510(k) · Decided
Recalled · Class II · 2016Amt Low-Profile Transgastric-Jejunal Feeding Tube Kit
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Applied Medical Technology, Inc. · KNT Tubes, Gastrointestinal (And Accessories)
Cleared on Apr 19, 2013 after a 136-day review. FDA’s file for it is a 510(k) statement, which names no predicate. 2 later devices descend from it. It has been recalled once.
- Decided
- Apr 19, 2013
- Review
- 136 days
- Class
- Class II
- Product code
- KNT
- Recalls
- 1
- Predicates
- 0
2 later devices descend from it, 2 citing it directly.
- This deviceK123716 Amt Low-Profile Transgastric-Jejunal Feeding Tube KitApplied Medical Technology, Inc. · 2013
- Descendant · cites it directly · 0 of its ownK183508 Micro Transgastric-Jejunal Feeding DeviceApplied Medical Technology, Inc. · 2019
- Descendant · cites it directly · 0 of its ownK182804 Traditional Length GJ Feeding DeviceApplied Medical Technology, Inc. · 2019
Most influential descendants
Showing 2 of 2 · See allView FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| 0 (this device) | K123716 | Amt Low-Profile Transgastric-Jejunal Feeding Tube Kit | Applied Medical Technology, Inc. | 2013 | — |
| +1 | K183508 | Micro Transgastric-Jejunal Feeding Device | Applied Medical Technology, Inc. | 2019 | — |
| +1 | K182804 | Traditional Length GJ Feeding Device | Applied Medical Technology, Inc. | 2019 | — |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2019 | 2 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA 510(k) statement (indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in KNT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new KNT device
- #1 K261890 52Fr ViSiGi LUX™; 52Fr ViSiGi 3D®score 12.8 · 4 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against?
FDA’s file for it is a 510(k) statement, which names no predicate.
What descends from it? (2)
2 later devices cite it directly; ranked here by how many devices descend from each in turn.
Has anything in its family been recalled? (0 Class I)
Recalls of this device
| Date | Class | Recall | Root cause | Reason |
|---|---|---|---|---|
| Jan 26, 2016 | Class II | Z-1497-2016 | Employee error | The firm received complaints that the product is shorter in length than indicated on the label. |
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Of its descendants, K183508 (Applied Medical Technology, Inc., 2019) has gone furthest, with 0 descendants of its own.
How does its category compare?
All KNT devicesKNT Tubes, Gastrointestinal (And Accessories): FDA decisions, review times, recalls and adverse event reports over 20 years. 2013, this device’s year, is highlighted.
FDA decisions per year · KNT
4in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · KNT
136in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · KNT
13in 2025
Class I (1 since 2007) Class II/III not classified
Adverse event reports per year · KNT
1,451in 2025
MAUDE reports naming product code KNT, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 10 | 118 | 1 | 300 |
| 2008 | 10 | 115 | 82 | 867 |
| 2009 | 11 | 102 | 9 | 818 |
| 2010 | 12 | 104 | 3 | 517 |
| 2011 | 7 | 211 | 2 | 531 |
| 2012 | 12 | 107 | 1 | 528 |
| 2013 | 7 | 128 | 0 | 747 |
| 2014 | 16 | 259 | 0 | 1,030 |
| 2015 | 10 | 140 | 1 | 1,048 |
| 2016 | 6 | 99 | 3 | 1,251 |
| 2017 | 9 | 247 | 4 | 1,672 |
| 2018 | 7 | 149 | 2 | 1,901 |
| 2019 | 10 | 126 | 2 | 1,838 |
| 2020 | 5 | 102 | 1 | 1,641 |
| 2021 | 6 | 121 | 2 | 1,655 |
| 2022 | 7 | 110 | 1 (1) | 1,650 |
| 2023 | 5 | 162 | 2 | 1,863 |
| 2024 | 9 | 103 | 0 | 1,344 |
| 2025 | 4 | 136 | 13 | 1,451 |
| 2026 | 3 | 105 | 20 | — |
What is it indicated for?
The AMT Transgastric-Jejunal feeding tube is indicated for use in patients who cannot absorb adequate nutrition through the stomach, who have intestinal motility problems, gastric outlet obstruction, severe gastroesophageal reflux, are at risk of aspiration, or in those who have had previous esophagectomy or gastrectomy. The use of this tube is also clinically indicated when simultaneous gastric decompression and jejunal feeding are needed. This includes patients in whom malnutrition already exists, or may result, secondary to concurrent conditions.
Indications for use as stated in the FDA 510(k) statement.
https://510kreport.com/device/K123716 · printed Nov 3, 2026
Cite this page
510(k) Report. “K123716: Amt Low-Profile Transgastric-Jejunal Feeding Tube Kit.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K123716
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026