510(k) Report

510(k) · Cleared

Cleared

RSP Modular Glenoid Baseplate, Glenoid Taper Adapter, Retaining Screw

K130550510(k) TraditionalCleared Mar 24, 2014385-day reviewClass II21 CFR 888.3660

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Encore Medical L.P. · PHX Shoulder Prosthesis, Reverse Configuration

Cleared on Mar 24, 2014 as substantially equivalent to K041066 (Encore Medical L.P., 2005) and 1 other predicate after a 385-day review. Its family tree reaches back 1 generation to 2005.

Decided
Mar 24, 2014
Review
385 days
Class
Class II
Product code
PHX
Recalls
None
Predicates
2

Its longest line of descent runs back 1 generation to K041066 (2005). 2 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 2008: 1 other ancestorK041066 · Encore Reverse Shoulder Prosthesis · Encore Medical L.P. · 2005 · recalled200620082010201220142016
Other ancestors, by generation 1 generation back: 1 other ancestor K041066 · Encore Reverse Shoulder Prosthesis · Encore Medical L.P. · 2005 · recalled0
  1. Root · 1 generation backK041066 Encore Reverse Shoulder ProsthesisEncore Medical L.P. · 2005 · Recalled
  2. This deviceK130550 RSP Modular Glenoid Baseplate, Glenoid Taper Adapter, Retaining ScrewEncore Medical L.P. · 2014
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K041066Encore Reverse Shoulder ProsthesisEncore Medical L.P.20054
0 (this device)K130550RSP Modular Glenoid Baseplate, Glenoid Taper Adapter, Retaining ScrewEncore Medical L.P.2014—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200810
FIG. 1 — Lineage of K130550, 2005–2014Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in PHX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new PHX device

  1. #1 K212737 INHANCE™ Reverse Shoulder Systemscore 28.4 · 15 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K041066Encore Reverse Shoulder Prosthesis
Summary page 4
…aseplate. The RSP Modular Glenoid Baseplate is a multiple piece construct as opposed to a single piece construct as the predicate Reverse Shoulder Prosthesis Baseplate (K041066). The RSP Modular Glenoid Baseplate is fabricated from wrought/forged Ti-6A 1-4V that conforms to ASTM F136. The bottom surface…
Encore Medical L.P.20054
*K080402Encore Shoulder Primary Humeral Stem, Model 500-00, Encore Shoulder Humeral Head, Model…
Summary page 4
…additional fixation. The RSP Modular Glenoid Baseplate female taper and male taper of the adapter have geometry identical to those used in the predicate Turon Shoulder (K080402). There are no changes to sterilization, packaging, indications or intended use. Indications for Use: Indicated for use in pat…
Encore Medical L.P.20084

Also cleared against K041066: 24 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • 2 of the 2 ancestors have a recall of any class.
  • 24 other devices also cite its predicate K041066.

How does its category compare?

All PHX devices

PHX Shoulder Prosthesis, Reverse Configuration: FDA decisions, review times, recalls and adverse event reports over 20 years. 2014, this device’s year, is highlighted.

FDA decisions per year · PHX

9in 2025

2007: 52008: 62009: 12010: 82011: 122012: 122013: 82014: 122015: 42016: 42017: 112018: 142019: 92020: 132021: 212022: 92023: 92024: 92025: 92026 (partial year): 18
2007high 21 (2021) · low 1 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · PHX

72in 2025

2007: 97 days median2008: 79 days median2010: 124 days median2011: 94 days median2012: 114 days median2013: 143 days median2014: 110 days median2015: 206 days median2016: 132 days median2017: 141 days median2018: 127 days median2019: 144 days median2020: 143 days median2021: 143 days median2022: 198 days median2023: 154 days median2024: 139 days median2025: 72 days median2026 (partial year): 130 days median
2007high 206 (2015) · low 72 (2025)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · PHX

3in 2025

2015: 22018: 12019: 32020: 32021: 82023: 72024: 12025: 32026 (partial year): 7
2007high 8 (2021) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · PHX

2,848in 2025

2015: 142016: 52017: 252018: 3232019: 5042020: 9862021: 1,4042022: 1,3422023: 1,4012024: 2,1422025: 2,848
2007high 2,848 (2025) · low 0 (2007)2025

MAUDE reports naming product code PHX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200759700
200867900
20091—00
2010812400
2011129400
20121211400
2013814300
20141211000
20154206214
2016413205
201711141025
2018141271323
201991443504
2020131433986
20212114381,404
2022919801,342
2023915471,401
2024913912,142
202597232,848
2026181307—

What is it indicated for?

Indicated for usc in patients with a grossly rotator cuff deficient shoulder joint with scvere arthropathy or a previously failed joint replacement with a grossly rotator cuff deficient shoulder joint. The paticnt’s joint must be anatomically and structurally suited to receive the selected implani(s), and a functional deltoid muscle is necessury to usc the device. The glenoid baseplate is intended for ccmentless application with the addition of screws for fixation. The humeral stem is intended for cemented use only.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K130550: RSP Modular Glenoid Baseplate, Glenoid Taper Adapter, Retaining Screw.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K130550

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026