510(k) · Cleared
ClearedGram Postitve Clindamycin
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
bioMerieux, Inc. · LON System, Test, Automated, Antimicrobial Susceptibility, Short Incubation
Cleared on Oct 15, 2012 as substantially equivalent to K032766 (bioMerieux, Inc., 2003) after a 55-day review. Its family tree reaches back 1 generation to 2003. 5 later devices descend from it.
- Decided
- Oct 15, 2012
- Review
- 55 days
- Class
- Class II
- Product code
- LON
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 1 generation to K032766 (2003). 5 later devices descend from it, 1 citing it directly.
- Root · 1 generation backK032766 Vitek 2 Gram Positive LinezolidbioMerieux, Inc. · 2003
- This deviceK122547 Gram Postitve ClindamycinbioMerieux, Inc. · 2012
- Descendant · cites it directly · 4 of its ownK141149 Vitek 2 Ast GP CeftarolinebioMerieux, Inc. · 2014
- Descendant · 2 generations on · 3 of its ownK190616 VITEK 2 AST-Gram Positive Dalbavancin (<= 0.015 - >= 1 µg/mL)bioMerieux, Inc. · 2019
- Descendant · 3 generations on · 0 of its ownK212243 VITEK 2 AST- Gram Positive Telavancin (<=0.015 - >=1 µg/mL)bioMerieux, Inc. · 2022
- Descendant · 3 generations on · 0 of its ownK202396 VITEK 2 AST-Gram Positive Fosfomycin (<=8 - >=256 ug/mL)bioMerieux, Inc. · 2021
- Descendant · 3 generations on · 0 of its ownK200590 VITEK 2 AST-Gram Positive Delafloxacin (<=0.015 - >=1 µg/mL)bioMerieux, Inc. · 2020
Most influential descendants
Showing 5 of 5 · See all- K141149Vitek 2 Ast GP CeftarolinebioMerieux, Inc. · 2014 · cites it directly4descendants
- K190616VITEK 2 AST-Gram Positive Dalbavancin (<= 0.015 - >= 1 µg/mL)bioMerieux, Inc. · 2019 · 2 generations on3descendants
- K212243VITEK 2 AST- Gram Positive Telavancin (<=0.015 - >=1 µg/mL)bioMerieux, Inc. · 2022 · 3 generations on0descendants
- K202396VITEK 2 AST-Gram Positive Fosfomycin (<=8 - >=256 ug/mL)bioMerieux, Inc. · 2021 · 3 generations on0descendants
- K200590VITEK 2 AST-Gram Positive Delafloxacin (<=0.015 - >=1 µg/mL)bioMerieux, Inc. · 2020 · 3 generations on0descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K032766 | Vitek 2 Gram Positive Linezolid | bioMerieux, Inc. | 2003 | — |
| 0 (this device) | K122547 | Gram Postitve Clindamycin | bioMerieux, Inc. | 2012 | — |
| +1 | K141149 | Vitek 2 Ast GP Ceftaroline | bioMerieux, Inc. | 2014 | — |
| +2 | K190616 | VITEK 2 AST-Gram Positive Dalbavancin (<= 0.015 - >= 1 µg/mL) | bioMerieux, Inc. | 2019 | — |
| +3 | K212243 | VITEK 2 AST- Gram Positive Telavancin (<=0.015 - >=1 µg/mL) | bioMerieux, Inc. | 2022 | — |
| +3 | K202396 | VITEK 2 AST-Gram Positive Fosfomycin (<=8 - >=256 ug/mL) | bioMerieux, Inc. | 2021 | — |
| +3 | K200590 | VITEK 2 AST-Gram Positive Delafloxacin (<=0.015 - >=1 µg/mL) | bioMerieux, Inc. | 2020 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2014 | 1 | 0 |
| 2019 | 1 | 0 |
| 2020 | 1 | 0 |
| 2021 | 1 | 0 |
| 2022 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in LON? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LON device
- #1 K260619 VITEK 2 AST-Streptococcus Cefepime (<=0.06 –…score 13.3 · 5 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K032766 | Vitek 2 Gram Positive LinezolidSummary page 1…t Code LON Common Name: VITEF& 2 AST - GP Clindamycin C. Predicate Device: VITEK®2 Gram Positive Linezolid (k032766) D. 510(k) Summary: VITEK 2 AST - Gram Positive Clindamycin is designed for an antimicrobial susceptibility testing of St… | 2003 |
| † | K050002 | Vitek 2 Compact | 2005 |
What descends from it? (5)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K141149 | Vitek 2 Ast GP Ceftaroline | 2014 | 4 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
How does its category compare?
