016 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2023 | 1 | 0 |
| 2024 | 1 | 0 |
| 2025 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
1 device in this family has a Class I recall. A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new NKB device
- #1 K223494 CD Horizon Spinal Systemscore 40.4 · 30 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K152781 | Adena-Zina SystemSummary page 4…pedicle screw system) Panel: Orthopedic Product Code: NKB Primary Predicate: Shanghai Sanyou Medical Co, LTD, Adena-Zina System (K152781) Additional Predicate: Globus Medical Inc., CREOTM Stabilization System (K124058)… | 2016 |
| * | K124058 | Creo Stabilization SystemSummary page 4…NKB Primary Predicate: Shanghai Sanyou Medical Co, LTD, Adena-Zina System (K152781) Additional Predicate: Globus Medical Inc., CREOTM Stabilization System (K124058) K212066… | 2013 |
What descends from it? (3)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K230961 | Zeus Spinal System | 2023 | 2 |
Has anything in its family been recalled? (1 Class I)
No FDA recall names this device.
Relatives with a Class I recall
Class I is FDA’s most serious recall class. A recall in the family tree is context for this device, not evidence about it.
- K100952Modification to Synthes Matrix SystemSynthes Spine · 2010 · 2 generations back · ◆ in the 2010 ancestors bar of FIG. 11 Class I recall
What does this lineage say?
- The line of descent spans 36 years and passes through 8 companies; a new generation was cleared every 1.3 years on median.
- 25 of the 252 ancestors have a recall of any class; 1 has a Class I recall.
- Of its descendants, K230961 (Shanghai Sanyou Medical Co, Ltd., 2023) has gone furthest, with 2 descendants of its own.
- 3 other devices also cite its predicate K152781.
How does its category compare?
All NKB devicesNKB Thoracolumbosacral Pedicle Screw System: FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.
FDA decisions per year · NKB
24in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · NKB
61in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · NKB
1in 2025
Class I (1 since 2007) Class II/III not classified
Adverse event reports per year · NKB
1,171in 2025
MAUDE reports naming product code NKB, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 38 | 87 | 4 | 34 |
| 2008 | 36 | 59 | 5 | 82 |
| 2009 | 44 | 71 | 33 | 171 |
| 2010 | 37 | 111 | 4 | 462 |
| 2011 | 48 | 84 | 3 | 577 |
| 2012 | 60 | 79 | 13 | 1,747 |
| 2013 | 35 | 73 | 0 | 1,962 |
| 2014 | 46 | 90 | 3 (1) | 1,671 |
| 2015 | 55 | 90 | 3 | 1,446 |
| 2016 | 50 | 84 | 1 | 1,585 |
| 2017 | 63 | 69 | 1 | 1,618 |
| 2018 | 56 | 61 | 3 | 1,684 |
| 2019 | 39 | 84 | 1 | 1,915 |
| 2020 | 48 | 68 | 1 | 2,076 |
| 2021 | 32 | 61 | 0 | 1,745 |
| 2022 | 34 | 88 | 5 | 1,339 |
| 2023 | 44 | 72 | 2 | 919 |
| 2024 | 39 | 57 | 3 | 1,614 |
| 2025 | 24 | 61 | 1 | 1,171 |
| 2026 | 30 | 91 | 3 | — |
What is it indicated for?
The Adena-Zina System is intended for posterior, non-cervical fixation as an adjunct to fusion for skeletally mature patients for the following indications: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies); spondylolisthesis; trauma (i.e., fracture or dislocation); spinal stenosis; curvatures (i.e., scoliosis, kyphosis and/or lordosis); tumor; pseudarthrosis…
Read the full statement (138 words)
The Adena-Zina System is intended for posterior, non-cervical fixation as an adjunct to fusion for skeletally mature patients for the following indications: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies); spondylolisthesis; trauma (i.e., fracture or dislocation); spinal stenosis; curvatures (i.e., scoliosis, kyphosis and/or lordosis); tumor; pseudarthrosis; and/or failed previous fusion.
In addition, when used as a pedicle screw fixation system, the Adena-Zina System is intended for skeletally mature patients with severe spondylolisthesis (Grades 3 and 4) of the fifth lumbar-first sacral, L5-S1 vertebra, who are receiving fusion by autogenous bone graft only, who are having the device attached to the lumbar and sacral spine (levels may be from L3 to the sacrum/ilium), who are having the device removed after the attainment of a solid fusion.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K212066 · printed Nov 5, 2026
Cite this page
510(k) Report. “K212066: Adena-Zina System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K212066
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026