510(k) Report

510(k) · Cleared

Cleared

Preview Forward-Looking Ivus Catheter and Laptop System; Preview Catheter Model 87000; Pimf Model 87-Pimf; Laptop System

K122826510(k) TraditionalCleared Apr 24, 2013222-day reviewClass II21 CFR 870.1250

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Volcano Corporation · DQY Catheter, Percutaneous

Cleared on Apr 24, 2013 as substantially equivalent to K080891 (Volcano Corporation, 2008) and 2 other predicates after a 222-day review. Its family tree reaches back 9 generations to 1995. 1 later device descends from it.

Decided
Apr 24, 2013
Review
222 days
Class
Class II
Product code
DQY
Recalls
None
Predicates
3

Its longest line of descent runs back 9 generations to K934139 (1995). 49 ancestors in all, the oldest K823434 (1982). 1 later device descends from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2011: 1 other ancestor2008: 1 other ancestor2005: 3 other ancestors1998: 3 other ancestors2004: 2 other ancestors2003: 2 other ancestors2002: 1 other ancestor1997: 3 other ancestors1994: 3 other ancestors1993: 3 other ancestors1992: 5 other ancestors2007: 1 other ancestor2006: 1 other ancestor2000: 2 other ancestors1996: 3 other ancestors1995: 2 other ancestors1991: 1 other ancestor1990: 1 other ancestor1986: 1 other ancestor1982: 1 other ancestor2013: 1 descendant clearedK934139 · Tomtec Echo-View · Tomtec Tomographic Technologies GmbH · 1995K993398 · Echo View, Easy View, Omni View · Tomtec Imaging Systems GmbH · 1999K022824 · Echo-View 5.X, Easy-View 2.X, Omni View 2.X, Cardio-View 1.X, LV Analysis 1.X & Surgical View 1.X · Tomtec Imaging Systems GmbH · 2002K042188 · Volcano Therapeutics, Inc. Volcano Ivus System · Volcano Therapeutics, Inc. · 2004K051337 · Eagle Eye Gold Ivus Imaging Catheter, Model 85900/859XX; Volcano VH-Ivus System, Model 8049XX-001 · Volcano Corporation · 2005K071554 · Volcano S5/S5I Intravascular Imaging and Pressure System · Volcano Corporation · 2008 · recalledK082229 · S5/S5I Series Intravascular Imaging and Pressure System, Combomap Pressure and Flow System · Volcano Corporation · 2008 · recalledK111706 · Volcano S5IINTRAVASCULAR Imaging and Pressure System · Volcano Corporation · 2011 · recalledK113486 · Volcano S5I Intravascular Ultracound Imaging and Pressure System · Volcano Corporation · 201219801990200020102020
  1. Root · 9 generations backK934139 Tomtec Echo-ViewTomtec Tomographic Technologies GmbH · 1995
  2. 5 generations between
  3. 3 generations backK082229 S5/S5I Series Intravascular Imaging and Pressure System, Combomap…Volcano Corporation · 2008 · Recalled
  4. 2 generations backK111706 Volcano S5IINTRAVASCULAR Imaging and Pressure SystemVolcano Corporation · 2011 · Recalled
  5. 1 generation backK113486 Volcano S5I Intravascular Ultracound Imaging and Pressure SystemVolcano Corporation · 2012
  6. This deviceK122826 Preview Forward-Looking Ivus Catheter and Laptop System; Preview…Volcano Corporation · 2013
  7. Descendant · cites it directly · 0 of its ownK132659 Volcano Preview Forward-Looking Ivus SystemVolcano Corporation · 2013
Show all 9 generations
  1. Root · 9 generations backK934139 Tomtec Echo-ViewTomtec Tomographic Technologies GmbH · 1995
  2. 8 generations backK993398 Echo View, Easy View, Omni ViewTomtec Imaging Systems GmbH · 1999
  3. 7 generations backK022824 Echo-View 5.X, Easy-View 2.X, Omni View 2.X, Cardio-View 1.X, LV…Tomtec Imaging Systems GmbH · 2002
  4. 6 generations backK042188 Volcano Therapeutics, Inc. Volcano Ivus SystemVolcano Therapeutics, Inc. · 2004
  5. 5 generations backK051337 Eagle Eye Gold Ivus Imaging Catheter, Model 85900/859XX; Volcano…Volcano Corporation · 2005
  6. 4 generations backK071554 Volcano S5/S5I Intravascular Imaging and Pressure SystemVolcano Corporation · 2008 · Recalled
  7. 3 generations backK082229 S5/S5I Series Intravascular Imaging and Pressure System, Combomap…Volcano Corporation · 2008 · Recalled
  8. 2 generations backK111706 Volcano S5IINTRAVASCULAR Imaging and Pressure SystemVolcano Corporation · 2011 · Recalled
  9. 1 generation backK113486 Volcano S5I Intravascular Ultracound Imaging and Pressure SystemVolcano Corporation · 2012
  10. This deviceK122826 Preview Forward-Looking Ivus Catheter and Laptop System; Preview…Volcano Corporation · 2013

