510(k) Report

510(k) · Cleared

Cleared

Visi Mobile Monitoring System

K130709510(k) TraditionalCleared Oct 7, 2013206-day reviewClass II21 CFR 870.2300

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Sotera Wireless, Inc. · MWI Monitor, Physiological, Patient (Without Arrhythmia Detection Or Alarms)

Cleared on Oct 7, 2013 as substantially equivalent to K112478 (Sotera Wireless, Inc., 2012) and 1 other predicate after a 206-day review. Its family tree reaches back 7 generations to 1997. 19 later devices descend from it.

Decided
Oct 7, 2013
Review
206 days
Class
Class II
Product code
MWI
Recalls
None
Predicates
2

Its longest line of descent runs back 7 generations to K962603 (1997). 25 ancestors in all, the oldest K872291 (1987). 19 later devices descend from it, 3 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2012: 1 other ancestor2008: 1 other ancestor2005: 1 other ancestor2002: 2 other ancestors2007: 2 other ancestors2000: 1 other ancestor1998: 1 other ancestor1988: 1 other ancestor1999: 1 other ancestor1996: 2 other ancestors1995: 1 other ancestor1993: 1 other ancestor1987: 1 other ancestor1994: 1 other ancestor1989: 1 other ancestor2025: 3 descendants cleared2015: 5 descendants cleared2018: 5 descendants cleared2019: 2 descendants cleared2024: 1 descendant cleared2021: 1 descendant cleared2022: 1 descendant cleared2023: 1 descendant clearedK962603 · Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & Cables · Masimo Corp. · 1997K973887 · Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and Cables · Masimo Corp. · 1998K982255 · Model 2000 Pulse Oximeter · Ivy Biomedical Systems, Inc. · 1998K991823 · N-395 Pulse Oximeter, Model N-395 · Nellcor Puritan Bennett, Inc. · 1999K012451 · Propaq Encore Models 202, 204, 206; Propaq CS Models 242, 244, 246 · Welch Allyn Protocol, Inc. · 2001K032363 · Zoll M Series Nibp Option · Zoll Medical Corp · 2003K082599 · Non-Invasive Continuous Blood Pressure Monitoring System Cnap Monitor 500I, 500AT · Cnsystem Medizintechnik AG · 20081990200020102020
Other ancestors, by generationDescendants, by generation 1 generation back: 1 other ancestor2 generations back: 3 other ancestors3 generations back: 5 other ancestors4 generations back: 6 other ancestors5 generations back: 3 other ancestors 1 generation forward: 3 descendants2 generations forward: 3 descendants3 generations forward: 6 descendants4 generations forward: 4 descendants5 generations forward: 3 descendants K082599 · Non-Invasive Continuous Blood Pressure Monitoring System Cnap Monitor 500I, 500AT · Cnsystem Medizintechnik AG · 2008K032363 · Zoll M Series Nibp Option · Zoll Medical Corp · 2003K012451 · Propaq Encore Models 202, 204, 206; Propaq CS Models 242, 244, 246 · Welch Allyn Protocol, Inc. · 2001K991823 · N-395 Pulse Oximeter, Model N-395 · Nellcor Puritan Bennett, Inc. · 1999K982255 · Model 2000 Pulse Oximeter · Ivy Biomedical Systems, Inc. · 1998K973887 · Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and Cables · Masimo Corp. · 1998K962603 · Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & Cables · Masimo Corp. · 1997−50+5
  1. Root · 7 generations backK962603 Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & CablesMasimo Corp. · 1997
  2. 6 generations backK973887 Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and…Masimo Corp. · 1998
  3. 5 generations backK982255 Model 2000 Pulse OximeterIvy Biomedical Systems, Inc. · 1998
  4. 4 generations backK991823 N-395 Pulse Oximeter, Model N-395Nellcor Puritan Bennett, Inc. · 1999
  5. 3 generations backK012451 Propaq Encore Models 202, 204, 206; Propaq CS Models 242, 244, 246Welch Allyn Protocol, Inc. · 2001
  6. 2 generations backK032363 Zoll M Series Nibp OptionZoll Medical Corp · 2003
  7. 1 generation backK082599 Non-Invasive Continuous Blood Pressure Monitoring System Cnap…Cnsystem Medizintechnik AG · 2008
  8. This deviceK130709 Visi Mobile Monitoring SystemSotera Wireless, Inc. · 2013
  9. Descendant · cites it directly · 17 of its ownK143751 Visi Mobile Monitoring SystemSotera Wireless, Inc. · 2015
  10. Descendant · 2 generations on · 7 of its ownK150992 Vios Monitoring SystemVios Medical, Inc. · 2015
  11. Descendant · 2 generations on · 6 of its ownK150361 ViSi Mobile Monitoring SystemSotera Wireless, Inc. · 2015
  12. Descendant · 3 generations on · 4 of its ownK183067 Guardian Angel Rx GA2000 Digital Vital Sign Monitoring SystemTaiwan Aulisa Medical Devices Technologies, Inc. · 2019
  13. Descendant · 2 generations on · 4 of its ownK152341 ViSi Mobile Monitoring SystemSotera Wireless, Inc. · 2015

