Cleared on Dec 7, 2012 as substantially equivalent to K092631 (Stryker Spine, 2009) and 1 other predicate after an 81-day review. Its family tree reaches back 8 generations to 1995. 28 later devices descend from it.
- Decided
- Dec 7, 2012
- Review
- 81 days
- Class
- Class II
- Product code
- NKB
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 8 generations to K950697 (1995). 45 ancestors in all. 28 later devices descend from it, 7 citing it directly.
- Root · 8 generations backK950697 Depuy Motech Moss Miami Spinal System - Pedicle FixationDepuy Motech · 1995
- 7 generations backK050461 Xia 4.5 Spinal SystemStryker Spine · 2005
- 6 generations backK052761 Modification to: Xia 4.5 Spinal SystemStryker Spine · 2005
- 5 generations backK060361 Xia Spinal System, Xia 4.5 Spinal SystemStryker Spine · 2006 · Recalled
- 4 generations backK061854 Xia Titanium Spinal System and Xia Stainless Steel Spinal SystemStryker Spine · 2006
- 3 generations backK063428 Xia Stainless Steel Spinal SystemStryker Spine · 2006
- 2 generations backK092631 Mantis Redux Spinal SystemStryker Spine · 2009
- 1 generation backK102235 Mantis Spinal System & Mantis Redux Spinal SystemStryker Spine · 2010
- This deviceK122845 ES2 Spinal System Model 48280XXXXStryker Spine · 2012
- Descendant · cites it directly · 9 of its ownK140400 ES2 Neuromonitoring Accessory InstrumentsStryker Corporation · 2014
- Descendant · cites it directly · 8 of its ownK192818 Vertaplex HV High Viscosity Radiopaque Bone Cement; ES2 Augmentable…Stryker Corporation · 2020
- Descendant · 2 generations on · 7 of its ownK171807 ES2 Neuromonitoring Accessory InstrumentsStryker Corporation · 2017
- Descendant · cites it directly · 4 of its ownK222684 XIA® 4.5 Spinal System, XIA® 4.5 Cortical Trajectory, XIA® 3 Spinal…Stryker Spine · 2023
- Descendant · 2 generations on · 4 of its ownK142438 Nerve Monitoring Cable SystemPioneer Surgical Technology, Inc. (Rti Surgical, Inc.) · 2015
Showing 5 of 28 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 28 · See all- K140400ES2 Neuromonitoring Accessory InstrumentsStryker Corporation · 2014 · cites it directly9descendants
- K192818Vertaplex HV High Viscosity Radiopaque Bone Cement; ES2 Augmentable Spinal SystemStryker Corporation · 2020 · cites it directly8descendants
- K171807ES2 Neuromonitoring Accessory InstrumentsStryker Corporation · 2017 · 2 generations on7descendants
- K222684XIA® 4.5 Spinal System, XIA® 4.5 Cortical Trajectory, XIA® 3 Spinal System, Serrato®…Stryker Spine · 2023 · cites it directly4descendants
- K142438Nerve Monitoring Cable SystemPioneer Surgical Technology, Inc. (Rti Surgical, Inc.) · 2015 · 2 generations on4descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −8 | K950697 | Depuy Motech Moss Miami Spinal System - Pedicle Fixation | Depuy Motech | 1995 | — |
| −7 | K050461 | Xia 4.5 Spinal System | Stryker Spine | 2005 | — |
| −6 | K052761 | Modification to: Xia 4.5 Spinal System | Stryker Spine | 2005 | — |
| −5 | K060361 | Xia Spinal System, Xia 4.5 Spinal System | Stryker Spine | 2006 | 1 |
| −4 | K061854 | Xia Titanium Spinal System and Xia Stainless Steel Spinal System | Stryker Spine | 2006 | — |
| −3 | K063428 | Xia Stainless Steel Spinal System | Stryker Spine | 2006 | — |
| −2 | K092631 | Mantis Redux Spinal System | Stryker Spine | 2009 | — |
| −1 | K102235 | Mantis Spinal System & Mantis Redux Spinal System | Stryker Spine | 2010 | — |
| 0 (this device) | K122845 | ES2 Spinal System Model 48280XXXX | Stryker Spine | 2012 | — |
| +1 | K140400 | ES2 Neuromonitoring Accessory Instruments | Stryker Corporation | 2014 | — |
| +1 | K192818 | Vertaplex HV High Viscosity Radiopaque Bone Cement; ES2 Augmentable Spinal… | Stryker Corporation | 2020 | — |
