510(k) Report

510(k) · Cleared

Cleared

Range + Qualicheck Level 1, Range + Qualicheck Level 2, Range + Qualicheck Level 3

K130236510(k) TraditionalCleared Mar 15, 201344-day reviewClass I21 CFR 862.1660

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Radiometer Medical Aps · JJS Controls For Blood-Gases, (Assayed And Unassayed)

Cleared on Mar 15, 2013 as substantially equivalent to K980135 (Radiometer America, Inc., 1998) after a 44-day review. Its family tree reaches back 3 generations to 1996.

Decided
Mar 15, 2013
Review
44 days
Class
Class I
Product code
JJS
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K952725 (1996). No later device cites it as a predicate yet.

  1. Root · 3 generations backK952725 MulticheckRadiometer America, Inc. · 1996
  2. 2 generations backK961355 MulticheckRadiometer America, Inc. · 1996
  3. 1 generation backK980135 QUALICHECK5+ Models S7730, S7740, S7750, S7760Radiometer America, Inc. · 1998 · Recalled
  4. This deviceK130236 Range + Qualicheck Level 1, Range + Qualicheck Level 2, Range +…Radiometer Medical Aps · 2013
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K952725MulticheckRadiometer America, Inc.1996—
−2K961355MulticheckRadiometer America, Inc.1996—
−1K980135QUALICHECK5+ Models S7730, S7740, S7750, S7760Radiometer America, Inc.19981
0 (this device)K130236Range + Qualicheck Level 1, Range + Qualicheck Level 2, Range + Qualicheck…Radiometer Medical Aps2013—
FIG. 1 — Lineage of K130236, 1996–2013Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JJS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K980135QUALICHECK5+ Models S7730, S7740, S7750, S7760
Summary page 2
…l 1-3 is substantially equivalent in Intended Use, fundamental scientific technology, features, and characteristics to the predicate:. 510(k) Number/Device Manufacture: k980135 QUALICHECKS±, Radiometer Medical ApS Similarities 'Issue.…
Radiometer America, Inc.19981

Also cleared against K980135: 5 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 17 years and passes through 2 companies; a new generation was cleared every 1.6 years on median.
  • 1 of the 3 ancestors has a recall of any class.
  • 5 other devices also cite its predicate K980135.

How does its category compare?

All JJS devices

JJS Controls For Blood-Gases, (Assayed And Unassayed): FDA decisions, review times, recalls and adverse event reports over 20 years. 2013, this device’s year, is highlighted.

FDA decisions per year · JJS

1in 2016

2013: 22015: 12016: 1
2007high 2 (2013) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JJS

Too few JJS 510(k)s in any year since 2007 to give a median.

Recalls per year · JJS

No recall names JJS since 2007.

Adverse event reports per year · JJS

1in 2018

2017: 12018: 1
2007high 1 (2017) · low 0 (2007)2025

MAUDE reports naming product code JJS, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20132—00
20140—00
20151—00
20161—00
20170—01
20180—01
20190—00
20200—00
20210—00
20220—00
20230—00
20240—00
20250—00
20260—0—

What is it indicated for?

For In Vitro Diagnostic Use. This Range± QUALICHECK solution i an assayed quality control system for evaluating the accuracy and precision of all parameters listed on the insert specifying the control ranges.

Analytes are:

pH, PCO 2, PO2, ctHb, SO2 , FO2Hb, FCOHb, FMetI-b, FHbF-, cKt, cNa', cCa2 1,cCF-, cGlu, cLac, ctBil

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K130236: Range + Qualicheck Level 1, Range + Qualicheck Level 2, Range + Qualicheck Level 3.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K130236

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026