Showing 5 of 19 descendants. See all descendants

Descendants cleared per year

2015: 52018: 52019: 22021: 12022: 12023: 12024: 12025: 3
2015high 5 (2015) · low 0 (2016)2026

Most influential descendants

Showing 5 of 19 · See all
  • K143751Visi Mobile Monitoring SystemSotera Wireless, Inc. · 2015 · cites it directly17descendants
  • K150992Vios Monitoring SystemVios Medical, Inc. · 2015 · 2 generations on7descendants
  • K150361ViSi Mobile Monitoring SystemSotera Wireless, Inc. · 2015 · 2 generations on6descendants
  • K183067Guardian Angel Rx GA2000 Digital Vital Sign Monitoring SystemTaiwan Aulisa Medical Devices Technologies, Inc. · 2019 · 3 generations on4descendants
  • K152341ViSi Mobile Monitoring SystemSotera Wireless, Inc. · 2015 · 2 generations on4descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−7K962603Masimo Set MS-1 Pulse Oximeter & the Lnop Series of Sensors & CablesMasimo Corp.1997—
−6K973887Masimo Set MS-1P Pulse Oximeter and the Lnop Series of Sensors and CablesMasimo Corp.1998—
−5K982255Model 2000 Pulse OximeterIvy Biomedical Systems, Inc.1998—
−4K991823N-395 Pulse Oximeter, Model N-395Nellcor Puritan Bennett, Inc.1999—
−3K012451Propaq Encore Models 202, 204, 206; Propaq CS Models 242, 244, 246Welch Allyn Protocol, Inc.2001—
−2K032363Zoll M Series Nibp OptionZoll Medical Corp2003—
−1K082599Non-Invasive Continuous Blood Pressure Monitoring System Cnap Monitor 500I…Cnsystem Medizintechnik AG2008—
0 (this device)K130709Visi Mobile Monitoring SystemSotera Wireless, Inc.2013—
+1K143751Visi Mobile Monitoring SystemSotera Wireless, Inc.2015—
+2K150992Vios Monitoring SystemVios Medical, Inc.2015—
+2K150361ViSi Mobile Monitoring SystemSotera Wireless, Inc.2015—
+3K183067Guardian Angel Rx GA2000 Digital Vital Sign Monitoring SystemTaiwan Aulisa Medical Devices Technologies, Inc.2019—
+2K152341ViSi Mobile Monitoring SystemSotera Wireless, Inc.2015—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198710
198810
198910
199310
199410
199510
199620
199810
199910
200010
200220
200510
200720
200810
201210

Descendants by year cleared

Year clearedDevicesWith a Class I recall
201550
201850
201920
202110
202210
202310
202410
202530
FIG. 1 — Lineage of K130709, 1997–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MWI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MWI device

