510(k) Report

510(k) · Cleared

Cleared

Imageqube

K124048510(k) TraditionalCleared Jan 29, 201329-day reviewClass II21 CFR 892.2050

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Intuitive Imaging Informatics, LLC · LLZ System, Image Processing, Radiological

Cleared on Jan 29, 2013 as substantially equivalent to K051037 (Intuitive Imaging Informatics, LLC, 2005) and 3 other predicates after a 29-day review. Its family tree reaches back 7 generations to 1996.

Decided
Jan 29, 2013
Review
29 days
Class
Class II
Product code
LLZ
Recalls
None
Predicates
4

Its longest line of descent runs back 7 generations to K954678 (1996). 14 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 7 generations backK954678 Pro VisionAlgotec Systems, Ltd. · 1996
  2. 6 generations backK980648 Pro VisionAlgotec Systems, Ltd. · 1998
  3. 5 generations backK992654 Plug 'N View 3D, Version 1.0Voxar Limited · 1999
  4. 4 generations backK022970 Amicas Light Beam Workstation, Model 1.0Amicas, Inc. · 2002
  5. 3 generations backK062477 Amicas Vision Series Pacs, Model 4.3Amicas, Inc. · 2006
  6. 2 generations backK073526 Amicas Vision Series Pacs, Model 5.5Amicas, Inc. · 2008
  7. 1 generation backK082144 Amicas Pacs, Version 6.0Amicas, Inc. · 2008 · Recalled
  8. This deviceK124048 ImagequbeIntuitive Imaging Informatics, LLC · 2013
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−7K954678Pro VisionAlgotec Systems, Ltd.1996—
−6K980648Pro VisionAlgotec Systems, Ltd.1998—
−5K992654Plug 'N View 3D, Version 1.0Voxar Limited1999—
−4K022970Amicas Light Beam Workstation, Model 1.0Amicas, Inc.2002—
−3K062477Amicas Vision Series Pacs, Model 4.3Amicas, Inc.2006—
−2K073526Amicas Vision Series Pacs, Model 5.5Amicas, Inc.2008—
−1K082144Amicas Pacs, Version 6.0Amicas, Inc.200813
0 (this device)K124048ImagequbeIntuitive Imaging Informatics, LLC2013—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200110
200310
200410
200510
200610
200810
201010
FIG. 1 — Lineage of K124048, 1996–2013Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LLZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LLZ device

  1. #1 K230955 syngo Application Softwarescore 21.5 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (4)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K051037Imageqube Pacs
Summary page 2
…teristics between the devices. Modified ImageQube Amicas PACS Candelis Synapse IniageQube (K(051037) 6.0 ImageGrid Obliquus (K(082144) (K(080333)…
Intuitive Imaging Informatics, LLC2005—
*K082144Amicas Pacs, Version 6.0
Summary page 1
…892.2050 NUMBER PRODUCT CODE LLZ PREDICATE DEVICES: ImageQube (KOS 1037) Amicas PACS 6.0 (K082 144) Candelis ImageGrid (K080333) Synapse Obliquus MIP/MPRIFusion (K1…
Amicas, Inc.200813
*K080333Imagegrid
Summary page 1
…LLZ PREDICATE DEVICES: ImageQube (KOS 1037) Amicas PACS 6.0 (K082 144) Candelis ImageGrid (K080333) Synapse Obliquus MIP/MPRIFusion (K1 0088 1) Substantially Equivalent To: The ImageQube is subst…
Candelis, Inc.2008—
*K100881Synapse Obliquus Mip/MPR/Fusion
Summary page 1
…Amicas PACS 6.0 (K082 144) Candelis ImageGrid (K080333) Synapse Obliquus MIP/MPRIFusion (K1 0088 1) Substantially Equivalent To: The ImageQube is substantially equivalent in intended use, principal of operation and technologica…
Fujifilm Medical System U.S.A., Inc.2010—

Also cleared against K051037: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 17 years and passes through 4 companies; a new generation was cleared every 2.5 years on median.
  • 2 of the 14 ancestors have a recall of any class.
  • 1 other device also cites its predicate K051037.