| +2 | K171807 | ES2 Neuromonitoring Accessory Instruments | Stryker Corporation | 2017 | — |
| +1 | K222684 | XIA® 4.5 Spinal System, XIA® 4.5 Cortical Trajectory, XIA® 3 Spinal System… | Stryker Spine | 2023 | — |
| +2 | K142438 | Nerve Monitoring Cable System | Pioneer Surgical Technology, Inc. (Rti Surgical, Inc.) | 2015 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1995 | 1 | 0 |
| 1997 | 1 | 0 |
| 1998 | 1 | 0 |
| 1999 | 3 | 0 |
| 2000 | 4 | 0 |
| 2001 | 4 | 0 |
| 2002 | 2 | 0 |
| 2003 | 5 | 0 |
| 2004 | 5 | 0 |
| 2005 | 4 | 0 |
| 2006 | 4 | 0 |
| 2007 | 2 | 0 |
| 2008 | 1 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2014 | 1 | 0 |
| 2015 | 1 | 0 |
| 2016 | 1 | 0 |
| 2017 | 2 | 0 |
| 2019 | 4 | 0 |
| 2020 | 3 | 0 |
| 2021 | 1 | 0 |
| 2022 | 2 | 0 |
| 2023 | 5 | 0 |
| 2024 | 5 | 0 |
| 2025 | 2 | 0 |
| 2026 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in NKB? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new NKB device
- #1 K223494 CD Horizon Spinal Systemscore 40.4 · 30 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K092631 | Mantis Redux Spinal SystemSummary page 1…ared: December 6, 2012' Predicate Devices Stryker Spine MANT"IS® Redux Spinal System, K(092631 and .K102235 Description of Device Modification… | 2009 |
| * | K102235 | Mantis Spinal System & Mantis Redux Spinal SystemSummary page 1…Stryker Spine MANT"IS® Redux Spinal System, K(092631 and .K102235 Description of Device Modification This 510(k) is intended to introdUce anl extension to the existinlg… | 2010 |
What descends from it? (28)
See all 287 later devices cite it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K140400 | ES2 Neuromonitoring Accessory Instruments | 2014 | 9 |
| K192818 | Vertaplex HV High Viscosity Radiopaque Bone Cement; ES2 Augmentable Spinal System | 2020 | 8 |
| K222684 | XIA® 4.5 Spinal System, XIA® 4.5 Cortical Trajectory, XIA® 3 Spinal System, Serrato®… | 2023 | 4 |
| K200666 | Stryker Xia 3 Power Adaptor | 2020 | 3 |
| K172808 | CosmoLock Pedicle Screw System | 2017 | 2 |
| K162367 | Erisma® LP MIS | 2016 | 2 |
| K202528 | Cannulated Power Driver Attachment | 2020 | 0 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 17 years and passes through 2 companies; a new generation was cleared every 11 months on median.
- 4 of the 45 ancestors have a recall of any class.
- Of its descendants, K140400 (Stryker Corporation, 2014) has gone furthest, with 9 descendants of its own.
- 2 other devices also cite its predicate K092631.
How does its category compare?
All NKB devicesNKB Thoracolumbosacral Pedicle Screw System: FDA decisions, review times, recalls and adverse event reports over 20 years. 2012, this device’s year, is highlighted.
FDA decisions per year · NKB
24in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · NKB
61in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · NKB
1in 2025
Class I (1 since 2007) Class II/III not classified
Adverse event reports per year · NKB
1,171in 2025
MAUDE reports naming product code NKB, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 38 | 87 | 4 | 34 |
| 2008 | 36 | 59 | 5 | 82 |
| 2009 | 44 | 71 | 33 | 171 |
| 2010 | 37 | 111 | 4 | 462 |
| 2011 | 48 | 84 | 3 | 577 |
| 2012 | 60 | 79 | 13 | 1,747 |
| 2013 | 35 | 73 | 0 | 1,962 |
| 2014 | 46 | 90 | 3 (1) | 1,671 |
| 2015 | 55 | 90 | 3 | 1,446 |
| 2016 | 50 | 84 | 1 | 1,585 |
| 2017 | 63 | 69 | 1 | 1,618 |
| 2018 | 56 | 61 | 3 | 1,684 |
| 2019 | 39 | 84 | 1 | 1,915 |
| 2020 | 48 | 68 | 1 | 2,076 |
| 2021 | 32 | 61 | 0 | 1,745 |
| 2022 | 34 | 88 | 5 | 1,339 |
| 2023 | 44 | 72 | 2 | 919 |
| 2024 | 39 | 57 | 3 | 1,614 |
| 2025 | 24 | 61 | 1 | 1,171 |
| 2026 | 30 | 91 | 3 | — |
What is it indicated for?