All LON devicesLON System, Test, Automated, Antimicrobial Susceptibility, Short Incubation: FDA decisions, review times, recalls and adverse event reports over 20 years. 2012, this device’s year, is highlighted.
FDA decisions per year · LON
5in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · LON
90in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · LON
1in 2025
Class I (2 since 2007) Class II/III not classified
Adverse event reports per year · LON
690in 2025
MAUDE reports naming product code LON, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 19 | 50 | 0 | 3 |
| 2008 | 7 | 66 | 1 | 1 |
| 2009 | 8 | 76 | 0 | 0 |
| 2010 | 1 | — | 116 | 3 |
| 2011 | 8 | 85 | 3 | 4 |
| 2012 | 10 | 200 | 3 | 9 |
| 2013 | 7 | 115 | 0 | 3 |
| 2014 | 4 | 90 | 2 (2) | 10 |
| 2015 | 0 | — | 0 | 41 |
| 2016 | 3 | 242 | 2 | 94 |
| 2017 | 10 | 89 | 1 | 197 |
| 2018 | 4 | 88 | 6 | 512 |
| 2019 | 8 | 84 | 1 | 315 |
| 2020 | 5 | 81 | 8 | 218 |
| 2021 | 5 | 268 | 0 | 232 |
| 2022 | 8 | 189 | 15 | 180 |
| 2023 | 11 | 210 | 0 | 453 |
| 2024 | 2 | — | 1 | 418 |
| 2025 | 5 | 90 | 1 | 690 |
| 2026 | 4 | 146 | 6 | — |
What is it indicated for?
VITEK® 2 AST-GP Clindlamycin is designed for antimicrobial susceptibility testing of Staphylococcus aureus and Staphylococcus epiderniidis. VITEK 2 AST-GP Clindlamycin is a quantitative test intended for use with the VITEK® 2 and VITEK® 2 Compact Systems as a laboratory aid in the determination of in vitro susceptibility to antimicrobial agents. Clindamycin has been shown to be active against most strains of the microorganism listed below, according to…
Read the full statement (138 words)
VITEK® 2 AST-GP Clindlamycin is designed for antimicrobial susceptibility testing of Staphylococcus aureus and Staphylococcus epiderniidis. VITEK 2 AST-GP Clindlamycin is a quantitative test intended for use with the VITEK® 2 and VITEK® 2 Compact Systems as a laboratory aid in the determination of in vitro susceptibility to antimicrobial agents. Clindamycin has been shown to be active against most strains of the microorganism listed below, according to the FDA label for this antimicrobial.
Active in vitro and in clinical infections
Staphylococcus aureus (methicillin-susceptible strains) and Staphylococcus epiderniidis (methicillin-susceptible strains)
The VITEK® 2 Antimicrobial Susceptibility Test (AST.) is intended to be used with the VITEK® 2 and VITEK 2 Compact Systems for the automated quantitative or qualitative susceptibility testing of isolated colonies for the most clinically significant aerobic gram-negative bacilli, Staphylococcus apop., Enterococcus spp., Streptococcus agralactiae, and S. pneumoniae.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K122547 · printed Nov 6, 2026
Cite this page
510(k) Report. “K122547: Gram Postitve Clindamycin.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K122547
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026