510(k) · Cleared
ClearedBD Pen Needle
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Becton, Dickinson & CO · FMI Needle, Hypodermic, Single Lumen
Cleared on Jan 18, 2013 as substantially equivalent to K100005 (Becton, Dickinson and Co., 2010) and 1 other predicate after an 87-day review. Its family tree reaches back 2 generations to 2005. 20 later devices descend from it.
- Decided
- Jan 18, 2013
- Review
- 87 days
- Class
- Class II
- Product code
- FMI
- Recalls
- None
- Predicates
- 2
Its longest line of descent runs back 2 generations to K051899 (2005). 20 later devices descend from it, 3 citing it directly.
- Root · 2 generations backK051899 BD Pen NeedleBecton, Dickinson & CO · 2005
- 1 generation backK100005 BD Pen NeedleBecton, Dickinson and Co. · 2010
- This deviceK123300 BD Pen NeedleBecton, Dickinson & CO · 2013
- Descendant · cites it directly · 11 of its ownK131358 BD Pen NeedleBecton, Dickinson & CO · 2013
- Descendant · 2 generations on · 10 of its ownK162516 BD Pen NeedleBecton, Dickinson and Company · 2016 · Recalled
- Descendant · cites it directly · 4 of its ownK140516 Terumo Pen Injector Needle 34Kofu Factory of Terumo Corp. · 2014
- Descendant · 3 generations on · 3 of its ownK171982 Droplet Pen NeedleHtl-Strefa S.A · 2018
- Descendant · 2 generations on · 2 of its ownK192082 Droplet Pen Needle 34GHtl-Strefa S.A · 2020
Showing 5 of 20 descendants. See all descendants
Descendants cleared per year
Most influential descendants
Showing 5 of 20 · See all- K131358BD Pen NeedleBecton, Dickinson & CO · 2013 · cites it directly11descendants
- K162516BD Pen NeedleBecton, Dickinson and Company · 2016 · 2 generations on10descendants
- K140516Terumo Pen Injector Needle 34Kofu Factory of Terumo Corp. · 2014 · cites it directly4descendants
- K171982Droplet Pen NeedleHtl-Strefa S.A · 2018 · 3 generations on3descendants
- K192082Droplet Pen Needle 34GHtl-Strefa S.A · 2020 · 2 generations on2descendants
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −2 | K051899 | BD Pen Needle | Becton, Dickinson & CO | 2005 | — |
| −1 | K100005 | BD Pen Needle | Becton, Dickinson and Co. | 2010 | — |
| 0 (this device) | K123300 | BD Pen Needle | Becton, Dickinson & CO | 2013 | — |
| +1 | K131358 | BD Pen Needle | Becton, Dickinson & CO | 2013 | — |
| +2 | K162516 | BD Pen Needle | Becton, Dickinson and Company | 2016 | 2 |
| +1 | K140516 | Terumo Pen Injector Needle 34 | Kofu Factory of Terumo Corp. | 2014 | — |
| +3 | K171982 | Droplet Pen Needle | Htl-Strefa S.A | 2018 | — |
| +2 | K192082 | Droplet Pen Needle 34G | Htl-Strefa S.A | 2020 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2013 | 1 | 0 |
| 2014 | 2 | 0 |
| 2016 | 1 | 0 |
| 2018 | 2 | 0 |
| 2020 | 4 | 0 |
| 2021 | 3 | 0 |
| 2022 | 2 | 0 |
| 2023 | 3 | 0 |
| 2025 | 1 | 0 |
| 2026 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in FMI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new FMI device
- #1 K252886 Pen Needlescore 14.5 · 4 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (2)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K100005 | BD Pen NeedleSummary page 1…, Hypodermic, Single Lumen Classification: Class 11, 21 CFR 880.5570 EMI 3. Predicate Device: RD Pen Needle- K100005 and K05 1899 Manufactured by: Becton, Dickinson and Company 4. Device Description: BD… | 2010 |
| * | K051899 | BD Pen NeedleSummary page 1…, Single Lumen Classification: Class 11, 21 CFR 880.5570 EMI 3. Predicate Device: RD Pen Needle- K100005 and K05 1899 Manufactured by: Becton, Dickinson and Company 4. Device Description: BD pen needles a… | 2005 |
What descends from it? (20)
See all 203 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 8 years and passes through 2 companies; a new generation was cleared every 4.6 years on median.
- None of the 2 ancestors has a recall.
- Of its descendants, K131358 (Becton, Dickinson & CO, 2013) has gone furthest, with 11 descendants of its own.
- 9 other devices also cite its predicate K100005.
How does its category compare?
All FMI devicesFMI Needle, Hypodermic, Single Lumen: FDA decisions, review times, recalls and adverse event reports over 20 years. 2013, this device’s year, is highlighted.
FDA decisions per year · FMI
11in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · FMI
141in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · FMI
1in 2024
Class I (1 since 2007) Class II/III not classified
Adverse event reports per year · FMI
2,424in 2025
MAUDE reports naming product code FMI, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 15 | 71 | 2 | 208 |
| 2008 | 10 | 85 | 4 | 177 |
| 2009 | 7 | 177 | 3 | 263 |
| 2010 | 15 | 119 | 79 | 249 |
| 2011 | 12 | 113 | 5 | 240 |
| 2012 | 17 | 107 | 1 | 215 |
| 2013 | 11 | 87 | 1 | 255 |
| 2014 | 14 | 155 | 3 | 287 |
| 2015 | 10 | 89 | 1 | 567 |
| 2016 | 20 | 217 | 0 | 941 |
| 2017 | 9 | 253 | 16 | 1,547 |
| 2018 | 20 | 176 | 0 | 2,398 |
| 2019 | 12 | 186 | 5 | 4,896 |
| 2020 | 11 | 263 | 3 | 4,245 |
| 2021 | 18 | 143 | 7 | 4,532 |
| 2022 | 23 | 189 | 0 | 4,885 |
| 2023 | 18 | 112 | 2 | 4,986 |
| 2024 | 3 | 90 | 1 | 4,053 |
| 2025 | 11 | 141 | 0 | 2,424 |
| 2026 | 12 | 119 | 1 (1) | — |
What is it indicated for?
BD Pen Needle is intended for use with pen injector device for subcutaneous injection of drugs, including insulin and exenatide.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K123300 · printed Nov 5, 2026
Cite this page
510(k) Report. “K123300: BD Pen Needle.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K123300
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026