The ES2 TM Spinal System is intended for percutaneous, posterior, non-cervical pedicle fixation of the spine to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion for the following indications: * Degenerative Disc Disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies), * Spondylolisthesis, * Trauma (i.e. fracture or…
Read the full statement (532 words)
The ES2 TM Spinal System is intended for percutaneous, posterior, non-cervical pedicle fixation of the spine to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion for the following indications:
* Degenerative Disc Disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies),
* Spondylolisthesis,
* Trauma (i.e. fracture or dislocation),
* Spinal stenosis,
* Curvatures (i.e. scoliosis, kyphosis, and/or lordosis),
* Tumor,
* Pseudoarthrosis, and
* Failed previous fusion.
The Titanium and Vitallium® rods from the Stryker Spine RADIUS®, MANTIS® and MANTIS® Redux Spinal Systems are intended to be used with the other components of the ES2 TM Spinal System.
To facilitate the placement of pedicle screws using the power technique (corded and cordless), the use of the Stryker Spine Power Adaptor is intended for exclusive use with the Stryker Instruments Hudson Modified Trinkle Reamer and the Stryker Instruments CD3 Cordless Driver 3 and the Stryker Instruments RemB Universal Driver. When the power adaptors are attached, the CD3 Cordless Driver 3 and RemB Universal Driver provide power (corded and cordless) to rotate screwdrivers for the insertion of pedicle screws.
Pedicle screws from select Stryker Spine implant systems may be implanted in the skeletally mature non-cervical spine using powered (corded and cordless) instrumentation. The systems included are the family of Xia Spinal Systems (Xia Stainless Steel, Xia 11, Xia Anterior, and Xia Precision), Xia 3 Spinal System, Xia 4.5 Spinal System, Radius Spinal System and MANTIS® Spinal System, MANTIS® Redux Spinal System and the ES2 TM Spinal System.
The Xia Spinal System is intended for anterior/anteriolateral and posterior, non-cervical pedicle and non-pedicle fixation in skeletally mature patients as an adjunct to fusion for the following indications: degenerative disc disease (DDD) (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies); spondylolisthesis; trauma (i.e. fracture or dislocation); spinal stenosis; curvature (i.e. scoliosis, kyphosis, and/or lordosis); tumor; pseudoarthrosis; and failed previous fusion.
The XIA 4.5, Xia 3, Radius Spinal Systems are intended for use in the non-cervical spine. When used as an anterior/anteriolateral and posterior, non-cervical pedicle and non-pedicle fixation system, the Xia 3, XIA 4.5, Xia 3, and Radius Spinal Systems are intended to provide additional support during fusion using autograft or allograft in skeletally mature patients in the treatment of the following acute and chronic instabilities or deformities: degenerative disc disease (DDD) (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies); spondylolisthesis; trauma (i.e. fracture or dislocation); spinal stenosis; curvatures (i.e. scoliosis, kyphosis, and/or lordosis); tumor; pseudoarthrosis; and failed previous fusion.
The MANTIS® Spinal System, MANTIS® Redux Spinal System and ES2 TM Spinal System is intended for percutaneous, posterior, non-cervical pedicle and non-pedicle fixation of the spine to provide immobilization and stabilization of spinal segments in skeletally mature patients as an adjunct to fusion for the following indications: degenerative disc disease (defined as back pain of discogenic origin with degeneration of the disc confirmed by history and radiographic studies); spondylolisthesis; trauma (i.e. fracture or dislocation); spinal stenosis; curvatures (i.e. scoliosis, kyphosis, and/or lordosis); tumor; pseudoarthrosis; and failed previous fusion.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K122845 · printed Nov 4, 2026
Cite this page
510(k) Report. “K122845: ES2 Spinal System Model 48280XXXX.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K122845
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026