How does its category compare?

All LLZ devices

LLZ System, Image Processing, Radiological: FDA decisions, review times, recalls and adverse event reports over 20 years. 2013, this device’s year, is highlighted.

FDA decisions per year · LLZ

58in 2025

2007: 762008: 942009: 702010: 512011: 1062012: 822013: 952014: 782015: 642016: 822017: 782018: 1042019: 742020: 812021: 832022: 652023: 872024: 622025: 582026 (partial year): 45
2007high 106 (2011) · low 51 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LLZ

173in 2025

2007: 36 days median2008: 52 days median2009: 62 days median2010: 98 days median2011: 79 days median2012: 87 days median2013: 84 days median2014: 89 days median2015: 90 days median2016: 90 days median2017: 107 days median2018: 105 days median2019: 107 days median2020: 115 days median2021: 116 days median2022: 137 days median2023: 157 days median2024: 131 days median2025: 173 days median2026 (partial year): 110 days median
2007high 173 (2025) · low 36 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LLZ

11in 2025

2007: 202008: 322009: 212010: 172011: 302012: 122013: 642014: 62015: 162016: 122017: 52018: 72019: 22020: 62021: 32022: 42023: 82024: 62025: 112026 (partial year): 14
2007high 64 (2013) · low 2 (2019)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LLZ

116in 2025

2007: 1522008: 1542009: 1452010: 1452011: 4542012: 2662013: 1,1302014: 15,6312015: 2112016: 2902017: 1042018: 722019: 882020: 822021: 702022: 282023: 262024: 422025: 116
2007high 15,631 (2014) · low 26 (2023)2025

MAUDE reports naming product code LLZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007763620152
2008945232154
2009706221145
2010519817145
20111067930454
2012828712266
20139584641,130
20147889615,631
2015649016211
2016829012290
2017781075104
2018104105772
201974107288
202081115682
202183116370
202265137428
202387157826
202462131642
20255817311116
20264511014—

What is it indicated for?

ImageQube is intended for use by a physician or other medical professionals in the display and interpretation of medical images and demographic detail from all institutional imaging modalities, including, but not limited to, CT, MRI, NM, DR, US, PET Fusion, Angio and MG (including display of DICOM overlays and 3D Mammography images), along with secondary capture devices, such as film digitizers or other imaging sources. The ImageQube is designed for…

Read the full statement (248 words)

ImageQube is intended for use by a physician or other medical professionals in the display and interpretation of medical images and demographic detail from all institutional imaging modalities, including, but not limited to, CT, MRI, NM, DR, US, PET Fusion, Angio and MG (including display of DICOM overlays and 3D Mammography images), along with secondary capture devices, such as film digitizers or other imaging sources. The ImageQube is designed for display, interpretation, storage and distribution of all modalities.

Only pre-processed DICOM For Presentation images can be interpreted for primary diagnosis in mammography. Lossy compressed mammographic images and digitized film screen images must not be viewed for primary image interpretations. Mammographic images may only be interpreted using an FDA approved monitor meeting all the technical specifications required by the FDA for the Performance of Screening and Diagnostic Mammography. Images that are printed to film must be done using an FDA-approved printer for the diagnosis of digital mammography images. Efficient mammography screening makes toolbars and thumbnails available on each monitor, while also handling DICOM overlay display.

Acquired medical images may be displayed and manipulated further utilizing Multi-Planar Reconstruction (MPR), Anatomic Triangulation (AT), Dynamic Cross-Referencing, Maximum Intensity Projection (MWP), Slab and 3-D display, sent to and retrieved by radiologists in-house at facilities or at remote sites, stored, archived or printed. The ImageQube can operate as an independent device, or can also be interfaced with Rational Imaging PACS systems. Annotated print pages, transcribed reports and Key Image Summaries can also be accessed.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K124048: Imageqube.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K124048

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026