Most influential descendants

Showing 1 of 1 · See all
  • K132659Volcano Preview Forward-Looking Ivus SystemVolcano Corporation · 2013 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−9K934139Tomtec Echo-ViewTomtec Tomographic Technologies GmbH1995—
−8K993398Echo View, Easy View, Omni ViewTomtec Imaging Systems GmbH1999—
−7K022824Echo-View 5.X, Easy-View 2.X, Omni View 2.X, Cardio-View 1.X, LV Analysis 1.X…Tomtec Imaging Systems GmbH2002—
−6K042188Volcano Therapeutics, Inc. Volcano Ivus SystemVolcano Therapeutics, Inc.2004—
−5K051337Eagle Eye Gold Ivus Imaging Catheter, Model 85900/859XX; Volcano VH-Ivus…Volcano Corporation2005—
−4K071554Volcano S5/S5I Intravascular Imaging and Pressure SystemVolcano Corporation20082
−3K082229S5/S5I Series Intravascular Imaging and Pressure System, Combomap Pressure and…Volcano Corporation20083
−2K111706Volcano S5IINTRAVASCULAR Imaging and Pressure SystemVolcano Corporation20111
−1K113486Volcano S5I Intravascular Ultracound Imaging and Pressure SystemVolcano Corporation2012—
0 (this device)K122826Preview Forward-Looking Ivus Catheter and Laptop System; Preview Catheter…Volcano Corporation2013—
+1K132659Volcano Preview Forward-Looking Ivus SystemVolcano Corporation2013—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198210
198610
199010
199110
199250
199330
199430
199520
199630
199730
199830
200020
200210
200320
200420
200530
200610
200710
200810
201110

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201310
FIG. 1 — Lineage of K122826, 1995–2013Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DQY? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DQY device

  1. #1 K234115 APRO 55 Catheterscore 17.5 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (3)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K080891Revolution 45MHZ Ivus Imaging Catheter
Summary page 1
…CFR Part 870.1250 Class II Device PREDICATE DEVICE: Volcano Revolutionlo Catheter (K080891) Volcano s5/s5i Imaging System (Ki 13486)…
Volcano Corporation2008—
*K113486Volcano S5I Intravascular Ultracound Imaging and Pressure SystemVolcano Corporation2012—
*K111704Avinger Wildcat 6F Guidewire Support Catheter and JuiceboxAvinger, Inc.2011—

Also cleared against K080891: 1 other device →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K132659Volcano Preview Forward-Looking Ivus SystemVolcano Corporation20130

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 18 years and passes through 4 companies; a new generation was cleared every 2.1 years on median.
  • 5 of the 49 ancestors have a recall of any class.
  • Of its descendants, K132659 (Volcano Corporation, 2013) has gone furthest, with 0 descendants of its own.
  • 1 other device also cites its predicate K080891.

How does its category compare?

All DQY devices

DQY Catheter, Percutaneous: FDA decisions, review times, recalls and adverse event reports over 20 years. 2013, this device’s year, is highlighted.

FDA decisions per year · DQY

21in 2025

2007: 162008: 312009: 372010: 222011: 362012: 302013: 322014: 192015: 272016: 222017: 262018: 252019: 302020: 202021: 182022: 182023: 182024: 162025: 212026 (partial year): 11
2007high 37 (2009) · low 16 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DQY

115in 2025

2007: 85 days median2008: 66 days median2009: 73 days median2010: 74 days median2011: 71 days median2012: 87 days median2013: 92 days median2014: 127 days median2015: 118 days median2016: 117 days median2017: 113 days median2018: 106 days median2019: 111 days median2020: 120 days median2021: 81 days median2022: 74 days median2023: 114 days median2024: 87 days median2025: 115 days median2026 (partial year): 30 days median
2007high 127 (2014) · low 66 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DQY

1in 2025

2007: 62008: 122009: 172010: 322011: 62012: 22013: 36, 1 Class I2014: 32015: 32016: 22, 7 Class I2017: 82018: 22019: 12020: 22021: 22023: 172024: 12025: 1, 1 Class I2026 (partial year): 2, 1 Class I
2007high 36 (2013) · low 0 (2022)2026

Class I (10 since 2007) Class II/III not classified

Adverse event reports per year · DQY

3,056in 2025

2007: 3132008: 4962009: 8192010: 1,2932011: 1,2112012: 1,1912013: 1,3522014: 1,4972015: 2,3372016: 2,2522017: 2,4892018: 2,8552019: 2,9022020: 2,8892021: 3,0062022: 2,6432023: 3,0492024: 3,1902025: 3,056
2007high 3,190 (2024) · low 313 (2007)2025

MAUDE reports naming product code DQY, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200716856313
2008316612496
2009377317819
20102274321,293
2011367161,211
2012308721,191
2013329236 (1)1,352
20141912731,497
20152711832,337
20162211722 (7)2,252
20172611382,489
20182510622,855
20193011112,902
20202012022,889
2021188123,006
2022187402,643
202318114173,049
2024168713,190
2025211151 (1)3,056
202611302 (1)—

What is it indicated for?

The PreView® Forward-Looking IVUS Catheter and Laptop System is indicated for use to facilitate the intraluminal placement of guidewires in the peripheral vasculature prior to further percutaneous intervention and to support guidewires in accessing discrete regions of the peripheral vasculature, to assess vessel morphology, assess the position of the catheter tip within the vessel lumen, and to facilitate placement and exchanges of guidewires and other…

Read the full statement (133 words)

The PreView® Forward-Looking IVUS Catheter and Laptop System is indicated for use to facilitate the intraluminal placement of guidewires in the peripheral vasculature prior to further percutaneous intervention and to support guidewires in accessing discrete regions of the peripheral vasculature, to assess vessel morphology, assess the position of the catheter tip within the vessel lumen, and to facilitate placement and exchanges of guidewires and other interventional devices compatible with 0.014" guidewire lumens. The Preview® Forward-Looking IVUS Catheter is designed as an adjunct to conventional angiographic procedures to provide a forward-looking image of the vessel lumen and wall structures.

The PreView® Forward-Looking IVUS Catheter and Laptop System is not indicated for use for imaging with the exposed rotating tip inside a stent. This device is not indicated for use in coronary or cerebral vessels.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K122826: Preview Forward-Looking Ivus Catheter and Laptop System; Preview Catheter Model 87000; Pimf Model 87-Pimf; Laptop System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K122826

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026