  1. #1 K230457 Empatica Health Monitoring Platform…score 28.0 · 39 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K112478Visi Mobile Monitoring SystemSotera Wireless, Inc.20122
*K082599Non-Invasive Continuous Blood Pressure Monitoring System Cnap Monitor 500I, 500AT
Summary page 1
…latory class 11 Predicate devices ViSi Mobile Monitoring System; KI 12478 (Clearance: 3/27/2012) CNAP Monitor 500i, 5O0at; K082599 (Clearance: 10/ 17/2008) Description The ViSi Mobile Monitoring System is a lightweight, body-worn vital signs…
Cnsystem Medizintechnik AG2008—

Also cleared against K112478: 2 other devices →

What descends from it? (19)

See all 19

3 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K143751Visi Mobile Monitoring SystemSotera Wireless, Inc.201517
K241728Vios Monitoring System (TM) Model 2050; Vios Central Station Monitor/Vios Central Server…Murata Vios, Inc.20250
K142827Visi Mobile Monitoring System, Visi Mobile Chest SensorSotera Wireless, Inc.20150

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 16 years and passes through 7 companies; a new generation was cleared every 2.0 years on median.
  • 3 of the 25 ancestors have a recall of any class.
  • Of its descendants, K143751 (Sotera Wireless, Inc., 2015) has gone furthest, with 17 descendants of its own.
  • 2 other devices also cite its predicate K112478.

How does its category compare?

All MWI devices

MWI Monitor, Physiological, Patient (Without Arrhythmia Detection Or Alarms): FDA decisions, review times, recalls and adverse event reports over 20 years. 2013, this device’s year, is highlighted.

FDA decisions per year · MWI

4in 2025

2007: 92008: 92009: 62010: 172011: 112012: 132013: 202014: 162015: 192016: 122017: 132018: 112019: 142020: 82021: 92022: 52023: 82024: 102025: 42026 (partial year): 6
2007high 20 (2013) · low 4 (2025)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MWI

247in 2025

2007: 42 days median2008: 49 days median2009: 112 days median2010: 58 days median2011: 78 days median2012: 104 days median2013: 85 days median2014: 148 days median2015: 127 days median2016: 165 days median2017: 205 days median2018: 217 days median2019: 255 days median2020: 138 days median2021: 161 days median2022: 231 days median2023: 250 days median2024: 202 days median2025: 247 days median2026 (partial year): 239 days median
2007high 255 (2019) · low 42 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MWI

9so far in 2026, the most since 2007

2007: 12008: 12009: 22010: 22011: 32012: 52013: 32014: 62015: 12017: 22019: 42022: 22024: 52026 (partial year): 9
2007high 9 (2026) · low 0 (2016)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MWI

182in 2025

2007: 32008: 32009: 202010: 172011: 162012: 312013: 422014: 302015: 312016: 512017: 852018: 1582019: 1692020: 1102021: 1882022: 1682023: 1792024: 1202025: 182
2007high 188 (2021) · low 3 (2007)2025

MAUDE reports naming product code MWI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200794213
200894913
20096112220
20101758217
20111178316
201213104531
20132085342
201416148630
201519127131
201612165051
201713205285
2018112170158
2019142554169
202081380110
202191610188
202252312168
202382500179
2024102025120
202542470182
202662399—

What is it indicated for?

The ViSi Mobile Monitoring System is intended for use by clinicians and medically qualified personnel for single or multi-parameter vital signs monitoring of adult (18 years or older) patients. It is indicated for ECG (3 or 5 leadwire), respiration rate, heart rate, non-invasive blood pressure (NIBP), continuous non-invasive blood pressure (cNIBP), non-invasive monitoring of functional oxygen saturation of arterial hemoglobin (SpO 2 ), pulse rate, and skin temperature in hospital-based facilities; including general medical-surgical floors, intermediate care floors, and emergency departments.

Continuous non-invasive blood pressure (cNIBP) testing has not been conducted on ambulatory patients.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K130709: Visi Mobile Monitoring System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K130709

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026